ULPA ultra high efficiency filter

U15, U16, U17 grades, for local clean air supply in clean rooms and equipment

Aili Industry provides ULPA ultra-high efficiency filters, which can be selected according to the filtration level, installation size, rated air volume, resistance and sealing requirements of the project, and are equipped with FFU, EFU and other clean air supply equipment. The filter material can be glass fiber or PTFE. The specific configuration and performance are subject to the specifications and test reports of the corresponding model.


Please provide equipment drawings or existing filter parameters to confirm the installation interface, air volume and filter configuration.

05-ULPA-Filter-ULPAchaogaoxiaoguolvqi-AILIGY
View product categories → Submit selection parameters →
namecontentnamecontent
filter levelU15, U16, U17filter materialGlass fiber, PTFE
structureNo partitions, dense pleat typesizeStandard specifications, non-standard customization
Sealing methodGasket seal, liquid tank sealInstallation interfaceMatch according to the box body and knife edge interface
Supporting equipmentFFU, EFU, BFUapplication systemClean air supply terminal and equipment local clean system
Selection parametersAir volume, resistance, filtration levelTesting requirementsEfficiency testing, scanning leak detection

What is ULPA ultra-high efficiency filter?


ULPA is an ultra-low penetration air filter, used in clean environments and equipment that have high requirements for the control of particulate matter in the air.

Classified according to EN 1822, ULPA includes U15, U16 and U17. The grade judgment should be combined with the test results under the most penetrating particle size (MPPS), and should not just look at the efficiency promotion value of a fixed particle size.


In addition to filtration efficiency, you also need to confirm the actual operating air volume, pressure drop, installation sealing and leak detection requirements when selecting a model.


How to choose U15, U16 and U17 ULPA ultra-high efficiency filters?

filter levelThe lowest overall efficiency under MPPSImportant points to confirm when selecting
U15≥99.9995%Whether it meets the process requirements and the resistance under the target air volume
U16≥99.99995%Particle control requirements, fan residual pressure and leak detection conditions
U17≥99.999995%Whether there are indeed requirements for this level, and the verification capabilities of the whole machine

The above is the overall efficiency classification value of EN 1822; overall efficiency and local efficiency are different detection indicators. ,

The grade should be determined by process requirements. After confirming the target level, match the filter area, filter material, thickness and fan operating point to avoid being unable to maintain the required air volume after the filter is installed.

Introduction to other air filters from Aili Industrial

HEPA high efficiency filter

Covering H13 and H14 levels, it can be used in clean rooms, AHU, FFU and other clean air treatment equipment. Glass fiber or PTFE filter material can be selected according to the project.

Grade: H13/H14


View HEPA filters→

ULPA ultra high efficiency filter

Covering U15, U16, and U17 grades, it is designed for clean environments with high particle control requirements. The size and sealing form can be configured according to the equipment interface.

Grade: U15/U16/U17


View ULPA filters →


High efficiency filter without partition

Adopting a dense pleated filter material and glue line separation structure, the filter area can be arranged within the corresponding thickness and used for FFU, EFU, clean equipment and terminal air supply.

Structure: Mini-pleat


View HEPA products →

PTFE HEPA/ULPA filter

Using PTFE membrane filter material, it can be configured with HEPA or ULPA grade according to cleanliness requirements. Material suitability needs to be confirmed in conjunction with humidity, chemical media and complete filter components.

Filter material: PTFE


View PTFE products →

V type high air volume high efficiency filter

Multiple filter elements are combined in a V-shape to arrange a larger filter area in the box space, and are used in systems that require larger air treatment capacity.


Structure: V-Bank


View V-shaped products →

Large air volume box type high efficiency filter

Using box-type or V-shaped filter element combination, the specifications can be confirmed according to the design air volume, installation space and allowable resistance of the air handling equipment.


Direction: Larger air handling capacity


View box products →

Liquid tank seal high efficiency filter

The liquid tank and the knife edge cooperate to form an installation seal, which is used in clean systems where it is important to confirm the sealing connection between the filter and the installation frame.

Seal: liquid tank/knife edge


Submit Sealing Request→

Non-standard HEPA/ULPA filter

Non-standard product configurations can be communicated based on equipment space, size, air volume, resistance, frame, filter material and sealing interface.


