Make use of height space and configure air treatment equipment based on air volume, filtration and installation conditions.
Aili industrial vertical air-conditioning box, also known as vertical air handling unit or vertical air hood, adopts a floor-standing vertical box structure. It can be equipped with filtering, cooling, heating and air supply units according to project requirements, and is used to process fresh air, return air or mixed air.
For equipment areas with limited plane space and corresponding installation height, the vertical structure can be used as the selection direction. The size of the equipment needs to be determined based on the processing air volume, component layout, air duct connection and maintenance requirements, while leaving space for top pipes, side piping and maintenance operations.
Aili Industrial has motors, fans, control systems, air filters, sheet metal processing and complete machine assembly capabilities. It can jointly check air supply performance, filter resistance, box size and control requirements, and provide selection and customization support for industrial plants and clean room supporting projects.
→ Vertical layout utilizes height space → The position of the air outlet is determined according to on-site conditions
→ Fans and filters are coordinated and matched → Supports customization of size and control functions
When selecting a vertical air-conditioning box, the equipment footprint, height, air duct connection and maintenance space should also be checked. The cabinet can adopt different component layouts, and the air inlet and outlet locations and maintenance directions need to be clarified in the planning stage.
On-site requirements |
Configuration and design concerns |
|---|---|
Flat installation space is limited |
Evaluate vertical layout based on height conditions and retain necessary maintenance access |
The air duct is located above the equipment |
Check the top air outlet, pipe height and air duct support conditions |
Equipment installed against the wall |
Confirm the access surface, filter extraction direction and takeover operation space |
Original equipment replacement |
Check the foundation, air volume, static pressure, cold and heat sources and original interfaces |
Centralized arrangement of multiple devices |
Coordinate maintenance channels, pipeline directions and electronic control operating positions |
Vertical air conditioning boxes need to overcome the resistance of filters, coils, internal air ducts and external air duct systems. When selecting the model, clearly design the air volume and external static pressure, and then determine the fan operating point, motor power and speed regulation method.
Relying on its independent R&D and production capabilities in motor manufacturing and fans, Aili Industrial can communicate configurations based on project operation periods and adjustment needs, and check the impact of changes in filter resistance on air supply.
According to the air source, system filtration division and back-end equipment requirements, select the filter grade, size and installation method, and reserve space for replacement.
Aili Industrial has the ability to manufacture air filters, and can jointly confirm the filter resistance, installation sealing and extraction direction with the overall machine structure to facilitate equipment matching and subsequent supply of consumables.
When cooling or heating is required, the processing capacity should be calculated based on the inlet air status, target air supply status, and cold and heat source conditions. When using a cold water coil solution, it is necessary to simultaneously confirm the water supply and return parameters, connection location, condensate discharge and insulation requirements.
Humidification, dehumidification or reheating are on-demand configurations and should be determined based on the actual air treatment process.
According to the direction of the air duct, the height of the machine room, the location of the pipeline and the maintenance requirements, the air inlet and outlet interfaces, access doors and pipe connections can be communicated.
Relying on sheet metal processing and complete machine assembly capabilities, Aili Industrial can make matching adjustments to the box structure and interfaces to support non-standard projects with clear installation conditions.
Can communicate fan start and stop, speed adjustment, temperature adjustment, filter pressure difference prompts and external equipment linkage according to project needs.
Aili Industrial has the ability to develop control system software and hardware, and can determine the control logic based on the selected components and project interfaces. The specific functions, sensors and communication protocols are specified in the technical plan.
Aili Industry covers motors, fans, filters, control systems, sheet metal and complete machine assembly. It can check air volume and static pressure, filter resistance, structural interfaces and control methods around the same project, reducing matching problems caused by separate selection of components.
For projects that have special requirements for box size, air inlet and outlet direction, or maintenance space, the structure can be adjusted based on the installation drawings. The design, sheet metal processing and assembly links are coordinated to facilitate the implementation of confirmation requirements into equipment manufacturing.
Relying on the R&D and manufacturing cooperation between Suzhou and Guangde, Aili Industrial can coordinate component selection, structural design, control development, production assembly and testing, and provide support for prototypes, project procurement and batch supply.
