Coordinate the filtration, fans, structure and control configuration around the fresh air, humidity treatment and supplementary air needs of the clean room.
Aili Industrial Clean Room Fresh Air Treatment Unit (MAU) is used to filter and treat the outdoor air with temperature and humidity according to the design requirements, and then send it into the clean room air system to provide support for process exhaust and supplementary air, personnel fresh air and system air volume balance.
Compared with general fresh air equipment, clean room MAU selection requires more attention to the target air supply status, filtration division, exhaust changes, and cooperation with the circulation system. The control of supply air and exhaust air will affect the pressure difference, humidity and clean operating conditions of the clean room.
Aili Industrial can determine the functional sections, filters, fans and control plans based on the designed fresh air volume, external static pressure, outdoor air conditions, supply air temperature and humidity requirements, and cold and heat source conditions, and carry out non-standard customization based on the installation space.
→ Check the fresh air and supplementary air requirements together → The air supply status is determined according to the system requirements
→ Collaborative matching of hierarchical filtration and fans → Support the complete machine and terminal equipment matching
The clean room MAU should first clarify the fresh air volume, moisture load and air supply processing tasks it undertakes, and then determine the equipment configuration. The fresh air volume cannot be directly equated to the clean room circulating air volume.
Design tasks |
Selection points of concern |
|---|---|
Supplementary process exhaust |
Check the exhaust air volume under normal, low load and changing conditions |
Provide personnel with fresh air |
Determine based on purpose, personnel and project design requirements |
Cooperate with pressure difference control |
Coordinate with exhaust, return air, building air tightness and control strategies |
Dealing with new rheumatic load |
Clarify outdoor air conditions, supply air moisture content or dew point requirements |
Reduce backend filtering load |
Determine unit filtration configuration according to system filtration division |
Adapt to operational changes |
Check the adjustment range, start and stop sequence and necessary linkage |
functional segment |
Main function |
Configuration basis |
|---|---|---|
Fresh air inlet and damper |
Bringing in and conditioning outdoor air |
Air volume, installation location and linkage requirements |
hierarchical filter section |
Filter particulate matter entering the system |
Outdoor air conditions and back-end filtration requirements |
preheating section |
Preheat low-temperature fresh air as needed |
Winter design conditions and antifreeze solutions |
Cooling and dehumidification section |
Cool the air and dehumidify it according to design conditions |
Cold source conditions, supply air moisture content or dew point target |
reheat section |
Adjust the supply air temperature after dehumidification as needed |
Treatment process and heat source conditions |
Humidification section |
Supplement air humidity as needed |
Winter working conditions, humidification amount and water vapor conditions |
fan section |
Provide the power required by the unit and external air ducts |
Air volume, internal resistance and external static pressure |
Maintenance and monitoring configuration |
Supports cleaning, maintenance and status checks |
Component layout, sensor and alarm requirements |
Each functional section is selected according to the project, and the actual process and scope of supply are subject to the technical plan.
Aili Industrial has the capabilities of motor manufacturing and independent research and development and production of fans. It can match the fan working point based on the design air volume, filter and coil resistance, external static pressure and speed regulation requirements.
For fresh air systems that need to be adjusted according to the exhaust air or operating mode, the fan adjustment range, low-load operation and control mode can be checked simultaneously to align component selection with project operation requirements.
Relying on its air filter manufacturing capabilities, Aili Industrial can jointly confirm the filtration level, rated air volume, installation size, sealing and replacement space with the overall machine structure, and check the impact of changes in filter resistance on the fan.
When it comes to the control of gaseous pollutants, chemical filtration solutions can be communicated separately. Evaluation should be based on target pollutants, concentration, temperature and humidity, and treatment air volume. Particulate matter filtering configuration cannot be used to replace gaseous pollutant control.
Aili Industrial has sheet metal processing and complete machine assembly capabilities. It can combine the size of the machine room, transportation channels, functional section layout and maintenance requirements to communicate the box segmentation, air outlet position, connection direction and maintenance side.
For multiple unit projects, the structure, interfaces and spare parts specifications can be uniformly checked to facilitate on-site installation and subsequent maintenance management.
Aili Industrial has the ability to develop control system software and hardware, and can communicate fan speed adjustment, damper linkage, temperature and humidity adjustment, filter pressure difference prompts and abnormal alarms as needed.
When it is necessary to connect to exhaust, cold and heat sources or project monitoring systems, the sensor location, control logic, signal type and communication interface can be clarified during the planning stage, and the specific functions will be implemented according to the confirmed configuration.
Aili industrial products cover MAU matching air conditioning boxes, fan boxes, FFU, EFU, HEPA/ULPA filters, chemical filters and high-efficiency air supply outlets. Fresh air treatment and terminal equipment can be checked under the same project conditions.