Scope: Dimensions match structure


Submit custom parameters →

Select ULPA ultra-high efficiency air filter according to equipment and installation requirements


Selection directionConditions that need to be confirmed
FFU matching ULPA filterModule size, target air volume, fan residual pressure, installation and replacement methods
EFU matching ULPA filterEquipment interface, local air supply range, thickness restrictions and maintenance space
Glass fiber filter material ULPA filterOperating air volume, pressure drop, ambient temperature and humidity and process material requirements
PTFE filter material ULPA filterProcess suitability and overall suitability of media, adhesives, frames and seals
Non-standard size ULPA filterOverall dimensions, effective filtration area, installation tolerances and sealing interfaces
Confirmation methodSubject to specifications and testing data
Selection conclusion: First determine the filtration level based on the cleanliness level, process requirements and acceptance standards, and then complete the product configuration based on the system air volume, fan static pressure, installation space and sealing interface. If the same project includes FFU, EFU or HEPA BOX, it is recommended to confirm the filter and equipment parameters simultaneously.

What cleaning scenarios are ULPA filters used for?

ULPA filters can be used for particle control in high-tech clean rooms, clean workbenches and clean air equipment.


For FFU, EFU or local clean areas inside the equipment, you should first clarify:
-Which area needs protection and the corresponding particle control target.
- The air supply volume or face velocity to be maintained.
- Filter size and resistance allowed by the device.
- How to check sealing, air speed and cleaning performance after installation.


The cleanliness level needs to be verified through the actual environment or equipment and cannot be determined solely by the filter level.

ULPA filter selection steps

stepSelection contentInformation that needs to be confirmed
1. Clear cleaning goalsDetermine filter levelSelect U15, U16 or U17 according to process requirements, and clarify testing and acceptance requirements
2. Confirm installation dimensionsMatch device spaceCheck the filter length, width, thickness, installation tolerance and replacement space
3. Determine the operating air volumeMatch air supply needsProvide rated air volume or target surface wind speed, combined with effective air outlet area for confirmation
4. Check system resistanceMatch fan capacityConfirm the initial resistance under the target air volume, and check the fan residual pressure under the final resistance condition
5. Select filter media and sealingAdapt to the use environmentAccording to the temperature and humidity, process medium and installation interface, confirm the filter material, frame and sealing method
6. Clear testing and acceptanceVerify actual performanceAgree on efficiency testing, scanning leak detection and reporting requirements, and verify sealing and air supply performance after installation

What parameters need to be provided for ULPA filter selection?

parameterPlease provide information
Use locationClean room, FFU, EFU, clean bench or other equipment
filter levelU15, U16, U17, or the testing requirements specified by the project
Overall dimensionsLength × width × thickness, indicate unit and allowable deviation
Operating air volumeAir volume of a single device or target surface wind speed
Resistance requirementsAllowable initial resistance, final resistance or fan residual pressure under corresponding air volume
Installation methodPressed, embedded or other structures, attached installation diagram for easier confirmation
Sealing interfaceGasket, tank or equipment specified construction
Usage environmentTemperature, humidity, and possible exposure to process media
Testing requirementsEfficiency, scanning leak detection, on-site acceptance and reporting requirements
Purchasing informationQuantity, lead time and replacement parts requirements

Aili Industrial's synergistic advantages across the entire industry chain


Aili Industry focuses on the R&D and manufacturing of purification equipment, air filtration equipment, clean room equipment and air treatment equipment, with a 30,000 square meter production base. The manufacturing system covers motors, fans, filters, control systems, sheet metal processing, complete machine assembly and product testing, and forms a product system from core components to complete machine equipment.
For ULPA projects, this product and manufacturing coverage allows filtration levels, air volumes, static pressures, installation dimensions, sealing interfaces and equipment controls to be checked under the same project conditions. The filter can also be matched with products such as FFU, EFU, BFU, HEPA BOX, clean room equipment and air conditioning boxes.
Aili Industrial Motor R&D and Production(1)(1)

Fan and motor matching

For FFU, EFU, BFU and other equipment, check the filter resistance, design air volume and fan static pressure conditions together.


Related: air volume, static pressure, filter resistance

Aili Industrial Intelligent Group Control System

Control system collaboration

Equipment projects can simultaneously confirm speed regulation, operation control and communication requirements, so that filters and air supply equipment can communicate according to the same working conditions.


Related: Equipment operation and control requirements

Aili Industrial FFU production sheet metal production

Sheet metal and structural processing

The box, frame and related structural parts can be confirmed according to the installation space and equipment interface, and manufacturing support is provided for standard and non-standard sizes.

Related: Dimensions, interfaces, installation structures

Aili Industrial FFU high-efficiency filter production workshop

Filter independent production system

Covering HEPA, ULPA and other air filtration products, the grade, filter material, size, frame and sealing method can be confirmed by project.


Related: Filter production and project selection

Aili Industrial Filter Testing

Assembly and process inspection

Quality inspection covers core components, production processes and complete machine assembly, and corresponding inspections are carried out according to product type.