For multiple equipment projects, the configuration, interface and spare parts requirements can be uniformly checked to facilitate subsequent operation and maintenance.
The vertical air conditioning box can be designed according to the system, and can be matched with Aili Industrial'sFFU fan filter unit、HEPA/ULPA air filters andCollaborative selection of high-efficiency air supply outlets confirms the parameter relationship between air treatment and terminal filtered air supply.
Parameter items |
Configuration instructions |
Parameter items |
Configuration instructions |
|---|---|---|---|
Structural form |
Floor standing vertical structure |
air source |
Fresh air, return air or mixed air |
Design air volume |
Determined according to project air supply needs |
External static pressure |
Determined by external system resistance |
Filter configuration |
Select according to system requirements |
Hot and cold treatment |
Calculated based on air conditions and cold and heat source conditions |
Fans and motors |
Match according to working point and speed regulation requirements |
Cabinet material |
Choose according to usage environment and cleaning requirements |
Cabinet size |
Determine based on components and installation space |
Insulation and sealing |
Configure according to operating temperature difference and project requirements |
Wind inlet and outlet position |
Determine according to the air duct interface and air flow path |
Maintenance direction |
Determine according to maintenance access and component replacement requirements |
Take over direction |
Determine according to pipeline layout |
Control method |
Configuration by operating mode and system interface |
The specific air volume, power, cooling and heat quantity, noise and overall dimensions are subject to the confirmed selection data.
Application scenarios |
main focus |
|---|---|
Industrial plants and production workshops |
Air filtration, hot and cold treatment and centralized air supply |
Electronics and precision manufacturing area |
Filter configuration, temperature requirements and interface matching |
Clean room air treatment package |
System filtration division of labor, air volume and terminal equipment coordination |
Laboratory and testing areas |
Handle fresh air, return air or mixed air according to project design |
Renovation of original equipment |
Original installation space, heating and cooling sources, ducts and controls compatibility |
Provide the following information to further determine the configuration:
Air parameters: design air volume, external static pressure, fresh return air ratio and air inlet and outlet status.
**Cold and heat source conditions: **Supply and return water temperature, available water volume or other heat source parameters.
**Site dimensions:** Available length, width and height of the equipment, transportation channels, foundation and top pipe space.
**Filtration requirements:**Filtration level, installation seal and replacement method.
**Interface requirements:** Air duct, water pipe, power supply, maintenance side and control functions.
The original equipment nameplate, on-site photos and interface drawings are available and can be submitted simultaneously to check replacement conditions.
Vertical structures can utilize height space, but the actual footprint depends on air volume, component configuration and maintenance requirements. Ducts, nozzles, and service access should be considered together when comparing.
uncertain. The location of the air inlet and outlet needs to be determined based on the internal component layout and on-site air duct conditions. The air flow direction and interfaces should be clarified by confirming the drawings.
uncertain. When using a cold water coil, you need to connect to an external cold water system; if you need to bring your own compressor for refrigeration, you should separately confirm the direct expansion configuration.
Original equipment data can be provided for evaluation. In addition to the external dimensions, it is also necessary to check the air volume, static pressure, hot and cold treatment capacity, filtration configuration and maintenance space to determine the replacement plan.
The location of the access door, the direction of filter extraction and the fan maintenance method should be determined during the design stage, and the operating space should be reserved. Aili Industrial can simultaneously confirm component specifications and spare parts matching requirements.
The vertical air conditioning box needs to match the site height, air duct layout, cold and heat sources and operation requirements. Clarifying air volume and static pressure, air treatment targets, interface locations and maintenance conditions in advance can help reduce installation adjustments.
Contact Aili Industrial immediately to obtain product information and selection support for vertical air conditioning boxes.
→ Submit equipment size and installation requirements → Consult air volume, static pressure and filtration configuration
→ Communicate about original equipment replacement and interface adjustment → Understand non-standard customization and batch project matching
Aili Industry - From motors, fans and filters to sheet metal, control and complete machine assembly, it provides collaborative manufacturing and technical support for vertical air treatment equipment.