Combining temperature and humidity treatment, air filtration and air supply control to provide supporting facilities for production and testing environments.
Aili industrial constant temperature and humidity purification air conditioning units are designed for applications that require temperature, humidity adjustment and air filtration. Functional units such as cooling and dehumidification, heating and reheating, humidification, filtration and air supply can be configured according to design requirements.
The unit configuration needs to be determined based on outdoor air conditions, fresh return air ratio, indoor sensible heat and moisture load, target environmental parameters and cold and heat source conditions. Aili Industry relies on motors, fans, filters, control systems, sheet metal and complete machine assembly capabilities to jointly check air treatment functions and component configurations to support project selection and non-standard customization.
→ Temperature and humidity requirements are jointly calculated → Air treatment functions are combined according to working conditions
→ Filtration and air supply are coordinated and matched → Control logic is configured according to projects
'Constant temperature and humidity' requires clear target range, allowed fluctuations, measurement locations and verification conditions. Product selection should consider both the design load and partial load conditions to match the processing capacity, adjustment method and site conditions.
Requirements |
What needs to be confirmed |
|---|---|
temperature target |
Setting range, allowable fluctuation and measurement position |
Humidity target |
Relative humidity, moisture content or dew point requirements |
Operating conditions |
Year-round operating hours and seasonal changes |
Indoor load |
Heat, cold and moisture loads from equipment, personnel, building envelopes and processes |
New return air conditions |
Fresh air volume, return air status and exhaust and supplementary air requirements |
Verification requirements |
Test conditions, stabilization time, sampling location and recording method |
Function module |
Main function |
Configuration basis |
|---|---|---|
air filtration |
Hierarchical filtering based on system requirements |
Air source, filtration division and terminal requirements |
Cooling and dehumidification |
Cools air and reduces moisture content to design conditions |
Inlet air conditions, cooling sources and humidity targets |
Heat and reheat |
Increase the temperature or adjust the air supply status after dehumidification |
Heat source conditions and processing procedures |
humidify |
Replenish air humidity when needed |
Winter working conditions, humidification amount and water vapor conditions |
Fan air supply |
Deliver treated air |
Air volume, internal resistance and external static pressure |
Control monitoring |
Coordinate sensors, valves, fans and processing units |
Measuring points, adjustment methods and linkage requirements |
Each functional module is selected by project. This type of unit can adopt different cold and heat source forms. The system configurations of chilled water type and direct expansion type are different and need to be selected separately.
Aili Industrial has the ability to develop control system software and hardware, and can communicate temperature and humidity measurement points, adjustment logic, operating modes and alarm functions according to project requirements.
For the cooperation between cooling, heating, reheating and humidification, the control sequence, execution components and linkage conditions can be clarified in the planning stage, and parameters can be confirmed in combination with on-site debugging.
Relying on its motor manufacturing and independent fan R&D and production capabilities, Aili Industrial can determine the configuration based on air volume, internal resistance, external static pressure and speed regulation requirements.
For projects that run for a long time or have load changes, the fan adjustment range, low-load operation, and the impact of changes in filter resistance on air supply can be checked simultaneously.
Aili Industrial has the ability to manufacture air filters, and can jointly confirm the filtration level, rated air volume, resistance, installation sealing and replacement space with the complete machine structure.
Synchronous checking of filtration configuration and temperature and humidity treatment configuration helps reduce the problem of mismatch between filter selection and fan and cabinet, and facilitates subsequent matching of consumables.
Relying on sheet metal processing and complete machine assembly capabilities, the structure can be determined based on functional sections, thermal insulation, water connection and drainage, air outlets and maintenance requirements.
For projects with limited machine room size, transportation channels or takeover locations, the box segmentation, interface direction and maintenance space can be checked through drawings, and non-standard customization is supported.
Aili Industrial can coordinate technology selection, control development, component production, sheet metal processing, assembly and inspection. Multiple equipment projects can uniformly check configurations, interface directions and spare parts specifications to facilitate installation, maintenance and management.
