Horizontally arranged, the air supply, filtration and air treatment configurations are matched according to the on-site space.
Aili industrial horizontal air conditioning box, also known as horizontal air handling unit, is an air handling equipment with horizontal layout. Filters, fans, cold water coils, heating and other processing units can be configured according to project needs to filter, cool, heat and transport fresh air, return air or mixed air.
The horizontal structure facilitates the connection of equipment and air ducts according to the layout of the computer room. When selecting, you need to check the equipment height, floor space, air outlet location, pipeline interfaces and maintenance space at the same time to ensure that the equipment installation and subsequent maintenance have corresponding conditions.
Aili Industrial has motors, fans, air filters, control systems, sheet metal processing and complete machine assembly capabilities. It can collaboratively determine component and structural configurations based on project conditions, and supports standard selection and non-standard customization.
→ Horizontal structure facilitates floor layout → Air outlet and maintenance direction can be determined as needed
→ Fan and filter configurations match → Support box and control interface customization
Horizontal air conditioning boxes are suitable for equipment areas with horizontal installation space. The length, width and height of the equipment need to be determined based on the air volume, functional configuration and maintenance methods.
site conditions |
Design and selection concerns |
|---|---|
Available height is limited |
Evaluate the cabinet height while meeting the air volume, head-on wind speed and component installation requirements. |
The air ducts are arranged horizontally |
Check the air inlet and outlet direction, interface size and air duct connection space |
Equipment installed against the wall |
Determine the inspection side in advance and reserve space for panel opening and component extraction. |
Original equipment replacement and modification |
Check the original foundation, air ducts, water pipes, power supply and transportation channels |
Need to be transported in stages |
Evaluate segmented forms and on-site connection methods based on access and loading and unloading conditions |
Horizontal is the structural form, and the floor or hoisting method needs to be confirmed according to the specific machine model, load-bearing structure and installation plan.
When selecting equipment, consider the resistance of filters, coils, and internal air paths, as well as the resistance of external air ducts, valves, and terminal equipment, and then determine the fan operating point.
Aili Industrial can combine its independent research and development and production of fans with its motor manufacturing capabilities to check the target air volume, static pressure and speed regulation requirements to avoid judging the air supply capacity based on motor power alone.
Select the filtration configuration based on the inlet air conditions and back-end system requirements, and simultaneously confirm the filter size, installation seal, extraction direction and pressure differential monitoring requirements.
Relying on its air filter manufacturing capabilities, Aili Industrial can check the filter resistance and fan configuration together to facilitate machine selection and subsequent consumable matching.
According to the direction of the air duct, the location of the pipeline and the equipment maintenance requirements, the layout of the air inlet and outlet, coil pipe connection, electrical control position and maintenance panel can be communicated.
Aili Industrial's sheet metal processing and complete machine assembly capabilities help implement on-site interface requirements into the box structure and provide support for non-standard sizes and modification projects.
When cooling or heating is required, the corresponding processing unit is selected based on the air inlet and outlet status, load, and cold and heat source conditions. When using cold water coils, simultaneously confirm the water supply and return conditions, condensate discharge and insulation requirements.
Projects that require dehumidification, reheating or humidification should be separately calculated based on the target air status to determine the corresponding configuration.
Can communicate start-stop, speed adjustment, temperature adjustment, filter pressure difference prompts and equipment linkage functions according to project requirements.
Aili Industrial has the ability to develop control system software and hardware, and can determine the control logic based on the selected motors, sensors and execution components. The specific functions and communication interfaces are confirmed in the planning stage.
Parameter items |
Configuration instructions |
Parameter items |
Configuration instructions |
|---|---|---|---|
Structural form |
Horizontal horizontal layout |
Installation method |
Confirm according to specific structure and site conditions |
Design air volume |
Determine based on system air supply volume |
External static pressure |
Determined based on external system resistance |
air source |
Fresh air, return air or mixed air |
Filter configuration |
Select according to system filtering requirements |
cooling configuration |
Configure units such as cold water coils as needed |
Heating configuration |
Choose according to heat source and processing needs |
Cabinet size |
Determine based on air volume, configuration and space |
Materials and insulation |
Select according to environment and usage requirements |
Fans and motors |
Match according to working point, power supply and speed regulation requirements |
Air inlet and outlet interface |
Determine according to on-site air duct conditions |
Maintenance direction |
Determine according to operating space and component maintenance requirements |
Control method |
Configure according to operating mode and interface requirements |
Specific air volume, power, cooling heat, noise and size are subject to the confirmed selection data.
