Aili industrial three-door air shower adopts the structure of three doorways and is used for clean entrances that require multi-directional traffic or separate route management. The equipment can determine the location of entrances, exits and auxiliary passages based on the site layout, and configure door interlocks, shower procedures and access permissions in conjunction with the personnel flow process. The focus of selection is to clarify the areas connected by each door and the routes allowed to pass, so that the door position, control logic and clean management requirements match.
Status:
Quantity:

Aili industrial three-door air shower room

Configure clean entrances for multi-directional traffic

The entrance of some clean workshops needs to be connected to the changing area, clean operating area or other designated passages. The conventional straight-through double-door structure may be difficult to adapt to the on-site layout. The three-door air shower provides structural configuration space for traffic routes in different directions by adding a doorway.

The three-door structure does not mean that the three doors can be opened at the same time, nor does it mean that areas with different cleanliness levels can be directly shared. When designing, it is necessary to clarify the areas connected by each door, the direction of personnel passage, and the conditions for allowing opening, and then determine the corresponding interlocking and blowing procedures.

site conditions

layout concerns

Information required

Plan verification direction

Between the changing area and clean area

Door position and area connection

Floor plan and personnel traveling direction

Determine the purpose of the three doors

Multi-directional personnel access

Access routes and interlocks

The connecting areas and allowed routes of each door

Check gating logic

Non-standard entrance renovation

Existing partition walls and door openings

Door opening size and finished surface location

Coordinated installation interface

Connecting different management areas

Blowing and permission control

Cleanliness and management requirements for each area

Confirm control plan

What is the difference between a three-door air shower and a corner air shower?

Compare items

Three-door air shower

Corner air shower room

Door configuration

Set up three doorways and define the purpose of each door according to the project

Diversion is usually achieved through two doorways

Design focus

Multi-route access, door interlocking and authority control

The entry and exit directions match the on-site corner space

control requirements

It is necessary to clarify the opening conditions between different doors

Set up control procedures around designated entry and exit routes

Selection basis

Regional connection relationships, allowed routes and personnel management

Channel direction, installation space and personnel passage

The number of doors is a structural condition, and the access route and gate control logic determine how the equipment is used. Please refer to the door position relationship of the corner air shower room. Corner air shower room to understand.

Features

Features

Specific instructions

Door positions are configured according to layout

Determine the layout direction of the three doorways based on the location of adjacent areas and personnel movement lines.

Access routes can be defined

Clearly allow entry and exit combinations and one-way and two-way traffic methods according to project requirements.

Configurable door interlocks

Combine door status detection with lock control logic to manage the door opening sequence during normal operation.

The shower program is set according to the route

Distinguish entry routes that require showering from other permitted routes to reduce confusion in operational procedures.

Structure and airflow co-designed

The doorway will take up wall space, and the layout of the nozzles, return air vents and air ducts needs to be checked at the same time.

Support non-standard sizes

Determine equipment specifications based on the number of users, door opening size, on-site space and maintenance conditions.

The basic structure of the air shower room can be viewed Air showers understand different models.

Working principle and general process

Personnel enter the air shower area through the permitted entrance and close the entrance door. After the equipment confirms that the status of the relevant door meets the set conditions, it starts the fan and blows the filtered air through the nozzle to the surface of the clean clothes to help reduce some loose and attached particles.

After the shower is completed, the equipment releases the corresponding exit according to the selected traffic route, and personnel enter the designated area.

Allow the entrance to open → allow personnel to enter and close the door → confirm door status → purge operation → release corresponding exit

Route settings vary from project to project. It cannot be assumed that any two doors are passable just based on the three-door structure. The purpose and action sequence of each door should be clearly defined in the technical plan. For multi-person access configuration, please refer to Double double hair shower room and Triple-double air shower room to understand.

