Vertical air conditioning box

Aili industrial vertical air-conditioning box is suitable for machine rooms and industrial air treatment areas with installation height and required area for control equipment. It can be configured according to fresh air, return air or mixed air conditions, and the fan, filter, hot and cold treatment unit and box structure can be selected together to support project matching and non-standard customization.
Status:
Quantity:

Vertical air conditioning box

Make use of height space and configure air treatment equipment based on air volume, filtration and installation conditions.

Aili industrial vertical air-conditioning box, also known as vertical air handling unit or vertical air hood, adopts a floor-standing vertical box structure. It can be equipped with filtering, cooling, heating and air supply units according to project requirements, and is used to process fresh air, return air or mixed air.

For equipment areas with limited plane space and corresponding installation height, the vertical structure can be used as the selection direction. The size of the equipment needs to be determined based on the processing air volume, component layout, air duct connection and maintenance requirements, while leaving space for top pipes, side piping and maintenance operations.

Aili Industrial has motors, fans, control systems, air filters, sheet metal processing and complete machine assembly capabilities. It can jointly check air supply performance, filter resistance, box size and control requirements, and provide selection and customization support for industrial plants and clean room supporting projects.

→ Vertical layout utilizes height space → The position of the air outlet is determined according to on-site conditions
→ Fans and filters are coordinated and matched → Supports customization of size and control functions

Vertical-Air-Handling-Unit_Vertical air conditioning box——Aili Industry.jpg

Vertical structure, taking into account both land occupation and maintenance

When selecting a vertical air-conditioning box, the equipment footprint, height, air duct connection and maintenance space should also be checked. The cabinet can adopt different component layouts, and the air inlet and outlet locations and maintenance directions need to be clarified in the planning stage.

On-site requirements

Configuration and design concerns

Flat installation space is limited

Evaluate vertical layout based on height conditions and retain necessary maintenance access

The air duct is located above the equipment

Check the top air outlet, pipe height and air duct support conditions

Equipment installed against the wall

Confirm the access surface, filter extraction direction and takeover operation space

Original equipment replacement

Check the foundation, air volume, static pressure, cold and heat sources and original interfaces

Centralized arrangement of multiple devices

Coordinate maintenance channels, pipeline directions and electronic control operating positions

Features

Fans are matched according to actual system resistance

Vertical air conditioning boxes need to overcome the resistance of filters, coils, internal air ducts and external air duct systems. When selecting the model, clearly design the air volume and external static pressure, and then determine the fan operating point, motor power and speed regulation method.

Relying on its independent R&D and production capabilities in motor manufacturing and fans, Aili Industrial can communicate configurations based on project operation periods and adjustment needs, and check the impact of changes in filter resistance on air supply.

Synchronous confirmation of filter and box structure

According to the air source, system filtration division and back-end equipment requirements, select the filter grade, size and installation method, and reserve space for replacement.

Aili Industrial has the ability to manufacture air filters, and can jointly confirm the filter resistance, installation sealing and extraction direction with the overall machine structure to facilitate equipment matching and subsequent supply of consumables.

Hot and cold treatment is configured according to project conditions

When cooling or heating is required, the processing capacity should be calculated based on the inlet air status, target air supply status, and cold and heat source conditions. When using a cold water coil solution, it is necessary to simultaneously confirm the water supply and return parameters, connection location, condensate discharge and insulation requirements.

Humidification, dehumidification or reheating are on-demand configurations and should be determined based on the actual air treatment process.

On-site layout of air outlets and interfaces

According to the direction of the air duct, the height of the machine room, the location of the pipeline and the maintenance requirements, the air inlet and outlet interfaces, access doors and pipe connections can be communicated.

Relying on sheet metal processing and complete machine assembly capabilities, Aili Industrial can make matching adjustments to the box structure and interfaces to support non-standard projects with clear installation conditions.

Coordination of control functions and operating modes

Can communicate fan start and stop, speed adjustment, temperature adjustment, filter pressure difference prompts and external equipment linkage according to project needs.

Aili Industrial has the ability to develop control system software and hardware, and can determine the control logic based on the selected components and project interfaces. The specific functions, sensors and communication protocols are specified in the technical plan.

Aili Industrial's manufacturing and supporting advantages

Collaboration of core components reduces selection deviations

Aili Industry covers motors, fans, filters, control systems, sheet metal and complete machine assembly. It can check air volume and static pressure, filter resistance, structural interfaces and control methods around the same project, reducing matching problems caused by separate selection of components.

Independent processing to facilitate the implementation of customized requirements

For projects that have special requirements for box size, air inlet and outlet direction, or maintenance space, the structure can be adjusted based on the installation drawings. The design, sheet metal processing and assembly links are coordinated to facilitate the implementation of confirmation requirements into equipment manufacturing.

