| Status: | |
|---|---|
| Quantity: | |
The desktop horizontal flow clean workbench arranges the terminal filter at the rear of the work area, and the filtered air passes forward through the operating area. Aili Industrial configures the work area around the desktop installation conditions, single-person operation range and placement of small workpieces, so that the equipment can form a local clean air supply within the limited desktop space.
Operation form |
Airflow direction |
Installation method |
Custom support |
|---|---|---|---|
Single person operation |
rear forward |
desktop placement |
Size, structure and function customization |
The equipment can be placed directly on the existing work surface without occupying independent floor space. Clean air flows forward from the rear filter outlet, passes through the operating area, and leaves from the front.
Desktop installation requires checking the table size, load-bearing capacity and rear air intake space. The equipment should be placed away from walls or other obstructions to ensure smooth air intake from the rear.
Configure the table height and work space according to the sitting or standing posture of the person, the size of the workpiece and the number of tools.
Frequently used tools should be placed in an area that is easily accessible and does not block key operating positions to reduce hand movement across the workpiece. The installation position of fixtures and instruments should also be determined in conjunction with the direction of air flow.
The weight of the equipment and the weight of the workpiece need to be carried by the tabletop. Before placing, check the desktop material, support method and local concentrated load capacity, and add pads or independent supports if necessary.
The side enclosures and operating openings together form a working area. The specific materials and structural dimensions can be confirmed according to the project. When it is necessary to install tooling or supporting equipment, the fixed hole positions, threading positions and accessory interfaces can be communicated.
Match the fan, motor and air duct according to the rear air supply area, filter resistance and target wind speed, taking into account the effective working area and operation adjustment requirements.
Filter selection needs to jointly clarify efficiency, size, installation sealing and replacement methods. Related configurations can be found HEPA and ULPA filters , select supporting products based on particle control requirements and system resistance.
Fan start and stop, wind speed adjustment, lighting and status display can be configured as needed.
For electronic components that are sensitive to static electricity, grounding, anti-static surfaces, and static elimination configurations can be evaluated and matched with personnel protection and site conditions. For workstations that run for a long time, the actual power of the DC or EC drive solution can be further checked.
After the air is initially filtered, it is sent into the filtration system by the fan, and then passes through the rear end high-efficiency filter, and is sent forward from the rear of the work area, and leaves the work area after passing through the operating area that needs to be protected.
Air enters → primary filter → fan supply → rear high-efficiency filter → passes through the work area horizontally → discharged from the front
After the horizontal airflow passes through the workpiece, it may carry particles generated by the operation. The front and rear positions of items should be properly arranged to avoid placing particle-sensitive workpieces downstream of particle-generating operations.
project |
Configuration instructions |
|---|---|
Product form |
Desktop horizontal flow clean workbench |
Airflow direction |
Supply air from the rear of the work area to the front |
Installation method |
desktop placement |
operating position |
One-person operation on the front side |
Work area size |
Confirm based on workpiece, tool and personnel operating scope |
effective working depth |
Determine based on workpiece position and air supply coverage |
clean target |
It can be configured according to the ISO level 5 work area target, and accepted according to the agreed particle size and testing status. |
Filtration system |
The primary effect is matched with the rear end high-efficiency filter |
Working wind speed |
Configure according to process requirements, and the speed adjustment range is confirmed according to the selected plan |
Countertop and cabinet |
Material, load-bearing and surface treatment are confirmed according to the project |
desktop hosting |
The total weight of equipment and workpieces, local loads and support methods shall be checked on site |
fan drive |
Configure according to air volume, resistance and speed adjustment requirements |
Control function |
Start/stop, speed adjustment, lighting and status display configured on demand |
Process interface |
Sockets, wiring holes and tooling fixing positions can be configured as needed |
Power and power |
Confirm by selected model and electrical requirements |
Test items |
Wind speed, particle concentration, filter leak detection and electrical inspection are carried out as agreed. |
Filter efficiency and work area cleanliness are different indicators, and equipment performance needs to be confirmed through complete machine testing. The difference between cleanliness level and filtration efficiency can be found in What is the difference between cleanliness level and filtration efficiency?。
Small parts assembly |
Precision parts inspection |
Optical component handling |
Instrument component assembly |
|---|---|---|---|
Desktop workstation operation |
Independent R&D workstation |
Clean parts handling |
Clean handling of non-hazardous materials |
Clean benches are mainly used for product protection and do not provide the personnel and environmental protection that biological safety cabinets have. The horizontal airflow is discharged in the direction of the operator. When infectious materials, toxic volatiles or other hazardous substances are involved, the appropriate equipment should be selected based on the risk.
