product

Product Category

loading

Double single-sided vertical flow clean workbench

Aili Industrial's two-person single-sided vertical flow clean workbench provides a local clean operating space for two people to work on the same side through high-efficiency filtration at the top and downward air supply. The product is configured around double work station width, workpiece placement, tool use and material transfer. It is suitable for precision parts assembly, electronic component inspection, optical component operation and non-hazardous material clean operation. The work area size, table structure, filtration system and control functions can be customized according to site conditions.

 

state:
quantity:

Aili industrial double single-sided vertical flow clean workbench

Two people operating on the same side, matching assembly and inspection processes

Two people operate on the front side of the equipment, and can arrange parallel or collaborative work stations according to the process. The design of the work area needs to take into account the distance between personnel, the range of elbow movement, the width of tooling and the temporary storage location of materials, so that the effective operating space matches the actual operating needs.

For workstations that combine assembly and inspection, tools and materials can be divided into areas by process, and the handover path between two people can be clarified to reduce repeated actions across workpieces.

Operation form

Air supply direction

Workstation layout

Custom support

Two people operating on the same side

Top vertically downward

Parallel or collaborative work

Dimensions, structure and functional configuration

Features

Top vertical air supply

The terminal filter is located above the work area, and clean air passes downward through the operating area. Match the air supply coverage according to the width and depth of the double work station, and check the obstruction of the air flow by the workpiece, fixture and instrument.

During operation, items should be placed reasonably to keep the air supply and air discharge positions clear, and avoid large tools or materials from blocking the work area for a long time.

Double workstation and table configuration

Configure the work area size, table height, load bearing and tool positions according to independent or joint operation requirements. When placing large workpieces or heavier instruments, the table support and operating margin need to be checked simultaneously.

The stainless steel countertop is convenient for daily wiping and surface inspection, and can communicate with tool fixing, threading and accessory interfaces according to the process.

Matching fan and filtration system

Match the fan and motor according to the effective air supply area, filter resistance and working wind speed, and configure it in combination with the air duct and static pressure box structure.

Filter selection also requires clear filtration efficiency, sealing method and replacement space. You can learn more about Aili IndustrialHEPA and ULPA air filters .Complementary products for

Wind speed adjustment and operation control

Fan start and stop, wind speed adjustment, lighting and operating status display can be configured as needed. For workstations that run for a long time, the energy consumption can be evaluated based on DC or EC drive solutions, actual wind speed and usage time.

Matching electrostatic and vibration requirements

For electronic components that are sensitive to static electricity, grounding, anti-static floors and static elimination configurations can be communicated; for detection operations that are sensitive to vibration, independent table support and vibration isolation measures can be evaluated.

Relevant functions should be confirmed together with site conditions and process requirements.

Working principle

After the air is initially filtered, it is sent into the filtration system by the fan, and then passes through the terminal high-efficiency filter and is sent downward from the top of the work area to provide clean air for the designated operating position.

Air enters → primary filter → fan supply → terminal high-efficiency filter → vertical air supply in the work area → air discharge

The cleanliness performance of the work area is determined by the filter, installation seal, wind speed, air flow organization and actual operating conditions. The movements of two people and the placement of workpieces may change the local air flow, and the operating area should be planned based on the actual process.

Technical parameters and configuration

project

Configuration instructions

Product structure

Two-person single-sided operation, vertical air supply from the top

Work area size

Confirm based on the workpiece, tool and the operating range of two people

Overall machine size

Determine based on installation space, access channel and maintenance requirements

clean target

It can be configured according to the ISO level 5 work area target, and accepted according to the agreed particle size and testing status.

