news

What manufacturing links does Aili's independent supporting capabilities for industrial air-conditioning boxes include?

Number of views: 8271     Author: AILI Industrial Release time: 2027-06-18 Source: Ai Li Industrial

Inquiry

['facebook','twitter','linkedin','pinterest','whatsapp']

What manufacturing links does Aili's independent supporting capabilities for industrial air-conditioning boxes include?

The independent supporting links introduced on the official website of Aili Industry cover motors and fans, control systems, air filters, sheet metal and complete machines. For air-conditioning box projects, the value of these links is to facilitate joint checking of interfaces and configurations; whether they are suitable for a certain project should still be implemented in specific drawings, components and technical documents.

Convert manufacturing links into verifiable project items

The fan and motor need to be matched under the same working conditions, the control system needs to adapt to the actual signal, the filter needs to be connected to the installation frame, airflow and maintenance space, and the sheet metal needs to put the components into a structure that can be installed and serviced. Independent matching does not mean that all external energy and engineering work are included in the supply and should be confirmed item by item.

The fan motor needs to check the performance conditions, drive and installation interface; the filtration control needs to check the filter material installation, resistance, point table and linkage requirements; the structural machine needs to check the size, segmentation, connection and maintenance conditions. The three types of matters correspond to different majors, and the suitability of the project cannot be judged solely by the words 'independent manufacturing'. What project information should be prepared before selecting the air-conditioning box? Please refer toWhat project information should be prepared before selecting an air-conditioning box?。

Motor and fan links: matching around the actual working point

Aili Industrial has the capability of independent R&D and production of motors and fans, which can be matched based on the target air volume, internal resistance of the unit, external static pressure and speed regulation requirements. For the situation where the resistance increases after the filter is used, the fan adjustment range and operating margin can be checked during the selection stage to reduce the configuration deviation caused by selecting based only on the rated air volume.

Why should the fan efficiency range be checked? Please refer toWhy should we check the efficiency range when selecting air-conditioning box fans? . For DC fan drive and signal matching, please refer toWhat driving conditions need to be matched when using a DC fan in an air-conditioning box? . How to establish the fan pressure budget, please refer toHow is the total pressure of the air conditioning box fan determined by the internal resistance and external demand?。

Control system link: confirm the operating logic and interface together

Aili Industrial has the ability to develop control system software and hardware, and can communicate fan start and stop, speed regulation, temperature and humidity adjustment, filter pressure difference prompts and external equipment linkage according to project requirements. Specific sensors, actuators, communication protocols and interface forms are confirmed during the planning stage to facilitate connection with the project control system.

For control point table and signal definition, please refer toWhat point tables need to be provided before the air-conditioning box is connected to the building automation system? . The difference between BACnet interface and dry contact, please refer toWhat is the difference between the BACnet interface and dry contact linkage of the air conditioning box? . How to clarify the Modbus register information, please refer toWhat register information should be specified in Modbus communication of air conditioning box?。

Air filter link: The filter section and the installation frame are jointly confirmed

Aili Industrial has the ability to manufacture air filters and can confirm the filter size, filtration grade, head wind speed, initial resistance and installation method together with the air conditioning box structure. The filter section is not a single filter element. The frame sealing, compression method and extraction space will all affect the actual performance.

How to grade and configure the initial effect and medium effect, please refer toHow to configure the primary-efficiency and medium-efficiency filters of air-conditioning boxes in different stages? . How to select the filter level according to the inlet air conditions, please refer toHow to select the air conditioning box filter grade based on the inlet air conditions? . What should be considered when placing the filter section before and after the fan? Please refer toWhat needs to be considered when arranging the filter section before and after the fan?。

Sheet metal and complete machine assembly links: install and maintain conditions down to the structure

Relying on its sheet metal processing and complete machine assembly capabilities, Aili Industrial can adjust the box size, segmentation form, air outlet position and maintenance side according to the on-site space. When designing the structure, the filter extraction direction, fan maintenance space, coil cleaning and transportation conditions are simultaneously considered to make the equipment layout more suitable for on-site use needs.

How to choose between combined and integral types, please refer toHow to choose between combined and integrated air conditioning boxes? . How to mark the assembly sequence for segmented transportation, please refer toHow to identify the assembly sequence for segmented transportation of combined air-conditioning boxes? . Whether the length can be compressed when the on-site space is limited, please refer toCan the length of the horizontal air conditioning box be reduced when there is insufficient plane space?。

Independent matching does not mean that all external conditions are automatically established

Independent matching can reduce the missing interfaces between motors, fans, controls, filtration and boxes, but it cannot replace the verification of target gas performance, on-site water system, electrical matching and installation and commissioning. The project scope should still be itemized, distinguishing between equipment supply, field work and system verification.

How to list applicable standards in procurement technical documents, please refer toWhat applicable standards should be listed in the technical documents for purchasing air-conditioning boxes? . Equipment and verification boundaries for pharmaceutical projects, please refer toHow to define the boundaries of equipment and verification work in the air-conditioning box of pharmaceutical clean workshop? . What conditions should be locked first for non-standard customization? Please refer toWhat unchangeable conditions should be determined first for non-standard customization of air-conditioning boxes?。

Aili industrial supporting equipment

When submitting a project to Aili Industrial, you can use the same equipment number to summarize the fan, filtration, structure and control requirements, and check the drawings and delivery materials one by one, so that independent supporting capabilities can be implemented at the project interface. Product form can be viewedAir handling unit andFan box page; clean air supply package can be combinedFFU fan filter unit andEFU equipment end fan filter unit verification; terminal particle filtration can be combinedHEPA/ULPA filter confirmation; when it comes to gaseous pollution control, you can communicate separatelyChemical filter solution; multiple devices can be linked together to understandFFU computer group control system . Supporting method of The specific manufacturing scope, configuration and delivery content still need to be confirmed based on the corresponding technical documents and on-site working conditions. Actual results are subject to on-site leak detection and performance test results.

Submit project parameters:https://ailigy.com/contactus.html

Related questions and answers

Does independent matching mean that all components are produced by Aili Industrial?
The official website introduction covers motors, fans, control systems, air filters, sheet metal and complete machine assembly. The scope of supply of specific projects should still be confirmed item by item based on technical documents.

What is the actual value of independent supporting facilities to the project?
It is convenient to check the fan working point, filter section interface, control logic and box structure in the same set of data, reducing the omission of cross-manufacturer interfaces, but it cannot replace on-site verification.

What kind of manufacturing information can Aili Industrial provide?
Equipment drawings, configuration instructions, control interfaces and filter section information can be provided according to the agreed scope. The specific content needs to be confirmed based on the project contract and technical documents.

Related articles

  1. What project information should be prepared before selecting an air-conditioning box?

  2. Why should we check the efficiency range when selecting air-conditioning box fans?

  3. What point tables need to be provided before the air-conditioning box is connected to the building automation system?

  4. How to configure the primary-efficiency and medium-efficiency filters of air-conditioning boxes in different stages?

Key points for selection and acceptance inspection

Check items

Confirm key points

Check items

Confirm key points

fan motor

Performance conditions, drivers and installation interfaces

Filter control

Filter material installation, resistance, point table and linkage

Structure of the whole machine

Dimensions, sections, connections and maintenance conditions

supply boundary

Distinguish between equipment supply and on-site work

Data correspondence

The drawings and configuration instructions are consistent with the contract

On-site verification

Leak detection, performance testing and operation records

Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.