product

Product Category

loading

Multi-person double-sided operation clean workbench

Aili industrial multi-person double-sided operation clean workbench is oriented to multi-person collaboration and continuous process layout. It adopts a wide working area, open operations on both sides and a top vertical air supply structure to provide a local clean environment for assembly, inspection, sorting and material handover. The structure of the equipment can be determined according to the size of the workpiece, the number of workstations on both sides, the load capacity of the table and the installation conditions, and can be combined with filtration, fans and control configurations to form a supporting solution.
Status:
Quantity:

Aili industrial multi-person double-sided operation clean workbench

Equipped with double-sided clean air supply for wide-width workstations and multi-person collaboration

The multi-person double-sided operation clean workbench arranges operating positions on both sides of the equipment, and the filtered air at the top passes downward through the work area. According to the needs of multi-person collaboration, process connection or material handover, Aili Industrial plans the areas for people, workpieces, tools and materials on both sides to match the wide working area with the vertical air flow direction.

Operation form

Airflow direction

Workstation layout

Support

Multi-person two-sided operation

Top vertically downward

Wide workstations or collaboration areas

Size, structure and function customization

Features

Effective operating space for multiple people on both sides

Determine the effective width of each workstation based on the number of people on both sides, workpiece size and tool occupancy range, and arrange a shared tool area and material temporary storage area.

Continuous processes need to clearly define the handover location to reduce cross-station movements of personnel and mutual interference between tools. When multiple people operate the same workpiece together, the station position, fixture and workpiece movement path need to be checked.

Wide top vertical air supply

According to the number, arrangement and air duct structure of the filters configured in the long work area, check the air supply performance on both sides, the middle and near the filter joints.

The actual air flow at each workstation is related to the filter layout, internal air ducts and workpiece shielding. It needs to be checked based on different positions and cannot be judged only by the total air volume.

Long table support and load-bearing

Check the total table load, local concentrated load and support spacing together. For wider workpieces, the fixing and moving positions of the fixture and load changes during operation should be clarified.

The countertop material, surface treatment, fixed interfaces and support methods can be configured according to the process, taking into account load-bearing, cleaning and daily maintenance.

Fan and filter coordinated matching

Check the effective filtration area, filter resistance, air duct loss and operating wind speed together, and then determine the number of fans and drive configuration.

Related filtering products can be viewed HEPA and ULPA filters , confirm efficiency, sealing and maintenance methods according to project requirements.

Unified operation or partition configuration

Evaluate unified operations or zoning controls based on how workstations are used. The zoning function requires corresponding air supply structure support, and the impact of different opening combinations on adjacent workstations should be checked.

The specific plan should be confirmed together to match the control method with the air flow organization, detection conditions and actual use process.

Working principle

After the air passes through the primary filter, it is sent into the filtration system by the fan, then passes through the high-efficiency filter at the top and end, passes downward through the operating positions on both sides, and leaves the work area along the designed path.

Air enters → primary filter → fan air supply → top high-efficiency filtration → multi-station vertical air supply on both sides → air discharge

Workpieces, instruments, and personnel movements may block vertical airflow, and particles generated by operations may also affect adjacent locations. Placement and handover should be planned according to the actual operation, and the airflow performance in key operating areas should be checked.

Technical parameters and configuration

project

Configuration instructions

Product form

Multi-person double-sided operation clean workbench

operating position

Multiple people operating on both sides of the work area

Airflow direction

The top blows air downward vertically

Number of workstations

Determined according to process, personnel spacing and effective operating width

Work area size

Configure according to workpiece, tools, materials and operating range on both sides

effective working depth

Combining airflow coverage with actual workpiece position confirmation

clean target

It can be configured according to the ISO level 5 work area target, and accepted according to the agreed particle size and testing status.

Filtration system

The primary effect is matched with the top-end high-efficiency filter, and the quantity and arrangement are determined according to the plan.

Wind speed and uniformity

Confirm according to process requirements and check the positions of different workstations on both sides

Countertop support

The total load, local load and support spacing are checked according to the project

fan drive

Configure according to air volume, resistance, air duct and control requirements

Control method

Unified operation or partitioned control supported by architectural design

Process interface

Sockets, wiring holes, tooling fixation and equipment interfaces can be configured as needed

Overall machine size

Determine based on transportation, approach, installation and maintenance space

Power and power

Confirm according to selected configuration and actual operating conditions

Test items

Wind speed, particle concentration, filter leak detection and electrical inspection are carried out as agreed.