Temperature and humidity regulation and particle filtration are different tasks and should be designed together according to project requirements.
attention direction |
Supporting content |
|---|---|
Temperature and humidity treatment |
Heat and cold sources, processing loads, coils, humidification and control |
air filtration |
Filtration level, rated air volume, resistance and sealing |
airflow organization |
Air supply and return position, terminal form and area coverage |
Installation and maintenance |
Box insulation, drainage, maintenance and filter replacement |
When used in clean rooms, the cleanliness level must be achieved by air treatment, terminal filtration, air flow organization, enclosure structure and operation management, and must be confirmed through system debugging and testing.
Parameter items |
Configuration instructions |
Parameter items |
Configuration instructions |
|---|---|---|---|
Design air volume |
Determined according to load and system air supply requirements |
External static pressure |
Determine based on external air path resistance |
Temperature setting range |
Confirm by project goals |
Humidity setting range |
Confirm based on project goals and processing capabilities |
Control accuracy |
Confirm according to agreed working conditions and verification methods |
New return air ratio |
Determined by system design |
Hot and cold processing capabilities |
Calculated according to design conditions |
Humidification and dehumidification |
Configured according to moisture load and air condition |
Filter configuration |
Select according to system requirements |
Fans and motors |
Match according to working point and speed regulation requirements |
Hot and cold source form |
Determined by project availability |
Cabinet size |
Determine according to functional segment and installation space |
Drainage and insulation |
Designed according to operating conditions |
control interface |
Determined according to project monitoring and linkage requirements |
The specific temperature and humidity range, control accuracy, power, cooling and heat quantity, noise and size are subject to the confirmed technical data.
Application scenarios |
main focus |
|---|---|
Precision electronic manufacturing |
Temperature and humidity adjustment, filtration configuration and operational stability |
Optical and precision instrument production |
Ambient temperature and humidity, air flow coverage and load changes |
Detection and measurement area |
Measuring point layout, allowable fluctuations and verification conditions |
Medical devices and related production areas |
Temperature and humidity treatment, filtration division of labor and maintenance requirements |
Clean workshop renovation |
Compatibility of original cold and heat sources, air ducts and control systems |
HEPA/ULPA air filters
determine efficiency level, air volume, resistance and sealing structure based on the filtering position of the system.
The FFU fan filter unit
is used for circulating filtered air supply in the corresponding clean area, and needs to coordinate the air volume and operation tasks with the air conditioning unit.
The high-efficiency air supply outlet
is suitable for duct-type end filter air supply, and is matched according to the single outlet air volume, quantity and installation conditions.
It needs to be evaluated in combination with project objectives, equipment adjustment capabilities, cold and heat source stability, load changes, airflow organization and sensor layout. The accuracy and verification conditions should be specified in the technical plan.
uncertain. The cold water type requires an external cold and heat source; the direct expansion type requires a corresponding refrigeration system, and the specific scope of supply should be specified in the plan.
After cooling and dehumidification, the air temperature may be lower than the target supply air temperature. At this time, it can be adjusted by reheating. Whether reheating is required should be calculated based on the air treatment process.
You cannot tell based on filter configuration alone. It also needs to be confirmed through system debugging and testing based on the terminal equipment, air supply volume, air flow organization and on-site conditions.
Interface and control requirements can be provided for evaluation, including start and stop, alarm, operating status and communication requirements. Specific protocols and functions will be confirmed during the planning stage.
It is recommended to provide temperature and humidity targets and allowable fluctuations, service area, load data, new return air volume, cold and heat source parameters, filtration requirements, installation dimensions and operation period.
Clarifying temperature and humidity targets, load changes, cold and heat source conditions, filtration requirements and verification methods will help determine equipment processing capabilities, adjustment methods and structural configurations.
Contact Aili Industrial immediately to obtain product information and selection support for constant temperature and humidity purification air conditioning units.
→ Submit temperature and humidity targets and working conditions → Consult filtration and hot and cold treatment configurations
→ Communicate control functions and system interfaces → Understand non-standard customization and batch matching