product

Product Category

loading

Triple-double air shower room

Aili industrial three-person double-blowing air shower adopts an extended cavity and double-sided nozzles, which can be matched with three-person group entry, station position and complete blowing cycle. It can be configured according to the number of people on shift, entrance movement line, induction conditions, materials and installation space. Supports size, material, door body, filtration system and group control configuration, and can be customized according to personnel traffic volume and on-site conditions.

 
state:
quantity:

Aili Industrial Three-person Double-Blow Air Shower

Equipped with extended double-side blowing and shower equipment for three-person group traffic

The three-person double-blowing air shower adopts an elongated cavity that can accommodate three people for showering at the same time or in groups. Aili Industrial configures the cavity size, nozzle layout, door structure and filtration system based on the number of people changing shifts, entrance movement lines, grouping methods and induction control requirements, so that the air shower room maintains traffic efficiency and blowing coverage in multi-person shift scenarios.

Operation form

Blowing method

Applicable places

Custom support

Three people traveling in the same cycle or in groups

Double side nozzle shower

Clean room personnel entrance

Size, material and function customization

Features

Extended cavity and three-person position

The length of the inner cavity of a three-person air shower needs to accommodate three people standing. There are usually two types of positioning methods: front-to-back arrangement and grouping arrangement. Different positioning methods affect the length, width and blowing coverage of the cavity.

If three people stand front to back, the length of the cavity needs to be increased accordingly, and the blowing nozzle should cover the front, middle and rear positions. If three people stand side by side, the width of the cavity needs to be enough for three people to turn around at the same time. Air shower room classification and structural form can be viewed Air showers understand different models.

Blowing shower coverage at front, middle and rear positions

When used by three people, the nozzle layout needs to cover the front, middle and rear positions. People in the front row may block part of the airflow for people in the back row. When selecting a model, you should confirm whether the number and angle of the nozzles can cover three positions at the same time.

If group showering is used, three people can be divided into two groups and showered one after another to reduce mutual obstruction. The specific grouping logic should match the traffic flow and shower time. For the conversion of face wind speed and air volume, please refer to How to convert face wind speed and air volume? learn.

Filter circulation and return air structure

After the air passes through the primary filter and high-efficiency filter, it is sent to the nozzle by the fan, blows the surface of the personnel, and then returns to the front end of the filtration system through the return air outlet to form a cycle.

The air volume and return air area of ​​the three-person air shower room increase accordingly, and it should be checked whether the fan working point meets the requirements. The return air outlet should be kept clear to prevent obstruction by clothing or objects from affecting circulation. Return air filtration needs to be matched with the nozzle layout, air duct and fan working point.

Sensing layout and group access logic

Three-person air showers are usually equipped with induction control, which automatically starts the shower after personnel enter. The sensing range needs to cover the three-person standing area, and the activation logic should match the group traffic method.

If group showering is used, the sensing system can identify the number of people entering or grouping areas and start showering according to the corresponding logic. The front and rear doors are interlocked to prevent the doors on both sides from being opened at the same time and causing an airflow short circuit. For control logic, please refer to Double double blow air shower room is suitable for multi-passage configuration.

Box material and surface treatment

The air shower box can be made of stainless steel or steel plate with plastic spray material, which shall be confirmed according to the use environment, cleaning requirements and appearance requirements. Stainless steel is corrosion-resistant and easy to clean, making it suitable for places with high surface cleaning requirements.

The inner wall should be smooth, not prone to dust accumulation, and easy to wipe daily. The three-person air shower has a long cavity, and the corner treatment and lighting arrangement should be convenient for inspection and cleaning.

Working principle

After people enter the air shower room, the induction device triggers the fan to start. After primary filtration, the air is sent to the high-efficiency filter by the fan, and then blown to the surface of the personnel through the nozzles on both sides. The air carrying particles returns to the front end of the filtration system through the return air outlet, forming a cycle.

Personnel enters → Induction start → Primary filter → Fan air supply → High efficiency filter → Double-sided nozzle blowing → Return air circulation → End of blowing → Unlock the exit door

When three people are showering at the same time, their positions and clothing may block local airflow from each other. The blowing effect should be confirmed based on the actual traffic flow and standing position, and group blowing should be used if necessary.

Technical parameters and configuration

project

Configuration instructions

Product form

Triple-double air shower room

means of transportation

Three people can pass in the same cycle or in groups, and the front and rear doors are interlocked

Blowing method

Double side nozzle shower

Overall dimensions

Confirm according to installation space, traffic direction and maintenance conditions

Inner cavity size

Determined based on the three-person stance and turning space

Number of nozzles

Configure according to cavity size and front, middle and rear coverage requirements

Filtration system

Primary effect and high efficiency filter matching

Shower wind speed

Configure according to process requirements, and the acceptance scope is determined by the technical agreement

Shower time

Set according to management requirements, and the adjustable range is confirmed according to the control plan

Access control interlock

Front and rear doors interlock to prevent simultaneous opening

Cabinet material

Stainless steel or steel plate spraying, confirmed by project

fan drive

Configure according to air volume, resistance and operation requirements

Control function

Induction start, group shower, shower timing, status display and linkage interface configured on demand

illumination

Configured for internal operations and inspection needs

Power and power

Confirm by selected model and electrical requirements

Test items

Wind speed, filter leak detection and electrical inspection are carried out as agreed.

