| Status: | |
|---|---|
| Quantity: | |
To meet the needs of clean air treatment, we combine filtration, temperature and humidity treatment, air supply and control.
Aili industrial purification type combined air conditioning box, also known as combined purification air conditioning unit, is an air treatment equipment used in clean rooms and industrial purification systems. Functional sections such as filtration, surface cooling, heating, humidification, air supply and maintenance can be combined according to project requirements to process fresh air, return air or mixed air, and be matched with rear-end air ducts and end-end filter air supply equipment.
The selection of purified air-conditioning boxes requires simultaneous consideration of air handling capacity, filter resistance, box sealing, cleaning maintenance and control linkage. Aili Industrial relies on motors, fans, air filters, control systems, sheet metal and complete machine manufacturing capabilities to match related components under the same project conditions to provide support for equipment configuration, installation and subsequent maintenance.
→ Configure hierarchical filtration on demand → Flexible combination of air treatment functions
→ Collaborative matching of core components → Support non-standard customization of projects
The purification combined air-conditioning box can determine the treatment process according to the inlet air conditions, target air supply status and system design requirements. The sequence and specifications of each functional section need to be calculated based on actual working conditions.
Function module |
Configuration content |
Selection concerns |
|---|---|---|
New return air treatment |
Fresh air, return air or mixed air interface and damper |
Fresh air ratio, interface location and operation mode |
Hierarchical filtering |
Initial effect, medium effect and other filtering configurations required by the project |
Filtration efficiency, installation seal, resistance and replacement space |
Cooling and dehumidification |
Configuring table cooling coil and drainage structure as required |
Air inlet and outlet status, cold source conditions, condensate water discharge |
Heating and reheating |
Configure according to project heat source conditions |
Preheating, supply air temperature and reheating requirements after dehumidification |
Humidification treatment |
Select humidification method according to humidity target |
Humidification amount, water vapor conditions and maintenance requirements |
Fan air supply |
Matching fans, motors and speed regulation methods |
Air volume, system resistance and operating time |
Inspection and maintenance |
Access doors, observation windows and operating spaces |
Filter replacement, component inspection and internal cleaning |
Control monitoring |
Configure sensors, pressure difference monitoring and linkage interfaces as needed |
Control logic, alarm requirements and system compatibility |
The above are optional configurations, and the scope of supply of different projects is subject to the confirmed technical solution.
Aili Industrial has the capability of independent R&D and production of motors and fans, which can be matched based on the target air volume, internal resistance of the unit, external static pressure and speed regulation requirements.
For the situation where the resistance increases after the filter is used, the fan adjustment range and operating margin can be checked during the selection stage to reduce the configuration deviation caused by selecting based only on the rated air volume.
Aili Industrial has the ability to manufacture air filters and can confirm the filter size, filtration grade, head wind speed, initial resistance and installation method together with the air conditioning box structure.
needs and endsHEPA/ULPA filters are matched, the configuration can be determined based on the filtration division of the entire air supply system. When Projects involving gaseous pollutant control can also be communicated separatelyChemical filter solutions are evaluated based on target pollutants and working conditions.
Relying on its sheet metal processing and complete machine assembly capabilities, Aili Industrial can adjust the box size, segmentation form, air outlet position and maintenance side according to the on-site space.
When designing the structure, the filter extraction direction, fan maintenance space, coil cleaning and transportation conditions are simultaneously considered to make the equipment layout more suitable for on-site use needs.
Aili Industrial has the ability to develop control system software and hardware, and can communicate fan start and stop, speed regulation, temperature and humidity adjustment, filter pressure difference prompts and external equipment linkage according to project requirements.
Specific sensors, actuators, communication protocols and interface forms are confirmed during the planning stage to facilitate connection with the project control system.
Aili industrial products cover air conditioning boxes, fan boxes,FFU fan filter unit、Chemical filters FFU , HEPA/ULPA filters, chemical filters and high-efficiency air supply vents, etc. can be used to simultaneously check the parameters of air treatment equipment and end products according to project needs.
The collaboration of independent manufacturing links also facilitates the organization of materials, production, assembly and testing around the confirmed plan, and supports prototype development, project batch delivery and subsequent spare parts matching.
