product

Product Category

loading

Anti-static clean workbench

Aili industrial anti-static clean workbench combines filtered air supply, static dissipation table and workstation grounding configuration, and is suitable for the assembly and inspection of static-sensitive electronic devices. It supports horizontal flow or vertical flow, table material, grounding method, filtration system and control function configuration, and can be customized according to device sensitivity and cleanliness requirements.

 
state:
quantity:

Aili industrial anti-static clean workbench

Configure clean and anti-static collaborative workstations for static-sensitive devices

On the basis of filtered air supply, the anti-static clean workbench is equipped with an electrostatic dissipation table, a grounding system and related electrostatic control measures to provide a clean operating environment for electrostatically sensitive electronic devices. Aili Industrial configures the table material, grounding structure, filtration system and control function according to the sensitivity of the device, fixture material, personnel grounding method and cleanliness target, so that cleanliness protection and static electricity control can be coordinated in the same work station.

Operation form

Airflow direction

Anti-static configuration

Custom support

Single or multi-person station

Horizontal or vertical flow optional

Static dissipative countertop and workstation grounding

Size, material and function customization

Features

Static Dissipative Countertops and Grounding Structures

Work surfaces can be made of static-dissipative materials that guide static charges to the ground through a grounding system. The table surface resistance and grounding resistance must be confirmed according to project requirements and verified through testing.

The grounding structure includes table grounding, personnel grounding and tooling grounding. The three should confirm the connection method and detection point respectively to avoid only grounding the tabletop and ignoring personnel or work equipment. Clean workbench classification and structural form can be viewed Clean Workbench Learn about different models.

Horizontal flow or vertical flow selected according to process

The anti-static clean workbench can select the airflow direction according to the workpiece shape and operation method. The horizontal flow passes through the work area from the rear to the front, which is suitable for workpieces with a relatively open windward surface; the vertical flow supplies air downward from the top, which is suitable for table operations and situations where the height of the workpiece is low.

The selection of airflow direction needs to be confirmed based on workpiece occlusion, operating actions and background conditions. The structural differences between the two airflows can be referred to How to choose between horizontal flow and vertical flow clean workbench? learn.

The synergy of anti-static and cleanliness

Particle control and static control in clean environments need to be considered simultaneously. Some anti-static materials may produce particles, and certain cleaning methods may affect the resistance of the countertop. Both should be checked together when selecting.

Personnel grounding, anti-static clothing, ionization equipment and operating procedures also affect workstation static levels and should be confirmed together with clean operating procedures.

Table load and process interface

The load capacity of the tabletop needs to be checked based on the weight of the workpiece, fixture and instrument. For heavier concentrated loads, the support position and local reinforcement method should be confirmed. The tabletop can be equipped with threading holes, tooling fixing positions and accessory interfaces as required.

When it is necessary to install tooling or supporting equipment, the fixed hole positions, threading positions and accessory interfaces can be communicated. The countertop material, thickness and support spacing can be confirmed according to project requirements.

Fan and filter matching

Match the fan, motor and air duct according to the air supply area, filter resistance and target wind speed, taking into account the effective working area and operation adjustment requirements.

Filter selection needs to jointly clarify efficiency, size, installation sealing and replacement methods. Related configurations can be found HEPA and ULPA filters , select supporting products based on particle control requirements and system resistance.

Working principle

After the air is initially filtered, it is sent to the filtration system by the fan, and then enters the work area through the final high-efficiency filter. The horizontal flow model supplies air from the rear to the front, while the vertical flow model supplies air downward from the top. The airflow passes through the operating area and is discharged along the designed path.

Air enters→primary filter→fan supply→end high-efficiency filter→work area air supply→air discharge

Static control is achieved through grounding of countertops, personnel, and work equipment. During operation, human movements, tools and larger workpieces may change the local airflow. The performance of the work area should be checked based on the actual placement and working status.

Technical parameters and configuration

project

Configuration instructions

Product form

Anti-static clean workbench

Airflow direction

Horizontal flow or vertical flow, confirmed according to process

operating position

Single or multiple workers, configured according to the plan

Work area size

Confirm based on workpiece, tool and personnel operating scope

effective working depth

Determine based on workpiece position and air supply coverage

clean target

It can be configured according to the ISO level 5 work area target, and accepted according to the agreed particle size and testing status.

Anti-static configuration

Static dissipation countertop, countertop grounding, personnel grounding and tooling grounding are confirmed according to the project

Filtration system

Primary effect and terminal high efficiency filter matching

Working wind speed

Configure according to process requirements, and the speed adjustment range is confirmed according to the selected plan

Countertop and cabinet

Material, load-bearing and surface treatment are confirmed according to the project

fan drive

Configure according to air volume, resistance and speed adjustment requirements

Control function

Start/stop, speed adjustment, lighting and status display configured on demand

Process interface

Sockets, wiring holes and tooling fixing positions can be configured as needed

Power and power

Confirm by selected model and electrical requirements

Test items

Wind speed, particle concentration, filter leak detection, electrical inspection and static electricity related inspections are carried out as agreed.