Relying on the R&D and manufacturing collaboration between Suzhou and Guangde, it can cooperate with solution confirmation, component production, sheet metal processing, complete machine assembly and testing, and support project customization and batch delivery.
In a system using MAU + FFU + dry coil, the following division of labor can be understood; the specific load distribution and air path should be subject to the project design.
equipment |
Main tasks |
Parameters that need to be coordinated |
|---|---|---|
MAU fresh air treatment unit |
Handle outdoor fresh air and bear the designed distribution of fresh air and moisture loads |
Fresh air volume, air supply status, static pressure and adjustment range |
FFU fan filter unit |
Provide circulating filtered air supply in clean areas |
Circulating air volume, filtration efficiency and system resistance |
Dry Coil (DCC) |
Handle part of the sensible heat load under design dry conditions |
Water temperature, air dew point, heat transfer capacity and condensation control |
MAU air volume and FFU circulating air volume should be calculated separately; MAU supply air temperature, moisture content and dry coil water temperature also need to be coordinated and confirmed.
Parameter items |
Configuration instructions |
Parameter items |
Configuration instructions |
|---|---|---|---|
Design fresh air volume |
Determine based on fresh air, supplementary air and system balance needs |
External static pressure |
Determine based on external air path resistance |
outdoor design conditions |
Determined according to the design information of the project location |
Target air supply status |
Specify temperature, moisture content or dew point requirements |
Hot and cold processing capabilities |
Calculated according to design working conditions and load |
Cold and heat source conditions |
Confirm water temperature, flow or other energy parameters |
Filter configuration |
Determine the division of labor according to system filtering |
Fans and motors |
Match according to working point and speed regulation requirements |
Box and insulation |
Determined according to operating temperature difference and installation environment |
drainage structure |
Designed based on condensation water and pressure conditions |
Maintain configuration |
Confirm the access side and component extraction space |
Control and linkage |
Determined according to operation strategy and project interface |
The specific air volume, power, cooling heat, control accuracy, noise and size are subject to the confirmed selection data.
Application scenarios |
Supporting concerns |
|---|---|
Semiconductor and electronic clean factory |
Exhaust air supply, humidity treatment and circulation system coordination |
Panel display and precision optical production area |
Fresh air filtration, air supply status and operation adjustment |
Medical device and biomedicine workshop |
Fresh air treatment, filtration division of labor and maintenance requirements |
Clean room expansion and system modification |
Original cold and heat sources, air ducts and control compatibility |
The FFU fan filter unit
combines the circulating air volume, filtration requirements and control method selection of the clean area, and checks the operation tasks with the MAU respectively.
HEPA/ULPA air filters
determine efficiency, air volume, resistance and sealing structure according to the installation location, taking into account filtration performance and maintenance requirements.
The high-efficiency air supply port
is used in the corresponding duct-type terminal filter air supply system, and the single-port air volume, interface and installation form can be confirmed simultaneously.
MAU is also an air handling equipment. Clean room projects pay more attention to the balance of supply air, the moisture content or dew point of the supply air, the division of filtration and the linkage with the circulation system. The specific differences depend on the technical requirements and configuration.
It is usually necessary to distinguish between fresh air volume and circulating air volume. The MAU undertakes the fresh air treatment tasks assigned by the design, and the circulating filtered air supply can be undertaken by the FFU or other equipment.
Humidity-related requirements need to be clarified at the same time. Especially when there is a dehumidification task, the moisture content, dew point or temperature and humidity conditions that can be used for calculation should be provided, and the cold source capacity should be checked.
The pressure difference needs to be coordinated by air supply, exhaust, leakage and control strategies. The MAU is part of the system and should be designed and commissioned together with other equipment and building conditions.
The filtration level and location are determined by the system design and need to be selected based on the back-end FFU or terminal filtration equipment, outdoor air conditions, system resistance and maintenance methods.
The air volume, filtration, structure and control requirements of the unit and FFU can be checked simultaneously according to project requirements. The specific scope of supply and interfaces are specified in the technical plan.
Provide fresh air volume, exhaust conditions, external static pressure, outdoor design conditions, target air supply status, cold and heat sources and installation dimensions to facilitate further determination of equipment configuration. If you already have FFU, dry coil or circulation system data, you can submit it for verification together.
Contact Aili Industrial immediately to obtain clean room MAU product information and selection support.
→ Submit fresh air and exhaust air supply requirements → Consult filtration and temperature and humidity treatment configuration
→ Communicate about MAU and FFU system matching → Learn about non-standard customization and batch project support
Aili Industry - From motors, fans and filters to sheet metal, control and complete machine assembly, it provides collaborative manufacturing and technical support for clean room fresh air treatment projects.