product

Product Category

loading

Double double blow air shower room

Aili Industrial Double-Blow Air Shower adopts an extended cavity and double-sided nozzles. It can be used by two people at the same time to confirm the station, entry sequence and sensor control. It is suitable for the entrance of clean areas. It supports size, material, door body, filtration system and traffic logic configuration, and can be customized according to the traffic volume and on-site conditions.

 
state:
quantity:

Aili Industrial Double-Blow Air Shower

Equipped with double-side blowing and shower equipment for two people to pass in the same cycle

The double-person double-blowing air shower adopts an extended cavity, which can accommodate two people to shower at the same time. Aili Industrial configures the cavity size, nozzle layout, door structure and filtration system according to the personnel traffic volume, entry sequence, station mode and induction control requirements, so that the air shower can maintain traffic efficiency during shift peaks or double traffic scenarios.

Operation form

Blowing method

Applicable places

Custom support

Passage for two persons on the same cycle

Double side nozzle shower

Clean room personnel entrance

Size, material and function customization

Features

Extended cavity and double position

The length and width of the inner cavity of a double air shower need to accommodate two people standing side by side or front to back. The station position affects blowing and shower coverage and traffic efficiency, and should be confirmed in conjunction with the personnel traffic process during model selection.

If two people stand side by side, the width of the cavity should ensure that each person has enough room to turn around; if they stand front to back, the length of the cavity needs to be increased accordingly. Air shower room classification and structural form can be viewed Air showers understand different models.

Double side nozzles with blow-down coverage

The air shower room is equipped with nozzles on both sides to spray the surface of people's clothing from different angles. When using it with two people, you should confirm whether the nozzle coverage can cover the standing positions of two people at the same time to avoid one person blocking the shower airflow of the other person.

The number, angle and air outlet speed of the nozzles can be configured according to the cavity size and blowing requirements. After entering, personnel should turn their bodies in the shower area so that all surfaces can be covered by the airflow. For specific air volume calculations, please refer to How to convert face wind speed and air volume?。

Filter circulation and return air structure

After the air passes through the primary filter and high-efficiency filter, it is sent to the nozzle by the fan, blows the surface of the personnel, and then returns to the front end of the filtration system through the return air outlet to form a cycle.

Return air filtration needs to be matched with the nozzle layout, air duct and fan working point. The air volume and return air area of ​​the double air shower room increase accordingly, and you should check whether the fan working point meets the requirements. The return air outlet should be kept clear to prevent obstruction by clothing or objects from affecting circulation.

Sensor control and two-passenger traffic logic

Double air showers are usually equipped with induction control, which automatically starts the shower after people enter. The sensing range and start-up logic need to match the two-person positioning to prevent one person from starting the timing before the other person is in position.

The front and rear doors are interlocked to prevent the doors on both sides from being opened at the same time and causing an airflow short circuit. The blowing time can be set according to management requirements, and the blowing cycle may need to be adjusted when used by two people. For specific control logic, please refer to Learn about the basic configuration of a single-person double-blowing air shower .

Box material and surface treatment

The air shower box can be made of stainless steel or steel plate with plastic spray material, which shall be confirmed according to the use environment, cleaning requirements and appearance requirements. Stainless steel is corrosion-resistant and easy to clean, making it suitable for places with high surface cleaning requirements.

The inner wall should be smooth, not prone to dust accumulation, and easy to wipe daily. The double air shower has a long cavity, and the corner treatment and lighting arrangement should be convenient for inspection and cleaning.

Working principle

After people enter the air shower room, the induction device triggers the fan to start. After primary filtration, the air is sent to the high-efficiency filter by the fan, and then blown to the surface of the personnel through the nozzles on both sides. The air carrying particles returns to the front end of the filtration system through the return air outlet, forming a cycle.

Personnel enters → Induction start → Primary filter → Fan air supply → High efficiency filter → Double-sided nozzle blowing → Return air circulation → End of blowing → Unlock the exit door

When two people are showering at the same time, their positions and clothing may block local airflow from each other. The shower effect should be confirmed based on the actual traffic flow and standing position.

Technical parameters and configuration

project

Configuration instructions

Product form

Double double blow air shower room

means of transportation

Two people pass in the same cycle, and the front and rear doors are interlocked

Blowing method

Double side nozzle shower

Overall dimensions

Confirm according to installation space, traffic direction and maintenance conditions

Inner cavity size

Determined based on the two-person stance and turning space

Number of nozzles

Configure according to cavity size and blowout coverage requirements

Filtration system

Primary effect and high efficiency filter matching

Shower wind speed

Configure according to process requirements, and the acceptance scope is determined by the technical agreement

Shower time

Set according to management requirements, and the adjustable range is confirmed according to the control plan

Access control interlock

Front and rear doors interlock to prevent simultaneous opening

Cabinet material

Stainless steel or steel plate spraying, confirmed by project

fan drive

Configure according to air volume, resistance and operation requirements

Control function

Induction start, shower timing, status display and linkage interface configured on demand

illumination

Configured for internal operations and inspection needs

Power and power

Confirm by selected model and electrical requirements

Test items

Wind speed, filter leak detection and electrical inspection are carried out as agreed.