Filter efficiency and work area cleanliness are different indicators, and equipment performance needs to be confirmed through complete machine testing. The difference between cleanliness level and filtration efficiency can be found in What is the difference between cleanliness level and filtration efficiency?。

Application scenarios

Electronic component assembly

Semiconductor device operations

Optical component handling

Instrument component assembly

Static sensitive device assembly

Precision electronic inspection

Static sensitive cleaning station

Clean handling of non-hazardous materials

Clean benches are mainly used for product protection and do not provide the personnel and environmental protection that biological safety cabinets have. When infectious materials, toxic volatiles, or other hazardous materials are involved, equipment should be selected based on the risk.

Anti-static work station selection and layout

Confirm device sensitivity and static electricity control requirements

Different devices have different sensitivity to static electricity. The device withstand voltage, operating environment and protection level should be confirmed. Determine the table resistance, grounding method and personnel protection measures according to the degree of sensitivity.

Check the grounding of countertops, personnel and work equipment

The connection methods and detection points for table grounding, personnel grounding and tooling grounding should be confirmed respectively. The grounding system needs to be tested regularly to ensure reliable connections.

Pay attention to the compatibility of anti-static materials and cleanliness

Anti-static materials may produce particles or affect cleaning methods. Cleaning requirements and static electricity control should be confirmed together when selecting. Certain cleaners may affect countertop resistance and compatibility should be confirmed.

Reserve space for maintenance and air intake

Space needs to be reserved for air inlet, filter replacement and fan maintenance at the rear of the equipment. When installing against a wall or side by side, make sure that the maintenance channel can be opened normally.

Routine maintenance

Clean the countertop, side enclosures and operating area according to process requirements to avoid residues affecting subsequent operations. After cleaning, the resistance and grounding status of the table should be confirmed.

Regularly check ground connections, table resistance, and personnel grounds. Maintain the primary filter according to the usage environment, and determine the maintenance needs of the terminal filter based on pressure difference, operating wind speed, cleanliness testing and filter status. After replacement, the installation seal and related performance should be rechecked.

The synergistic advantages of the entire industrial chain of Aili Industry

Aili Industrial has a manufacturing base of 30,000 square meters, covering R&D and manufacturing links such as motors, fans, control systems, sheet metal, air filters and complete machine assembly.

For anti-static clean workbench projects, the table material, grounding structure, support frame, filter area, fan operating point and control function can be checked together to support product selection, non-standard design and batch project matching.

manufacturing link

Project support

Motors and fans

Matching clean workstation air supply, filter resistance and speed adjustment requirements

air filter

Check efficiency, effective dimensions and installation sealing

control system

Configure start/stop, speed adjustment, lighting and operation display

Sheet Metal and Structure

Implement table tops, ground structures, supports and process interfaces

Complete machine assembly and testing

Organize production and inspection according to confirmed drawings and technical requirements

FAQ

What is the difference between an anti-static clean workbench and an ordinary clean workbench?

The main differences are in the countertop material and grounding configuration. The anti-static workbench is equipped with a static dissipative tabletop and grounding system, which is suitable for the operation of electrostatic-sensitive devices.

Are table grounding and personnel grounding the same thing?

no. The connection methods and detection points need to be confirmed separately for table grounding, personnel grounding and tooling grounding. The three together constitute workstation static electricity control.

Will anti-static surfaces affect cleanliness?

Both material particle release and cleaning methods need to be confirmed. Compatibility of anti-static materials with cleanliness requirements should be checked during the selection stage.

Can I just do anti-static on the countertop?

It should be confirmed based on the sensitivity of the device and the mode of operation. Personnel grounding and work equipment grounding also affect the level of static electricity at the workstation, and it is recommended to evaluate them together.

How often should the filter be replaced?

It should be combined with pressure difference, wind speed, cleanliness detection and filter status judgment. Recheck sealing and related performance after replacement.

Anti-static clean workbench selection and technical consultation

Clarifying device sensitivity, static control requirements, workpiece size, airflow direction and cleaning goals will help determine the anti-static work station configuration suitable for the actual process.

Contact us immediately to obtain product information and technical parameters of anti-static clean workbench.

→ Consult anti-static configuration and work area dimensions → Submit device sensitivity and process requirements
→ Learn about filtering and speed regulation configuration → Communicate about non-standard and equipment matching

pass Aili Industrial Technology Consulting , communicates product selection and customization needs.

Aili Industry - From core components to complete clean workbench machines, it provides products and technical support for the assembly of electrostatically sensitive devices, precision inspection and anti-static workstations.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.