| Status: | |
|---|---|
| Quantity: | |
The floor-standing clean workbench is equipped with an independent support structure and can be placed directly on the ground to provide a partial clean work area for assembly, inspection and material sorting. Aili Industrial configures the table height, support form, filtration system and control functions based on the number of operators, workpiece size, air flow direction and on-site installation conditions to match the work area with the operating process.
Operation form |
Airflow direction |
Support method |
Custom support |
|---|---|---|---|
Single or multi-person station |
Horizontal or vertical flow optional |
Independent floor support |
Size, structure and function customization |
The equipment adopts an independent support structure and does not rely on the existing desktop for support. During installation, you need to check the flatness of the ground, the leveling range of the support feet and the total weight of the equipment, and confirm the ground load-bearing capacity if necessary.
The floor-standing structure makes it easy to adjust the height of the work area according to the height of the operator, and it is also convenient to reserve maintenance access around the equipment. Clean workbench classification and structural form can be viewed Clean Workbench Learn about different models.
The floor-standing workbench can select the airflow direction according to the workpiece shape and operation method. The horizontal flow passes through the work area from the rear to the front, which is suitable for workpieces with a relatively open windward surface; the vertical flow supplies air downward from the top, which is suitable for table operations and situations where the height of the workpiece is low.
The selection of the airflow direction needs to be confirmed based on the workpiece shielding, operating actions and background conditions, and cannot be determined solely by the size of the table. The structural differences between the two airflows can be referred to How to choose between horizontal flow and vertical flow clean workbench? learn.
The table height can be configured according to the standing or sitting posture of the person, reducing fatigue during long-term operation. The load capacity of the tabletop needs to be checked based on the weight of the workpiece, fixture and instrument. For heavier concentrated loads, the support position and local reinforcement method should be confirmed.
The countertop material, surface treatment and process interface can be configured according to the cleaning method and usage requirements. When it is necessary to install tooling or supporting equipment, the fixed hole positions, threading positions and accessory interfaces can be communicated.
Match the fan, motor and air duct according to the air supply area, filter resistance and target wind speed, taking into account the effective working area and operation adjustment requirements.
Filter selection needs to jointly clarify efficiency, size, installation sealing and replacement methods. Related configurations can be found HEPA and ULPA filters , select supporting products based on particle control requirements and system resistance.
Front operating channels, rear air inlet spaces and filter replacement paths need to be reserved around floor-standing equipment. When the equipment is placed against a wall or side by side with other equipment, make sure that the maintenance door and access hatch can be opened normally.
Insufficient maintenance access will increase the cost of disassembly, assembly and downtime in the future. what later expenses will be increased due to insufficient maintenance channels . There is a more detailed analysis of
After the air is initially filtered, it is sent to the filtration system by the fan, and then enters the work area through the final high-efficiency filter. The horizontal flow model supplies air from the rear to the front, while the vertical flow model supplies air downward from the top. The airflow passes through the operating area and is discharged along the designed path.
Air enters→primary filter→fan supply→end high-efficiency filter→work area air supply→air discharge
Personnel movements, tools, and larger workpieces may change local airflow. The performance of the work area should be checked based on the actual placement and working status.
project |
Configuration instructions |
|---|---|
Product form |
Floor-standing clean workbench |
Support method |
Independent floor support, adjustable |
Airflow direction |
Horizontal flow or vertical flow, confirmed according to process |
operating position |
Single or multiple workers, configured according to the plan |
Work area size |
Confirm based on workpiece, tool and personnel operating scope |
effective working depth |
Determine based on workpiece position and air supply coverage |
clean target |
It can be configured according to the ISO level 5 work area target, and accepted according to the agreed particle size and testing status. |
Filtration system |
Primary effect and terminal high efficiency filter matching |
Working wind speed |
Configure according to process requirements, and the speed adjustment range is confirmed according to the selected plan |
Countertop and cabinet |
Material, load-bearing and surface treatment are confirmed according to the project |
Countertop height |
Confirm according to the person’s standing or sitting posture and operating habits |
fan drive |
Configure according to air volume, resistance and speed adjustment requirements |
Control function |
Start/stop, speed adjustment, lighting and status display configured on demand |
Process interface |
Sockets, wiring holes and tooling fixing positions can be configured as needed |
Power and power |
Confirm by selected model and electrical requirements |
Test items |
Wind speed, particle concentration, filter leak detection and electrical inspection are carried out as agreed. |
Filter efficiency and work area cleanliness are different indicators, and equipment performance needs to be confirmed through complete machine testing. The difference between cleanliness level and filtration efficiency can be found in What is the difference between cleanliness level and filtration efficiency?。
Electronic component assembly |
Precision parts inspection |
Optical component handling |
Instrument component assembly |
|---|---|---|---|
Independent assembly station |
Floor testing station |
Clean parts handling |
Clean handling of non-hazardous materials |
Clean benches are mainly used for product protection and do not provide the personnel and environmental protection that biological safety cabinets have. When infectious materials, toxic volatiles, or other hazardous materials are involved, equipment should be selected based on the risk.