Three-door interlocking and traffic management

Control items

Configure concerns

Door status detection

Confirm whether each door is closed and use it as a judgment condition for shower and door opening control.

door interlock

Set the doors that are allowed to be opened according to the traffic route, and manage the simultaneous opening of doors.

Route selection

Set buttons, permissions, or external signals to select access routes as needed for the project.

Blower control

Clarify which routes require blowing and showering, as well as the exit release conditions after the blowing and showering.

Status prompt

Prompt running, waiting and abnormal status through display or indicating device.

Exception handling

Clarify how to deal with power outages, doors that are not fully closed, or equipment failures.

Normal operation interlocking, abnormal unlocking and on-site emergency requirements need to be confirmed together to avoid setting only the door lock function without complete operating logic. Please refer to the door form Learn about automatic sliding door air showers .

Filtration system and blowing structure

After the door is added to the three-door air shower, the wall area available for installing nozzles and return air outlets changes. Therefore, you cannot just add a door to the ordinary air shower box, but also need to recheck the air duct, nozzle position and maintenance space.

Aili Industrial can configure high-efficiency air filters based on the equipment structure, and match the filter specifications, resistance, installation sealing and fan working conditions. Filter products available HEPA and ULPA filters , confirm specifications in conjunction with particle control requirements. Please refer to the air volume conversion How to convert face wind speed and air volume? learn.

components

Function and design requirements

cabinet

Determine the structure based on the door position, passage space and on-site interfaces.

Fans and motors

Provides power for blowing and showering, combined with filter and air duct resistance options.

air filter

Filter circulating air, specifications and grades are confirmed according to design requirements.

blow shower nozzle

Arrange it reasonably on the available wall surface, and check the standing position and shower direction of personnel.

Return air structure

Maintain the return air path to avoid obvious obstruction by doors or personnel positions.

Door body and lock control

It is matched with the traffic route, door status detection and control program.

control system

Manage shower, door interlocking, route selection and status prompts.

Application scenarios

Electronic manufacturing clean entrance

Precision instrument assembly area

Medical device production entrance

Laboratory clean area entrance

Multi-directional personnel access

The connection between the dressing area and the work area

Non-standard clean entrance renovation

Access areas that need to be managed by route

When different cleanliness levels or different management areas are involved, you should first evaluate whether the shared shower space is suitable, and then determine the door position and route.

Matched with clean area air supply equipment

The air shower room is responsible for the surface blowing of people at the entrance. The internal environment of the clean area also needs to be maintained through air supply filtration, air flow organization, pressure difference and daily management.

Ai Li Industrial can be combined with FFU clean air supply products are equipped with clean area air supply. For local air supply needs inside production equipment or designated process locations, you can learn about it EFU equipment side fan filter unit . The logic of division of labor between the two lies in The division of labor between device-side EFU and room FFU is explained in detail.

Entrance equipment, room air supply and equipment end air supply should be selected according to their respective tasks to form a clean equipment configuration that matches the production process. When it comes to the overall clean room plan, you can refer to Should a new clean room project be graded or equipped first? and What should be checked first when upgrading the cleanliness of an old workshop? Understand the decision-making sequence.

Key points for selecting a three-door air shower room

Selection items

What needs to be clarified

regional connection

What areas are connected to each door, and what are the cleaning and management requirements for each area.

allowed route

Which doors allow traffic between them and whether there are one-way restrictions.

Blowing requirements

Which traffic routes must be showered, and how to control other routes.

Number of users

Number of people entering at a time, concentrated traffic periods and waiting space.

Door position and opening

The direction of the door opening, the opening range of the door leaf and whether there is any interference with adjacent passages.

Control permissions

Whether access control, route selection or external system linkage is required.

maintenance space

Access locations for filters, fans, lock controls and electrical components.

Field interface

Installation dimensions, power supply, ground height difference and surrounding enclosure structure.