Parameter items |
Configuration instructions |
Parameter items |
Configuration instructions |
|---|---|---|---|
Design air volume |
Determined according to project air supply needs |
External static pressure |
Determine based on external air path resistance |
New return air ratio |
Determine according to system design |
Filter configuration |
Select according to inlet air and system requirements |
Hot and cold processing capabilities |
Calculated according to design conditions |
Humidity treatment |
Configure dehumidification, reheat or humidification on demand |
Cabinet size |
Combined with functional segments and space determination |
Cabinet material |
Choose according to usage environment and cleaning requirements |
Insulation and sealing |
Designed according to temperature difference and project requirements |
Wind inlet and outlet position |
Determine according to the direction of the air duct and the interface |
Fans and motors |
Match according to working point and speed regulation requirements |
Maintenance direction |
Determined by on-site maintenance space |
Control method |
Configuration by operating mode and interface |
Power supply conditions |
Determined by project power source and selected components |
The specific air volume, power, cooling and heat quantity, noise and overall dimensions are subject to the product selection data and confirmation plan.
Application scenarios |
Supporting concerns |
|---|---|
Semiconductor and electronic clean factory |
Air treatment process, filtration configuration, continuous operation and terminal support |
Precision optics and instrument production area |
Particle control, temperature and humidity requirements and air supply stability |
Medical device and biomedicine workshop |
Filtration, internal cleaning, drainage and ease of maintenance |
Food and cosmetics production workshop |
Fresh air supplement, filtration configuration and production environment requirements |
Laboratory and testing areas |
Fresh air and return air treatment, temperature and humidity requirements and operation linkage |
Renovation of the original purification system |
Existing space, duct interfaces, system resistance and control compatibility |
The purifying combined air-conditioning box is responsible for the air treatment tasks in the system, and the terminal filtration and air supply equipment are configured according to the requirements of the clean area. When selecting, you can check the following products simultaneously:
The FFU fan filter unit
is suitable for clean room ceilings, clean sheds and local clean areas. It can check the circulating air volume, filter resistance and control method according to the system form.
HEPA/ULPA air filters
are used in corresponding filtration positions, and the configuration is determined based on target efficiency, rated air volume, installation size and sealing method.
The high-efficiency air supply outlet
is suitable for duct-type end filter air supply, and can be matched by combining the number of air outlets, single air volume, interface and installation method.
Both can adopt functional segment combination structures. The purification type pays more attention to air filtration, filter installation and sealing, internal cleaning of the box, condensate water treatment and maintenance conditions. Specific differences should be confirmed through the configuration list and technical requirements.
uncertain. The grade and location of the filter are determined by the system design, and the high-efficiency filter can also be placed in the terminal FFU or high-efficiency air supply port. It is necessary to combine the filtration division, system resistance and maintenance method selection.
The cleanliness level is jointly affected by air treatment, terminal filtration, air supply volume, air flow organization, envelope structure and operation management, and needs to be confirmed through overall design, debugging and testing.
Can communicate and coordinate according to project needs. Aili Industry has relevant R&D and manufacturing capabilities, and can determine the configuration based on the air volume and static pressure of the entire machine, filter resistance, installation size and operation mode. The specific scope of supply is specified in the technical plan.
You can submit on-site dimensions, air duct diagrams and technical requirements, and evaluate customized solutions based on functional section length, air inlet and outlet locations, transportation channels and maintenance spaces.
The purification type combined air-conditioning box needs to be designed together with the filtration division of labor, temperature and humidity treatment process and terminal air supply method of the clean system. Clarifying the air volume and static pressure, air inlet and outlet status, cold and heat sources, filtration requirements and installation conditions will help determine the appropriate configuration.
Contact Aili Industrial immediately to obtain product information and selection support for purification type combined air-conditioning boxes.
→ Submit the project air volume and static pressure requirements → Consult the filtration and temperature and humidity treatment configuration
→ Communicate the box size and installation interface → Understand the complete machine matching and mass customization
Aili Industry - From motors, fans, filters to sheet metal, control and complete machine assembly, it provides collaborative manufacturing and technical support for clean air treatment projects.