The weight of the equipment and the weight of the workpiece need to be carried by the tabletop. Before placing, check the desktop material, support method and local concentrated load capacity, and add pads or independent supports if necessary. The rear air inlet space should also be kept clear.
Larger tools, instruments or workpieces may affect downstream airflow when placed in front of the filter. Front-to-back overlap should be reduced according to operational needs to maintain a direct clean air supply path for key operating locations.
When the desktop space is limited, after deepening the work area, it is necessary to combine the filter air outlet surface, side structure, wind speed and actual workpiece position to confirm the air flow and cleanliness performance of the operating area.
Particles can be generated from tool friction, packaging unpacking and workpiece handling. Steps should be arranged in conjunction with the direction of air flow to reduce the impact of these operations on sensitive downstream workpieces. Insufficient maintenance channels will increase subsequent expenditures. This is reflected in what later expenses will be increased due to insufficient maintenance channels . There is a more detailed analysis of
Clean the countertop, side enclosures and operating area according to process requirements to avoid residues affecting subsequent operations.
Maintain the primary filter according to the usage environment, and determine the maintenance needs of the terminal filter based on pressure difference, operating wind speed, cleanliness testing and filter status. After replacement, the installation seal and related performance should be rechecked.
Aili Industrial has a manufacturing base of approximately 30,000 square meters, covering R&D and manufacturing links such as motors, fans, control systems, sheet metal, air filters and complete machine assembly.
For desktop horizontal flow workbench projects, the filter area, fan working point, desktop load capacity, structural dimensions and control functions can be jointly checked to support product selection, non-standard design and batch project matching.
manufacturing link |
Project support |
|---|---|
Motors and fans |
Match desktop horizontal air supply, filter resistance and speed adjustment requirements |
air filter |
Check efficiency, effective dimensions and installation sealing |
control system |
Configure start/stop, speed adjustment, lighting and operation display |
Sheet Metal and Structure |
Implement workspace, desktop mounting structures and process interfaces |
Complete machine assembly and testing |
Organize production and inspection according to confirmed drawings and technical requirements |
Desktop size, load-bearing capacity and rear air intake space need to be checked. The weight of the equipment and workpiece should be safely carried by the tabletop, with supports or pads added if necessary.
The selection should be combined with the workpiece structure, air flow shielding and operating direction. For horizontal flow, attention should be paid to the front-to-back arrangement of the workpiece and downstream effects; for vertical flow, attention should be paid to top obstruction and airflow around the workpiece.
Grounding, anti-static flooring, and static elimination configurations can be evaluated based on component sensitivity, and inspection requirements can be clarified by project.
Designs can be based on workpieces, tools, personnel reach and desk space, while matching filter sizes, fan configurations and maintenance structures.
It should be combined with pressure difference, wind speed, cleanliness detection and filter status judgment. Recheck sealing and related performance after replacement.
Clarifying the workpiece size, placement direction, desktop conditions and cleanliness goals will help determine the work area and air supply configuration suitable for actual use conditions.
Contact us now to obtain the product information and technical parameters of the desktop horizontal flow clean workbench.
→ Consult desktop installation and workspace dimensions → Submit artifacts and tool layout
→ Learn about filtering and speed regulation configuration → Communicate about non-standard and equipment matching
pass Aili Industrial Technology Consulting , communicates product selection and customization needs.
Aili Industry - From core components to complete clean workbench machines, it provides products and technical support for small assembly, precision inspection and desktop workstations.