Suzhou and Guangde collaborate to support project delivery

Relying on the R&D and manufacturing cooperation between Suzhou and Guangde, Aili Industrial can coordinate component selection, structural design, control development, production assembly and testing, and provide support for prototypes, project procurement and batch supply.

For multiple equipment projects, the configuration, interface and spare parts requirements can be uniformly checked to facilitate subsequent operation and maintenance.

Synchronous matching of various cleaning equipment

The vertical air conditioning box can be designed according to the system, and can be matched with Aili Industrial'sFFU fan filter unit、HEPA/ULPA air filters andCollaborative selection of high-efficiency air supply outlets confirms the parameter relationship between air treatment and terminal filtered air supply.

Product parameters and optional configurations

Parameter items

Configuration instructions

Parameter items

Configuration instructions

Structural form

Floor standing vertical structure

air source

Fresh air, return air or mixed air

Design air volume

Determined according to project air supply needs

External static pressure

Determined by external system resistance

Filter configuration

Select according to system requirements

Hot and cold treatment

Calculated based on air conditions and cold and heat source conditions

Fans and motors

Match according to working point and speed regulation requirements

Cabinet material

Choose according to usage environment and cleaning requirements

Cabinet size

Determine based on components and installation space

Insulation and sealing

Configure according to operating temperature difference and project requirements

Wind inlet and outlet position

Determine according to the air duct interface and air flow path

Maintenance direction

Determine according to maintenance access and component replacement requirements

Take over direction

Determine according to pipeline layout

Control method

Configuration by operating mode and system interface

The specific air volume, power, cooling and heat quantity, noise and overall dimensions are subject to the confirmed selection data.

Applicable scenarios

Application scenarios

main focus

Industrial plants and production workshops

Air filtration, hot and cold treatment and centralized air supply

Electronics and precision manufacturing area

Filter configuration, temperature requirements and interface matching

Clean room air treatment package

System filtration division of labor, air volume and terminal equipment coordination

Laboratory and testing areas

Handle fresh air, return air or mixed air according to project design

Renovation of original equipment

Original installation space, heating and cooling sources, ducts and controls compatibility

Vertical air conditioning box selection information

Provide the following information to further determine the configuration:

Air parameters: design air volume, external static pressure, fresh return air ratio and air inlet and outlet status.
**Cold and heat source conditions: **Supply and return water temperature, available water volume or other heat source parameters.
**Site dimensions:** Available length, width and height of the equipment, transportation channels, foundation and top pipe space.
**Filtration requirements:**Filtration level, installation seal and replacement method.
**Interface requirements:** Air duct, water pipe, power supply, maintenance side and control functions.

The original equipment nameplate, on-site photos and interface drawings are available and can be submitted simultaneously to check replacement conditions.

FAQ

Are vertical air-conditioning boxes more space-saving than horizontal air-conditioning boxes?

Vertical structures can utilize height space, but the actual footprint depends on air volume, component configuration and maintenance requirements. Ducts, nozzles, and service access should be considered together when comparing.

Does a vertical air-conditioning box have to have air inlet from the bottom and air outlet from the top?

uncertain. The location of the air inlet and outlet needs to be determined based on the internal component layout and on-site air duct conditions. The air flow direction and interfaces should be clarified by confirming the drawings.

Does the vertical air conditioning box have its own refrigeration system?

uncertain. When using a cold water coil, you need to connect to an external cold water system; if you need to bring your own compressor for refrigeration, you should separately confirm the direct expansion configuration.

Can it be made according to the dimensions of the original vertical wind cabinet?

Original equipment data can be provided for evaluation. In addition to the external dimensions, it is also necessary to check the air volume, static pressure, hot and cold treatment capacity, filtration configuration and maintenance space to determine the replacement plan.

How to arrange subsequent filter and fan maintenance?

The location of the access door, the direction of filter extraction and the fan maintenance method should be determined during the design stage, and the operating space should be reserved. Aili Industrial can simultaneously confirm component specifications and spare parts matching requirements.

Vertical air conditioning box selection and technical consultation

The vertical air conditioning box needs to match the site height, air duct layout, cold and heat sources and operation requirements. Clarifying air volume and static pressure, air treatment targets, interface locations and maintenance conditions in advance can help reduce installation adjustments.

Contact Aili Industrial immediately to obtain product information and selection support for vertical air conditioning boxes.

→ Submit equipment size and installation requirements → Consult air volume, static pressure and filtration configuration
→ Communicate about original equipment replacement and interface adjustment → Understand non-standard customization and batch project matching

Aili Industry - From motors, fans and filters to sheet metal, control and complete machine assembly, it provides collaborative manufacturing and technical support for vertical air treatment equipment.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.