The performance of the air shower needs to be confirmed through complete machine testing and cannot be judged solely based on filter efficiency. For the difference between filter efficiency and work area cleanliness, please refer to What is the difference between cleanliness level and filtration efficiency?。

Application scenarios

Electronics factory shift change entrance

Entrance to the medical clean area team

Multi-person access in the food workshop

Multi-person group blowing and showering stations

Three people traveling in the same cycle

Team purification process

Passage during shift rush hour

Clean handling of non-hazardous materials

The air shower is mainly used for surface blowing of personnel and clean area entrance management. It does not replace the dressing process, material purification and the air purification system of the clean room itself. When infectious or hazardous materials are involved, equipment should be selected based on the risk.

Key points for air shower selection and installation

Confirm the number of people changing shifts and the way of passage

The three-person air shower is suitable for shift peak times or team traffic scenarios. When selecting a model, you should confirm the number of people passing through per hour, whether three people can enter at the same time, whether they can be showered in groups, and whether the standing position is front to back or side by side.

Check the three-person positioning and shower coverage

Three people standing in front of each other or side by side will affect the shower coverage. It should be confirmed whether the nozzle layout can cover the front, middle and rear positions to prevent people in the front row from blocking the shower airflow of those in the back row.

Confirm sensor layout and grouping logic

The sensing range should cover the three-person standing area, and the activation logic should match the group traffic method. If group blowing is used, the control plan and blowing cycle should be confirmed.

Reserve space for installation and maintenance

The three-person air shower has a longer appearance. Before installation, the door opening size, floor flatness and surrounding passages should be checked. The return air vent and filter require regular maintenance, and maintenance channels should be reserved around them. Insufficient maintenance channels will increase subsequent expenditures. This is reflected in what later expenses will be increased due to insufficient maintenance channels . There is a more detailed analysis of

Routine maintenance

Clean the inner wall, nozzles and return air outlets of the air shower in accordance with management requirements to avoid dust accumulation that affects the shower effect. Pay attention to protecting the nozzle angle and filter system seal when cleaning.

Maintain the primary filter according to the frequency of use and environment, and determine the maintenance needs of the high-efficiency filter based on pressure difference, wind speed and filter status. After replacement, the installation seal and related performance should be rechecked. To judge the initial resistance and final resistance, please refer to What are the initial resistance and final resistance used to judge? , sealing inspection can refer to What should be checked when cleaning equipment is accepted?。

Regularly check access control interlocks, induction devices and shower timing functions to ensure that the three-person access process is normal.

The synergistic advantages of the entire industrial chain of Aili Industry

Aili Industrial has a manufacturing base of approximately 30,000 square meters, covering R&D and manufacturing links such as motors, fans, control systems, sheet metal, air filters, and complete machine assembly.

For the three-person double-blowing air shower project, the cavity size, nozzle layout, filter configuration, fan working point and control function can be checked together to support standard selection, non-standard design and batch project matching.

manufacturing link

Project support

Motors and fans

Matching the three-person shower air volume, filter resistance and operation requirements

air filter

Check efficiency, size and installation seals

control system

Configure induction start, group shower, access control interlock and linkage interface

Sheet Metal and Structure

Achieve lengthened cavity, nozzle layout and installation structure

Complete machine assembly and testing

Organize production and inspection according to confirmed drawings and technical requirements

FAQ

What is the difference between a three-person double-blowing air shower and a double air shower?

The three-person air shower has a longer cavity and can accommodate three people to shower at the same time or in groups. It is suitable for places with a large number of people changing shifts. The double air shower room is suitable for the scenario where two people pass through at the same time.

Will three people cover each other if they shower at the same time?

The three-person standing position and clothing may block local airflow, especially when standing forward or backward. When selecting the model, confirm the nozzle layout and positioning method, and use group blowing if necessary.

Can I shower in groups?

The group purge logic can be configured according to the general flow, and the specific plan can be confirmed in the control system. Grouped showers can reduce mutual occlusion, but they need to be matched with traffic efficiency.

Can the shower time be adjusted?

The blowing time is usually adjustable, and the specific range is confirmed according to the control plan. When used by three people, the setting value can be adjusted according to traffic efficiency.

How often should the filter be replaced?

It should be judged based on the pressure difference, wind speed and filter status. Recheck sealing and related performance after replacement.

Three-person double-blowing air shower room selection and technical consultation

Clarifying the number of shifts, traffic methods, installation space, shower requirements and material requirements will help determine the configuration of a three-person air shower suitable for the clean room entrance.

Contact us immediately to obtain the product information and technical parameters of the three-person double-blowing air shower.

→ Consult the size and position of the three-person air shower → Submit access procedures and grouping requirements
→ Learn about filtering and control configuration → Communicate on non-standard and batch projects

pass Aili Industrial Technology Consulting , communicates product selection and customization needs.

Aili Industry - From core components to complete air shower machines, it provides products and technical support for clean room personnel entrance, changing process and multi-person traffic management.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.