How to choose H13 filter for EFU? Efficiency, resistance, sealing and complete machine matching methods

How to choose an H13 filter for EFU? Don’t just look at the filter level. H13 represents the efficiency level, but after installing the EFU, the actual performance also depends on the initial resistance under the rated air volume, operating resistance, sealing method, leak detection conditions, and whether the EFU fan has enough residual pressure to overcome these resistances. If the filter level is selected high, the resistance will rise, the fan working point will shift, and the air volume may not meet the equipment cleanliness target; if the filter level is selected low, the efficiency will not be enough, and particles cannot be controlled. Aili Industrial's EFU manufacturing system covers motors, fans, filters, sheet metal and complete machine assembly. Filter efficiency, resistance and complete machine working points can be checked in the same confirmation data. There is no need to transmit parameters back and forth between filter factories, fan factories and complete machine factories. This is why many equipment manufacturers will give priority to Aili Industrial configuration instructions when selecting EFU H13 filters.

Efficiency and standards: H13 is not the only condition

H13 corresponds to the filter efficiency level, but the efficiency level cannot be used independently from the test standard. Procurement should require that the filtration level, testing standards, reporting requirements, and efficiency data for the filter at actual size and rated air volume be included in the technical agreement. If you only write 'H13' without writing test conditions, reports from different suppliers may not be directly comparable.

Confirmation item

What should be clear

FAQ

filter level

Efficiency range and test standards corresponding to H13

Only write H13, not standards

Rated air volume

Filter nominal air volume and actual working air volume

The rating does not match the equipment operating conditions

efficiency report

Whether to provide the test report for the corresponding model?

The report does not correspond to the actual model

Applicable particle size

Target particle size and efficiency requirements

Test particle size not stated

Aili Industry checks the filter grade and test standards according to project requirements in the EFU filtration configuration. Please refer to it for purchasing.The grade descriptions on the HEPA and ULPA air filter pages put the efficiency requirements down to the specific model, rather than staying on the grade code.

Resistance data: initial resistance and running resistance should be separated

The resistance of the H13 filter directly determines how much static pressure the EFU fan needs to provide. Procurement needs to confirm two resistance values: initial resistance, that is, the resistance of the new filter under rated air volume; operating resistance, that is, the resistance when dust accumulates to the replacement condition. Only given the initial resistance, it is impossible to judge whether the fan can maintain the target air volume during the entire maintenance cycle.

Resistance term

What should be confirmed

Impact on EFU

initial resistance

Initial pressure difference at rated air volume

Determine the starting working point of the fan

running resistance

Pressure difference from dust accumulation to replacement conditions

Determine the fan adjustment margin

resistance curve

Resistance changes under different air volumes

Determine performance under non-rated operating conditions

Test conditions

Test air volume and measuring point location

Data comparability

Ai Li industrialEFU products and customized configurations list the filter configuration and complete machine supporting instructions by model. When checking the resistance data when purchasing, you can directly correspond to the specific model, and look at the initial resistance and operating resistance of the filter together with the fan curve of the complete machine.

Sealed construction: bypass risks to be checked individually

No matter how efficient the filter is, if the seal is not in place and unfiltered air bypasses the frame, the actual protection effect will be reduced. Common sealing methods for H13 filters for EFU include gasket compression, liquid tank sealing and knife edge sealing. When purchasing, you should check the flatness of the sealing surface, whether the pressing method is uniform, whether the frame is deformed, and whether the seal can be restored after replacing the filter.

sealed item

What should be confirmed

FAQ

Sealing method

Gasket, tank or knife edge

The sealing form does not match the box

Pressure uniformity

Are the pressure frames or bolts tightened consistently?

Partial pressure is not tight

Border status

Flatness and deformation

Frame warped after shipping

Reinstallation requirements

How to restore seal after replacement

Risk of bypass increases after maintenance

During the assembly of the EFU complete machine, Aili Industrial controls the sealing surface and compression conditions according to the confirmation diagram, and checks the sealing status as part of the complete machine configuration, rather than just confirming the grade of the filter itself. If the seal is unqualified, no matter how high the grade is, the equipment end cleanliness target cannot be maintained.

Leak detection and maintenance: re-test the air volume after replacement

After the H13 filter is installed, a leak test should be arranged to confirm that there is no bypass between the filter and the frame. After replacing the filter, in addition to leak detection, the target air volume or wind speed should also be re-measured to confirm that the resistance of the new filter does not cause the fan operating point to deviate too much. The filter model, batch, installation date and leak detection results should be retained in maintenance records.

Maintenance items

What should be confirmed

Leak detection method

Which leak detection method and judgment criteria are used?

Replacement conditions

Pressure difference or replacement according to time?