The performance of the air shower needs to be confirmed through complete machine testing and cannot be judged solely based on filter efficiency. For the difference between filter efficiency and work area cleanliness, please refer to What is the difference between cleanliness level and filtration efficiency?。

Application scenarios

Electronics factory shift change entrance

Entrance to pharmaceutical clean area

Food clean workshop entrance

Entrance to multi-passage clean area

Passage for two persons on the same cycle

Personnel decontamination process

Passage during shift rush hour

Clean handling of non-hazardous materials

The air shower is mainly used for surface blowing of personnel and clean area entrance management. It does not replace the dressing process, material purification and the air purification system of the clean room itself. When infectious or hazardous materials are involved, equipment should be selected based on the risk.

Key points for air shower selection and installation

Confirm the number of people passing through and the way they pass

The double air shower room is suitable for places where there are shift peaks or where two people pass through at the same time. When selecting a model, you should confirm the number of people passing through per hour, whether two people enter at the same time, and whether they stand front to back or side by side.

Check double positioning and shower coverage

Two people standing side by side or in front of each other will affect the shower coverage. It should be confirmed that the nozzle layout can cover the standing positions of two people at the same time to prevent one person from blocking the shower airflow of another person.

Confirm sensing range and pass logic

The sensing range should cover the two-person standing area, and the activation logic should match the traffic flow. Access control interlocking and shower time need to be adjusted according to the double passage efficiency.

Reserve space for installation and maintenance

The air shower has a large external dimension, so the door opening size, floor flatness and surrounding passages should be checked before installation. The return air vent and filter require regular maintenance, and maintenance channels should be reserved around them. Insufficient maintenance channels will increase subsequent expenditures. This is reflected in what later expenses will be increased due to insufficient maintenance channels . There is a more detailed analysis of

Routine maintenance

Clean the inner wall, nozzles and return air outlets of the air shower in accordance with management requirements to avoid dust accumulation that affects the shower effect. Pay attention to protecting the nozzle angle and filter system seal when cleaning.

Maintain the primary filter according to the frequency of use and environment, and determine the maintenance needs of the high-efficiency filter based on pressure difference, wind speed and filter status. After replacement, the installation seal and related performance should be rechecked. To judge the initial resistance and final resistance, please refer to What are the initial resistance and final resistance used to judge? , sealing inspection can refer to What should be checked when cleaning equipment is accepted?。

Regularly check the access control interlock, sensor device and shower timing function to ensure that the two-person passage process is normal.

The synergistic advantages of the entire industrial chain of Aili Industry

Aili Industrial has a manufacturing base of 30,000 square meters, covering R&D and manufacturing links such as motors, fans, control systems, sheet metal, air filters and complete machine assembly.

For a double-person double-blowing air shower project, the cavity size, nozzle layout, filter configuration, fan working point and control function can be checked together to support standard selection, non-standard design and batch project matching.

manufacturing link

Project support

Motors and fans

Matching double shower air volume, filter resistance and operation requirements

air filter

Check efficiency, size and installation seals

control system

Configure induction start, shower timing, access control interlock and linkage interface

Sheet Metal and Structure

Achieve lengthened cavity, nozzle layout and installation structure

Complete machine assembly and testing

Organize production and inspection according to confirmed drawings and technical requirements

FAQ

What is the difference between a double double blow air shower and a single air shower?

The double air shower has an elongated cavity that can accommodate two people showering at the same time, making it suitable for shift rush hours or double-passage scenarios. Single-person air showers are suitable for places with small traffic volume.

Will two people cover each other if they shower at the same time?

The two people's standing positions and clothing may block local airflow. The nozzle layout and positioning method should be confirmed when selecting the model, and the blowing effect should be verified according to the agreed conditions after installation.

Can the shower time be adjusted?

The blowing time is usually adjustable, and the specific range is confirmed according to the control plan. When used by two people, the setting value can be adjusted according to traffic efficiency.

Can the access control interlock be turned off?

The access control interlock is a configuration that prevents the doors on both sides from being opened at the same time. It should be used according to management requirements and is not recommended to be closed. The specific logic is confirmed in the control scheme.

How often should the filter be replaced?

It should be judged based on the pressure difference, wind speed and filter status. Recheck sealing and related performance after replacement.

Double double blow air shower room selection and technical consultation

Clarifying the amount of personnel traffic, traffic methods, installation space, shower requirements and material requirements will help determine the double air shower configuration suitable for the clean room entrance.

Contact us now to obtain the product information and technical parameters of the double-person double-blowing air shower.

→ Consult the size and position of the double air shower → Submit access procedures and access requirements
→ Learn about filtering and control configuration → Communicate on non-standard and batch projects

pass Aili Industrial Technology Consulting , communicates product selection and customization needs.

Aili Industry - From core components to complete air shower machines, it provides products and technical support for clean room personnel entrance, changing process and traffic management.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.