For a three-door air shower, area connections and traffic rules should be determined first, and then the box size and control configuration should be determined. Insufficient maintenance channels will increase subsequent expenditures. This is reflected in what later expenses will be increased due to insufficient maintenance channels . There is a more detailed analysis of

Routine maintenance

Clean the inner wall, nozzles and return air outlets of the air shower in accordance with management requirements to avoid dust accumulation that affects the shower effect. The door movable area and return air outlet should not be blocked for a long time.

Regularly check the door interlocking, sensing device, lock control and shower timing functions. Maintain the primary filter according to the frequency of use, and determine the maintenance needs of the high-efficiency filter based on pressure difference, wind speed and filter status. After replacement, the installation seal and related performance should be rechecked. To judge the initial resistance and final resistance, please refer to What are the initial resistance and final resistance used to judge? , sealing inspection can refer to What should be checked when cleaning equipment is accepted?。

Aili Industrial's manufacturing and supporting capabilities

Aili Industrial has a production base of approximately 30,000 square meters, and its manufacturing system covers motors, fans, control systems, sheet metal processing, air filters, complete machine assembly and product testing.

For the three-door air shower room, Aili Industrial can check the door structure, shower system, filtration configuration and control program in the same plan to provide support for non-standard layout, on-site interface and project support. Through collaborative design of structure and control, the equipment configuration matches the actual personnel movement.

manufacturing link

Project support

Motors and fans

Match the shower air volume, filter resistance and operating requirements

air filter

Check efficiency, size and installation seals

control system

Configure door interlocking, route selection, shower timing and access control linkage

Sheet Metal and Structure

Realize three-door layout, cabinet size and installation interface

Complete machine assembly and testing

Organize production and inspection according to confirmed drawings and technical requirements

FAQ

Can three doors of a three-door air shower be opened at the same time?

During normal operation, it should be controlled according to the set interlock logic, and simultaneous door opening cannot be used as the default mode of use. Specific opening conditions are determined based on regional connection and access requirements.

Can a three-door air shower be equipped with one entrance and two exits?

It can be designed according to this route requirement, but it needs to be confirmed whether the two exit connection areas are suitable for sharing the shower space, and the exit selection and authority control methods must be clarified.

Can a three-door air shower connect areas with different cleanliness levels?

You cannot judge based on the number of doors alone. Shared spaces, pressure differential relationships, personnel routes and risks of contamination introduction need to be evaluated before determining whether to adopt this structure. Related concepts can be referred to What is the difference between cleanliness level and filtration efficiency?。

Can it be linked with the access control system?

Can be configured according to project requirements. It is necessary to confirm the access control authority, signal interface, route selection and processing logic in abnormal conditions. Door body linkage can be referred to Learn about automatic sliding door air showers .

Is the blowing effect of a three-door air shower the same as that of a two-door air shower?

You cannot judge based on the number of doors alone. The actual effect is related to the nozzle layout, fan operating conditions, personnel positions, blowing time and clean clothing status, and needs to be verified with specific equipment. For multi-person access configuration, please refer to Double double hair shower room and Triple-double air shower room to understand.

Can the size of the three-door air shower be customized?

It can be designed according to the door position, number of people, on-site installation space and maintenance requirements. When adjusting the size, it is also necessary to check the air duct, filter and nozzle configuration simultaneously.

Three-door air shower room selection and technical consultation

The three-door air shower needs to determine the personnel movement line, area division, door position and control logic. Clarifying the connection areas, allowed access routes and shower requirements of each door in advance will help reduce subsequent door position adjustments and program modifications.

Contact us to obtain product information and configuration plans for the three-door air shower.

→ Consult the three-door layout and personnel access plan → Submit door location and on-site installation dimensions
→ Understand door interlocking and access control linkage → Get customization support for non-standard air shower rooms

pass Aili Industrial Technology Consulting , communicates product selection and equipment matching needs.

Aili Industry - From core components to complete machines, we provide air shower equipment and project supporting support for the entrance of clean workshops.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.