Floor-standing equipment needs to check the flatness of the ground, load-bearing capacity and installation space. The equipment should remain stable after leveling to avoid operating vibrations that affect precision operations.
The height of the table should be determined based on the standing or sitting posture of the person, the size of the workpiece and the operating movements. Too high or too low may increase fatigue and affect operational stability.
Space needs to be reserved for air inlet, filter replacement and fan maintenance at the rear of the equipment. When installing against a wall, you should confirm whether there is still enough air inlet channel at the rear. Insufficient maintenance channels will increase subsequent expenditures. This is reflected in what later expenses will be increased due to insufficient maintenance channels . There is a more detailed analysis of
Agree on the detection range in the working area, near the filter joints and at the actual operating position. When the partition is running, the expected opening combination should be checked, and the detection results when all areas are turned on cannot be used instead of other operating states.
Clean the countertop, side enclosures and operating area according to process requirements to avoid residues affecting subsequent operations.
Maintain the primary filter according to the usage environment, and determine the maintenance needs of the terminal filter based on pressure difference, operating wind speed, cleanliness testing and filter status. After replacement, the installation seal and related performance should be rechecked. To judge the initial resistance and final resistance, please refer to What are the initial resistance and final resistance used to judge? , sealing inspection can refer to What should be checked when cleaning equipment is accepted?。
Aili Industrial has a manufacturing base of approximately 30,000 square meters, covering R&D and manufacturing links such as motors, fans, control systems, sheet metal, air filters, and complete machine assembly.
For floor-standing workbench projects, the support structure, table load-bearing capacity, filter area, fan working point and control functions can be checked together to support product selection, non-standard design and batch project matching.
manufacturing link |
Project support |
|---|---|
Motors and fans |
Matching floor-standing workstation air supply, filter resistance and speed adjustment requirements |
air filter |
Check efficiency, effective dimensions and installation sealing |
control system |
Configure start/stop, speed adjustment, lighting and operation display |
Sheet Metal and Structure |
Implement floor support, table top and process interface |
Complete machine assembly and testing |
Organize production and inspection according to confirmed drawings and technical requirements |
The floor-standing type adopts an independent support structure and does not rely on the existing desktop, so it is suitable for independent workstations and heavier workpieces; the desktop type is placed directly on the existing tabletop and is suitable for small workstations with limited desktop space.
The selection should be combined with the workpiece structure, air flow shielding and operating direction. For horizontal flow, attention should be paid to the front-to-back arrangement of the workpiece and downstream effects; for vertical flow, attention should be paid to top obstruction and airflow around the workpiece.
It can be confirmed based on the standing or sitting posture of the person, the size of the workpiece and operating habits. The specific adjustment range and method are confirmed by the technical plan.
It is necessary to confirm the rear air inlet space and filter replacement path. When installing against a wall, the necessary maintenance distance should be maintained.
It should be combined with pressure difference, wind speed, cleanliness detection and filter status judgment. Recheck sealing and related performance after replacement.
Clarifying the workpiece size, number of operators, air flow direction, installation space and maintenance conditions will help determine the floor-standing workstation configuration suitable for the actual process.
Contact us immediately to obtain product information and technical parameters of floor-standing clean workbench.
→ Consult floor-standing installation and work area dimensions → Submit artifacts and operation layout
→ Learn about filtering and speed regulation configuration → Communicate about non-standard and equipment matching
pass Aili Industrial Technology Consulting , communicates product selection and customization needs.
Aili Industry - From core components to complete clean workbench machines, it provides products and technical support for independent assembly, precision inspection and floor-standing workstations.