Filter efficiency and work area cleanliness are different indicators, and equipment performance needs to be confirmed through complete machine testing.

Application scenarios

Multi-person collaborative assembly

Precision component inspection

Wide workpiece handling

Optical component assembly

Connection of processes on both sides

Material handover processing

Tooling and equipment matching

Clean handling of non-hazardous materials

Clean benches are mainly used for product protection and do not provide the personnel and environmental protection that biological safety cabinets have. When infectious materials, toxic volatiles, or other hazardous materials are involved, equipment should be selected based on the risk.

Selection and layout of multiple workstations

Determine the length of the work area by process

First record the tools, workpieces and personnel operating range required for each process, and then determine the number and total length of workstations. Shared tools, material staging and handover areas should also be factored into the layout.

Check for occlusion and downstream effects

Large work equipment, monitors or instruments should not block the direct air supply to key operating positions. Operations that may generate particles, such as unpacking and friction, should be arranged in conjunction with the direction of air flow and the location of sensitive workpieces.

Check transportation and on-site installation

Longer equipment requires confirmation of packaging dimensions, handling door openings, turning channels and on-site installation conditions.

When using segmented delivery, the connection, sealing, positioning and on-site inspection requirements should be clarified in advance, and the smoothness and support status of the table after installation should be checked.

Clarify operational and acceptance status

Agree on the detection range at each work station, near the filter joints and at the actual operating position.

When the partition is running, the expected opening combination should be checked, and the detection results when all areas are turned on cannot be used instead of other operating states.

Routine maintenance

Keep the air inlet and filter outlet areas clear, and clean the countertop, side enclosures and workstation connection locations according to process requirements.

Schedule maintenance based on differential pressure, air velocity, cleanliness testing and filter status. After replacing the end filter, the installation seal and related performance should be rechecked.

The synergistic advantages of the entire industrial chain of Aili Industry

Aili Industrial has a manufacturing base of approximately 30,000 square meters, covering R&D and manufacturing links such as motors, fans, control systems, sheet metal, air filters, and complete machine assembly.

For multi-person double-sided operation workbench projects, the filter layout, fan working point, long table support, process interface and operation control can be matched together to support non-standard design and batch project matching.

manufacturing link

Project support

Motors and fans

Matching wide air supply, system resistance and operation requirements

air filter

Configure filter arrangement, sealing and replacement methods

control system

Match unified operation or partition control requirements

Sheet metal and countertops

Realize long table top, double-sided opening and process interface

Complete machine assembly and testing

Organize production and inspection according to confirmed drawings and technical requirements

FAQ

What processes are suitable for multi-person double-sided workbenches?

It is suitable for occasions such as multi-person collaborative assembly, wide-width workpiece operation, process connection on both sides or material handover, etc. that require access to the work area from both sides. The actual configuration needs to be confirmed based on the workpiece size, personnel movements and on-site space.

Will operating both sides affect the airflow?

Personnel movements, material volumes, and external cross-air flows can all affect the work area. Actual usage conditions should be confirmed through reasonable layout, operating procedures and agreed testing.

Can only some workstations be opened?

Corresponding zoning structures and control schemes are required, and the impact of operating combinations on adjacent areas is checked.

Can the countertop and size be customized?

The requirements can be put forward based on the workpiece size, load-bearing capacity, operating height and installation space, and the filter layout, table support and maintenance space can be checked simultaneously.

Do you need UV light?

It should be evaluated according to actual process and management requirements. UV lamps cannot replace filtered air supply, cleaning and necessary testing; if optional, the usage procedures and protective measures should be confirmed at the same time.

Selection and configuration consultation

Provide process information

Confirm configuration plan

Workpiece size, movements on both sides, number of operators

Confirm valid workspace

Cleanliness requirements, installation environment, maintenance conditions

Confirm filtering and structure

If multiple people are required to operate the clean workbench on both sides, the workpiece size, process description and on-site layout can be submitted to communicate the applicable size, filtration system and operating configuration.

→ Consult multi-station dimensions and layout → Submit artifacts and tool occupancy
→ Learn about filtering and running configuration → Communicate about non-standard and production line matching

pass Aili Industrial Technology Consulting , communicates product selection and customization needs.

Aili Industry - From core components to complete clean workbench machines, it provides products and technical support for multi-person collaborative assembly, precision inspection and wide-width workpiece operations.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.