Aili's industrial manufacturing system covers motors, fans, control systems, sheet metal, air filters and complete machine assembly. It can check the fan operating point, filter resistance, structural dimensions and control requirements in the same plan, reducing matching deviations after separate selection of each component.
For projects where the original equipment is replaced, the space in the computer room is limited, or the air duct interface is fixed, the box size, maintenance side and interface adjustment plan can be communicated based on the on-site drawings, taking into account the equipment operation and installation and maintenance conditions.
Relying on the R&D and manufacturing collaboration between Suzhou and Guangde, components, processing, assembly and testing can be arranged around the confirmed plan. For multiple equipment projects, the configuration, interface direction and control requirements can be uniformly checked to facilitate project procurement and subsequent maintenance management.
The horizontal air conditioning box can be combined with Aili Industrial's according to the system form.FFU fan filter unit、HEPA/ULPA air filters and other products are selected collaboratively to confirm the parameter relationship between air treatment and terminal filtration and air supply.
Application scenarios |
Main needs |
|---|---|
Industrial plants and production workshops |
Air filtration, hot and cold treatment and centralized air supply |
Electronics and precision manufacturing area |
Filter configuration, ambient temperature and device interface matching |
Clean room air treatment package |
Coordinate with system filtration division, terminal equipment and air volume configuration |
Laboratory and testing areas |
Handle fresh air, return air or mixed air according to design requirements |
Renovation of existing air conditioning system |
Adapt to original installation space, pipelines and control conditions |
Air parameters: design air volume, external static pressure, fresh air ratio and air inlet and outlet status.
**Hot and cold source conditions:** Cold water, hot water or other heat source parameters, and available flow rate.
**Filtration requirements:**Filtration level, installation method and replacement requirements.
**Installation conditions: **Available dimensions, foundation location, transport access and access space.
**Interface information:** Air duct, water pipe, power supply and control system requirements.
On-site photos, original equipment nameplates or installation drawings can also be provided to verify replacement and modification conditions.
The selection is mainly based on the site space, air duct connection and maintenance conditions. The horizontal type usually requires a larger flat installation space; the vertical type focuses on utilizing height space. The air handling capacity of both needs to be calculated based on the actual configuration.
Need to confirm according to the specific model. The floor-standing horizontal structure cannot be directly regarded as a hoistable product. Hoisting requires checking the load-bearing frame, lifting points, vibration reduction and maintenance conditions.
uncertain. The products on this page are selected according to the cold and heat source conditions of the project; when using cold water coils, an external cold water system needs to be connected. Products that require their own refrigeration system should separately confirm the direct expansion configuration.
You can submit the original equipment size and interface information for evaluation. In addition to the overall dimensions, it is also necessary to check the air volume and static pressure, coil performance, filtration configuration and maintenance space. The replacement plan cannot be determined based only on the shell size.
Side extraction or other replacement methods can be determined during the design stage, and corresponding operating space can be reserved. Aili Industrial can simultaneously check filter specifications to facilitate subsequent matching of spare parts and consumables.
The horizontal air conditioning box needs to match the on-site space, air duct system, cold and heat sources and control requirements. Clarifying the air volume and static pressure, air treatment targets, interface locations and maintenance conditions in advance will help reduce installation adjustments and repeated selections.
Contact Aili Industrial immediately to obtain product information and configuration support for horizontal air conditioning boxes.
→ Submit size requirements for horizontal air conditioning boxes → Consult air volume, static pressure and filtration configuration
→ Communicate about original equipment replacement and interface adaptation → Understand non-standard customization and batch project matching
Aili Industry - From motors, fans and filters to sheet metal, control and complete machine assembly, it provides collaborative manufacturing and technical support for horizontal air treatment equipment.