Constant temperature and humidity purification air conditioning unit

Aili industrial constant temperature and humidity purification air conditioning units are designed for production and testing environments that require temperature and humidity adjustment and air filtration. They can combine air treatment functions according to the design working conditions, and coordinate fans, filters, boxes and control systems. The specific control range and accuracy are confirmed based on the project load, cold and heat sources, air flow organization and operating conditions.
Status:
Quantity:

Constant temperature and humidity purification air conditioning unit

Combining temperature and humidity treatment, air filtration and air supply control to provide supporting facilities for production and testing environments.

Aili industrial constant temperature and humidity purification air conditioning units are designed for applications that require temperature, humidity adjustment and air filtration. Functional units such as cooling and dehumidification, heating and reheating, humidification, filtration and air supply can be configured according to design requirements.

The unit configuration needs to be determined based on outdoor air conditions, fresh return air ratio, indoor sensible heat and moisture load, target environmental parameters and cold and heat source conditions. Aili Industry relies on motors, fans, filters, control systems, sheet metal and complete machine assembly capabilities to jointly check air treatment functions and component configurations to support project selection and non-standard customization.

→ Temperature and humidity requirements are jointly calculated → Air treatment functions are combined according to working conditions
→ Filtration and air supply are coordinated and matched → Control logic is configured according to projects

The appearance of AILIGY industrial constant temperature and humidity purification air-conditioning unit is a white box with an orange frame, equipped with an access door, observation window and control panel.

Determine treatment plans around temperature and humidity targets

'Constant temperature and humidity' requires clear target range, allowed fluctuations, measurement locations and verification conditions. Product selection should consider both the design load and partial load conditions to match the processing capacity, adjustment method and site conditions.

Requirements

What needs to be confirmed

temperature target

Setting range, allowable fluctuation and measurement position

Humidity target

Relative humidity, moisture content or dew point requirements

Operating conditions

Year-round operating hours and seasonal changes

Indoor load

Heat, cold and moisture loads from equipment, personnel, building envelopes and processes

New return air conditions

Fresh air volume, return air status and exhaust and supplementary air requirements

Verification requirements

Test conditions, stabilization time, sampling location and recording method

Function configuration

Function module

Main function

Configuration basis

air filtration

Hierarchical filtering based on system requirements

Air source, filtration division and terminal requirements

Cooling and dehumidification

Cools air and reduces moisture content to design conditions

Inlet air conditions, cooling sources and humidity targets

Heat and reheat

Increase the temperature or adjust the air supply status after dehumidification

Heat source conditions and processing procedures

humidify

Replenish air humidity when needed

Winter working conditions, humidification amount and water vapor conditions

Fan air supply

Deliver treated air

Air volume, internal resistance and external static pressure

Control monitoring

Coordinate sensors, valves, fans and processing units

Measuring points, adjustment methods and linkage requirements

Each functional module is selected by project. This type of unit can adopt different cold and heat source forms. The system configurations of chilled water type and direct expansion type are different and need to be selected separately.

Aili Industrial's manufacturing and technological advantages

The control system is independently developed to coordinate temperature and humidity adjustment.

Aili Industrial has the ability to develop control system software and hardware, and can communicate temperature and humidity measurement points, adjustment logic, operating modes and alarm functions according to project requirements.

For the cooperation between cooling, heating, reheating and humidification, the control sequence, execution components and linkage conditions can be clarified in the planning stage, and parameters can be confirmed in combination with on-site debugging.

Motors and fans work together to match different operating needs

Relying on its motor manufacturing and independent fan R&D and production capabilities, Aili Industrial can determine the configuration based on air volume, internal resistance, external static pressure and speed regulation requirements.

For projects that run for a long time or have load changes, the fan adjustment range, low-load operation, and the impact of changes in filter resistance on air supply can be checked simultaneously.

The filter and the whole machine are designed together

Aili Industrial has the ability to manufacture air filters, and can jointly confirm the filtration level, rated air volume, resistance, installation sealing and replacement space with the complete machine structure.

Synchronous checking of filtration configuration and temperature and humidity treatment configuration helps reduce the problem of mismatch between filter selection and fan and cabinet, and facilitates subsequent matching of consumables.

Independent processing of sheet metal, supporting interface and structure customization

Relying on sheet metal processing and complete machine assembly capabilities, the structure can be determined based on functional sections, thermal insulation, water connection and drainage, air outlets and maintenance requirements.

For projects with limited machine room size, transportation channels or takeover locations, the box segmentation, interface direction and maintenance space can be checked through drawings, and non-standard customization is supported.