Associations: parts, processes, assemblies

Aili Industrial FFU strict testing

Product testing and delivery

Conduct corresponding performance and operational tests based on product type, and confirm specifications, materials, packaging and delivery arrangements based on project requirements.

Related: testing, information, packaging, delivery


The value of collaboration across the entire industry chain is not to emphasize a single component alone, but to match filters, fans, structures and control parameters in the same project based on actual system conditions. The final configuration is still subject to the technical specifications, drawings and testing data confirmed by both parties.

Project support advantages for large factories


Aili Industry has a 30,000-square-meter production base. The production area covers motors, fans, filters, control systems, sheet metal processing, complete machine assembly, product testing, and finished product management. For HEPA and ULPA filter projects, complete site and manufacturing zoning provide the organizational basis for raw material entry, filter production, structural component processing, process inspection, finished product storage and packaging delivery.


The project value of large-scale production bases is mainly reflected in multi-category collaboration, parallelization of standard and non-standard products, batch project organization, and supporting communication of filters and clean equipment.

Aili Industrial 30,000 square meters modern industrial plant

ULPA filter inspection and acceptance

When purchasing, the filter model, serial number, test air volume, efficiency level and test report should be matched.

It is recommended to specify in the order:

- The testing standards and acceptance indicators adopted.

- Efficiency testing and scanning leak detection requirements.

- The test air volume corresponding to the resistance data.

- Test reports, serial number labels and packaging requirements.

- Responsibility for equipment or site acceptance after installation.

The installation acceptance should also check the interface sealing and actual operating performance.

ULPA Filter FAQ

From product selection, performance configuration to customized development, the following are the most common issues that customers are concerned about when selecting ULPA filters.

Q1: What is the difference between ULPA and HEPA filters?

A: According to EN 1822 classification, HEPA includes H13 and H14, ULPA includes U15, U16, and U17. The allowable particle penetration rate of ULPA is lower. When selecting a model, you should also compare the resistance and equipment suitability of the specific model under the same air volume.

Q2: Can FFU replace the H14 filter with U15?

A: You need to first check the size, sealing interface, and whether the fan can maintain the target air volume under the resistance of the new filter. After completion of replacement, wind speed, leakage and cleanliness performance should be verified according to project requirements.

Q3: Is U16 definitely more suitable for equipment than U15?

A: Not necessarily. If the process requires U16, it should be configured as U16; if U15 meets the requirements, it needs to be judged based on air volume, energy consumption and maintenance costs. Simply improving the level cannot replace complete machine performance verification.

Q4: What is the initial resistance of the ULPA filter?

A: There is no unified value. The initial resistance is related to the filter material, filter area, structure and test air volume. When enquiring, please provide the resistance data of the 'specific model at the specified air volume' upon request.

Q5: How often should the ULPA filter be replaced?

A: It should be determined based on pressure difference changes, actual air volume, leakage inspection, process requirements and maintenance records. You cannot judge whether replacement is needed based on a fixed month alone.

Q6: Can the ULPA filter be used again after cleaning?

A: Do not wash, purge or brush the filter material yourself. Check the maintenance instructions of the corresponding model first; if there is no clear cleaning and re-verification procedure, it should be managed as replacement parts.

Q7: Can ULPA filters remove odors and gaseous pollutants?

A: ULPA is mainly used for particle filtration. Odor and gas pollutants require corresponding gas phase filtration solutions according to the type of pollutants.

Q8: What do I need to provide for customized ULPA filters?

A: Provide at least the filtration level, size, air volume, resistance limit, sealing method, usage environment and quantity. Attached equipment drawings or old filter reports can more accurately confirm the configuration.

Q9: How to choose glass fiber and PTFE filter materials for ULPA filters?

A: The filtration efficiency, resistance and usage environment suitability of specific models under the same air volume should be compared, and the material requirements of the process should be checked at the same time. When high humidity or chemical media are involved, the suitability of frames, adhesives and seals also needs to be confirmed. Aili Industrial can assist in selecting fiberglass or PTFE configuration based on working conditions and equipment parameters.

Q10: What is the relationship between Aili Industrial’s entire industry chain manufacturing and the ULPA ultra-high-efficiency filter project?

A: Aili Industrial's manufacturing system covers motors, fans, filters, control systems, sheet metal, assembly and testing, etc., making it easy to simultaneously check relevant parameters in projects including FFU, EFU, BFU or air treatment equipment.


Not sure which ULPA air filter is right for your application?

Customized air filter solutions for your special needs

Provide your installation dimensions, air volume/wind speed requirements and usage environment, and the Aili industrial engineering team can assist you in matching the solution.

Want to know more about the technical issues of ULPA air filters?

View more selection and technical issues of ULPA ultra-high efficiency filters to obtain more complete air filter knowledge and solutions.
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.