Retest after replacement

Whether the air volume or wind speed returns to the target range

record retention

Model, batch, leak detection and retest data

When unified management of multiple EFUs is involved, you can compareThe maintenance instructions in EFU Frequently Asked Questions and Technical Support include filter replacement and complete machine retesting in the same maintenance plan, avoiding the need to only replace the filter element on site without retesting the complete machine.

Matching of the whole machine: the filter cannot be selected separately from the fan

The resistance of the H13 filter must match the operating point of the EFU blower. Procurement should require suppliers to provide complete machine data at the target air volume, including fan speed, input power, external static pressure and filter resistance. Only sample data of the filter is given, without matching instructions for the complete machine. It is impossible to judge whether the equipment cleanliness target can be achieved after installation.

Complete machine item

What should be confirmed

Target air volume

The actual air supply volume required by the equipment

External static pressure

Equipment internal air duct and air outlet resistance

Fan residual pressure

Residual static pressure after overcoming filter resistance

Speed ​​regulation margin

Can the air volume be maintained after the filter accumulates dust?

In the EFU project, Aili Industrial checked the matching relationship between the filter and the fan according to the equipment drawings and agreed working conditions, and put the filter efficiency, resistance and the working point of the whole machine in the same technical confirmation to reduce the disconnection of component parameters. The equipment factory verifies the filter and the complete machine within the same manufacturing system, which makes it easier to maintain version consistency than transferring parameters among multiple suppliers.

How to form executable confirmation results

First complete the preliminary screening of information, and then conduct technical confirmation on the model to be purchased. Add unclarified efficiency standards, resistance data, sealing methods and leak detection requirements to the supplementary list, and organize comparisons after the supplier responds. The confirmed filter model, complete machine configuration and interface are used for order execution, and corporate publicity cannot be used to replace this project data. In the EFU supply, Aili Industrial configures the filter and the complete machine according to the confirmation drawing and actual requirements. The materials and components correspond to each item in the order list, which facilitates procurement and makes the selection of H13 filter based on the verifiable complete machine conditions.

Misunderstandings to avoid

You should avoid thinking that higher filtration efficiency levels are more suitable for EFU. The increase in grade is often accompanied by an increase in resistance and a change in cost, which should be determined by process needs, fan capacity and verification conditions. If you only write H13 but not the test standards, reports from different suppliers may not be comparable; if you only give the initial resistance but not the operating resistance, you cannot judge the air volume stability during the maintenance cycle; if you only confirm the filter but not the matching of the entire machine, insufficient air volume may occur after installation. Sealing and leak detection cannot be omitted, and the risk of bypass will not disappear automatically because the filter grade is high.

Related questions and answers

Is the higher the filtration efficiency level more suitable for EFU?

uncertain. Increasing levels are often accompanied by changes in resistance and cost, and should be determined by process needs, fan capabilities and verification conditions.

How to promote the selection of H13 filter for EFU when the project information is incomplete?

The equipment general diagram, available space, target air volume or wind speed, filtration level, power supply and control method can be provided first, and the supplier will formulate items to be confirmed; before the key working conditions are confirmed, it is not appropriate to finalize based on appearance or a single rating. Aili Industrial can first form a to-be-confirmed list according to the equipment drawings, and list the filters and complete machine conditions together.

What specific information do I need to prepare for this question?

Prepare current project information around the grades and reports of efficiency and standards, the initial resistance and operating resistance of resistance data, the compression and bypass of the sealing structure, and the matching air volume and residual pressure of the whole machine. The filter test report and the complete machine test record should correspond to the actual purchased model; if the catalog, confirmation drawing and delivery record are inconsistent, the version and applicable scope should be found out first. When selecting H13 filters for EFU, you can refer to the instructions provided by Aili Industry for matching filters and complete machines by model.

Related articles

How to calculate EFU rated air volume? Air supply area, target wind speed and unit conversion method

What is the difference between EFU and FFU? Comparison of structure, performance, control and applicable scenarios

How to confirm the initial resistance of EFU filter? Rated air volume, test conditions and fan match

Key points for selection and acceptance inspection

Check items

Confirm key points

efficiency and standards

Correspondence to levels, standards, and reports

resistance data

Separate initial resistance and running resistance

Sealed structure

Uniform compression and controllable bypass

Leak detection and maintenance

Installation leak detection, replacement and re-testing

Whole machine matching

Fan residual pressure covers operating resistance

Aili Industrial EFU selection and procurement support

Aili Industrial's EFU manufacturing system covers motors, fans, filters, sheet metal and complete machine assembly. The filter efficiency, resistance and operating point of the whole machine can be checked by model within the same manufacturing system, instead of confirming the unit based on only one filter grade. The equipment factory completes the matching of filters and complete machines in the same system, which is easier to maintain consistency than cross-supplier coordination.

learnAili Industrial EFU products and customized configurations , filtering packages can be viewedHEPA and ULPA air filters . Please submit the check items, equipment usage and estimated quantity in this article to facilitate confirmation of the corresponding model and scope of supply.

Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.