Suzhou and Guangde collaborate to support batch delivery of projects

Aili Industrial can coordinate technology selection, control development, component production, sheet metal processing, assembly and inspection. Multiple equipment projects can uniformly check configurations, interface directions and spare parts specifications to facilitate installation, maintenance and management.

Purification configuration and temperature and humidity configuration should be considered simultaneously

Temperature and humidity regulation and particle filtration are different tasks and should be designed together according to project requirements.

attention direction

Supporting content

Temperature and humidity treatment

Heat and cold sources, processing loads, coils, humidification and control

air filtration

Filtration level, rated air volume, resistance and sealing

airflow organization

Air supply and return position, terminal form and area coverage

Installation and maintenance

Box insulation, drainage, maintenance and filter replacement

When used in clean rooms, the cleanliness level must be achieved by air treatment, terminal filtration, air flow organization, enclosure structure and operation management, and must be confirmed through system debugging and testing.

Product parameters and customization scope

Parameter items

Configuration instructions

Parameter items

Configuration instructions

Design air volume

Determined according to load and system air supply requirements

External static pressure

Determine based on external air path resistance

Temperature setting range

Confirm by project goals

Humidity setting range

Confirm based on project goals and processing capabilities

Control accuracy

Confirm according to agreed working conditions and verification methods

New return air ratio

Determined by system design

Hot and cold processing capabilities

Calculated according to design conditions

Humidification and dehumidification

Configured according to moisture load and air condition

Filter configuration

Select according to system requirements

Fans and motors

Match according to working point and speed regulation requirements

Hot and cold source form

Determined by project availability

Cabinet size

Determine according to functional segment and installation space

Drainage and insulation

Designed according to operating conditions

control interface

Determined according to project monitoring and linkage requirements

The specific temperature and humidity range, control accuracy, power, cooling and heat quantity, noise and size are subject to the confirmed technical data.

Applicable scenarios

Application scenarios

main focus

Precision electronic manufacturing

Temperature and humidity adjustment, filtration configuration and operational stability

Optical and precision instrument production

Ambient temperature and humidity, air flow coverage and load changes

Detection and measurement area

Measuring point layout, allowable fluctuations and verification conditions

Medical devices and related production areas

Temperature and humidity treatment, filtration division of labor and maintenance requirements

Clean workshop renovation

Compatibility of original cold and heat sources, air ducts and control systems

Related product packages

HEPA/ULPA air filters
determine efficiency level, air volume, resistance and sealing structure based on the filtering position of the system.

The FFU fan filter unit
is used for circulating filtered air supply in the corresponding clean area, and needs to coordinate the air volume and operation tasks with the air conditioning unit.

The high-efficiency air supply outlet
is suitable for duct-type end filter air supply, and is matched according to the single outlet air volume, quantity and installation conditions.

FAQ

How high control accuracy can the constant temperature and humidity unit achieve?

It needs to be evaluated in combination with project objectives, equipment adjustment capabilities, cold and heat source stability, load changes, airflow organization and sensor layout. The accuracy and verification conditions should be specified in the technical plan.

Does the constant temperature and humidity purification air conditioning unit have its own cold and heat sources?

uncertain. The cold water type requires an external cold and heat source; the direct expansion type requires a corresponding refrigeration system, and the specific scope of supply should be specified in the plan.

Why do some dehumidification solutions require reheating?

After cooling and dehumidification, the air temperature may be lower than the target supply air temperature. At this time, it can be adjusted by reheating. Whether reheating is required should be calculated based on the air treatment process.

Can the unit reach the cleanliness level after installing the filter?

You cannot tell based on filter configuration alone. It also needs to be confirmed through system debugging and testing based on the terminal equipment, air supply volume, air flow organization and on-site conditions.

Can Aili Industrial match the existing control system interface?

Interface and control requirements can be provided for evaluation, including start and stop, alarm, operating status and communication requirements. Specific protocols and functions will be confirmed during the planning stage.

What information is required for non-standard selection?

It is recommended to provide temperature and humidity targets and allowable fluctuations, service area, load data, new return air volume, cold and heat source parameters, filtration requirements, installation dimensions and operation period.

Constant temperature and humidity purification air conditioning unit selection and technical consultation

Clarifying temperature and humidity targets, load changes, cold and heat source conditions, filtration requirements and verification methods will help determine equipment processing capabilities, adjustment methods and structural configurations.

Contact Aili Industrial immediately to obtain product information and selection support for constant temperature and humidity purification air conditioning units.

→ Submit temperature and humidity targets and working conditions → Consult filtration and hot and cold treatment configurations
→ Communicate control functions and system interfaces → Understand non-standard customization and batch matching

Aili Industry - From motors, fans and filters to sheet metal, control and complete machine assembly, it provides collaborative manufacturing and technical support for constant temperature and humidity purified air treatment projects.

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.