Filtration system

The primary effect is matched with the terminal high-efficiency filter

Filter configuration

Efficiency level, size and sealing method are confirmed by project

Working wind speed

According to the process configuration, the speed adjustment range is confirmed according to the selected plan.

work surface

Stainless steel countertop, load-bearing and supporting structure determined according to project

fan drive

Configure AC, DC or EC solutions according to air volume, resistance and operation requirements

Control function

Start/stop, speed adjustment, lighting and status display configured on demand

Condition monitoring

Configure differential pressure or wind speed monitoring as needed

Additional features

Static control, independent countertop, socket and tooling interface can be configured in communication

Power and power

Confirm according to selected model and project electrical requirements

Test items

Carry out wind speed, particle concentration, filter leakage and electrical inspections as agreed

Work area cleanliness and filter efficiency are different indicators and need to be confirmed based on the air flow, sealing and test results of the entire machine. Related levels and testing concepts can be viewedISO cleanliness grade comparison and explanation。

Application scenarios

Electronic component assembly

Precision parts inspection

Optical component handling

Instrument component assembly

Two people working side by side

Assembly and inspection collaboration

Cleaning parts operations

Clean handling of non-hazardous materials

Clean benches are mainly used for product protection and do not provide the personnel and environmental protection that biological safety cabinets have. When infectious or hazardous materials are involved, equipment should be selected based on the operational risks.

Key points for selecting a double clean workbench

Make it clear how the two of you will work

First determine whether the two people operate different workpieces independently or complete the assembly and inspection of the same workpiece together, and then determine the workstation width, tool position and material transfer method.

Check the space occupied by workpieces and tools

In addition to the size of the workpiece, space for fixtures, instruments, tools and materials needs to be taken into account. After placing taller workpieces or instruments, check the top air supply blockage and surrounding airflow.

Clarify cleaning and acceptance requirements

Determine the particle size of concern, working area level and detection status, and then jointly check the filtration configuration, working wind speed and sealing requirements.

Plan installation and maintenance locations

Check the transportation aisle, installation clearance, power supply, air inlet location and filter replacement space. Reduce the impact of door airflow, direct air conditioning blowing and frequent personnel movement on the work area.

Routine maintenance

Keep the air inlet and air outlet positions clear, and clean the work area and primary filter according to usage.

Schedule maintenance based on differential pressure, operating air speed, particle detection and filter status. If the filter is found to be damaged, leaking, or the performance cannot meet the requirements, it should be dealt with in time; after replacing the end filter, recheck the sealing and related performance.

The synergistic advantages of the entire industrial chain of Aili Industry

Aili Industrial has a manufacturing base of 30,000 square meters, covering R&D and manufacturing links such as motors, fans, control systems, sheet metal, air filters and complete machine assembly.

For the two-person clean workbench project, the workstation layout, air supply area, filter resistance, table bearing and control configuration can be checked in the same plan, supporting non-standard design and batch project matching.

manufacturing link

Project support

Motors and fans

Match air supply, resistance and speed regulation requirements

air filter

Check efficiency, sealing and maintenance methods

control system

Configure operation control and status display

Sheet metal and countertops

Realize double workstation, load-bearing and interface structure

Complete machine assembly and testing

Organize production and inspection according to confirmed drawings and technical requirements

FAQ

What is the difference between two-person single-sided and double-sided operation?

Double-sided means that two people are operating on the same side; double-sided means that there are operating positions on both sides of the equipment. Selection should be based on personnel location and material flow direction.

Will two people operating at the same time affect the airflow?

Personnel movements and workpiece obstructions may alter local airflow. The locations of work stations, tools and materials should be reasonably divided, and the performance of the work area should be checked based on actual operating conditions.

Can the workspace size be customized?

The design can be combined with the workpiece, tooling and operating margin, and the filter coverage, table load-bearing and overall machine installation dimensions can be checked at the same time.

Can DC or EC fans be used?

DC or EC solutions can be matched according to air volume, filter resistance, speed regulation and energy consumption requirements. The specific configuration is confirmed in the technical requirements.

How often should the filter be replaced?

The operating environment, pressure difference, wind speed, cleanliness detection and filter status judgment should be combined. Actual inspections cannot be replaced by fixed cycles only.

Double clean workbench selection and technical consultation

Clarifying the workpiece size, two-person operation method, cleanliness target and on-site space will help form a product solution suitable for the actual process.

Contact us now to obtain the product information and technical parameters of the double-person single-sided vertical flow clean workbench.

passAili Industrial Technology Consulting , communicates product selection and customization requirements.

Aili Industry - From core components to complete clean workbench machines, it provides products and technical support for two-person collaborative assembly and inspection stations.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.