Aili industrial side air inlet high-efficiency air supply outlet is a high-efficiency filtering air supply equipment used at the end of the clean air system. The product sets the air duct connection port on the side of the air supply box, and the upstream air enters the box through the side air inlet, and then is filtered by a high-efficiency filter before being supplied to the clean area.
The product is suitable for clean room ceiling systems with side air duct connections. It can be configured according to filter size, design air volume, ceiling module and air duct specifications, and supports non-standard size customization.
| Status: | |
|---|---|
| Quantity: | |
1. What is a side-intake high-efficiency air supply outlet?
The side-intake high-efficiency air supply outlet is a high-efficiency filtering air supply equipment installed on the ceiling of a clean room or in a terminal air treatment system.
Its main structural feature is that the air inlet is set on the side of the air supply box, and the air duct is connected to the air supply box from the side.
After the air is processed by the clean air conditioning system, it enters the air supply box through the air duct, and enters the HEPA high-efficiency filter after being organized by the internal air flow. The filtered air enters the clean area through the air supply surface.
Clean air conditioning system → Air duct → Side air inlet → Static pressure box → HEPA filter → Clean room
Compared with the top air inlet structure, the side air inlet air supply outlet is more suitable for installation conditions where the air duct is connected from the side.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
The side air inlet high-efficiency air supply outlet mainly consists of the following structures:
Structural composition |
Main function |
Configuration method |
Selection basis |
|---|---|---|---|
Air supply box |
Carrying filters and related components |
Standard or customized |
Ceiling size, filter size |
Side air inlet |
Connect upstream air duct |
According to the air duct configuration |
Air duct specifications |
static pressure box |
Organize the air entering the box |
Configure according to product structure |
System air volume |
HEPA filter |
Highly efficient filtration of terminal air |
H13, H14, etc. optional |
Cleanliness level and project requirements |
Air supply side |
Send filtered air to clean areas |
According to product configuration |
Air supply method |
fixed structure |
Fixed box and filter |
Configure according to model |
ceiling structure |
The air inlet is set on the side of the air supply box, and the air duct can be connected from the side, which is suitable for the corresponding clean room air duct layout.
According to the ceiling structure and air duct direction, the side air inlet structure can be selected for terminal air supply equipment configuration.
Configure corresponding HEPA high-efficiency filters according to project requirements to perform terminal filtration of the air entering the clean area.
For projects where the air duct needs to be connected from the side of the air supply outlet, the side air inlet structure can be matched with the upstream air duct.
Product specifications can be configured based on filter size, design air volume and ceiling modules.
The box size, filter size, air inlet size and air inlet position can be customized according to the project installation conditions.
Both products can be used for terminal filtered air supply in clean air systems. The main difference lies in the direction of the air duct connection.
Compare items |
Side air inlet efficient air supply outlet |
Top-inlet high-efficiency air supply outlet |
|---|---|---|
Air inlet position |
Side of air supply box |
Top of air supply box |
Duct direction |
Connect from the side |
Connect from above |
head space |
Determine based on on-site conditions |
Top installation space needs to be considered |
side space |
Need to consider the air inlet interface space |
The side space is relatively independent |
Duct layout |
Suitable for side air ducts |
Suitable for top air ducts |
Common applications |
Clean rooms, laboratories, electronic manufacturing, etc. |
Clean rooms, laboratories, electronic manufacturing, etc. |
custom made |
support |
support |
The actual selection should be determined based on the clean room ceiling, air duct direction, installation height and on-site equipment layout.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
The air processed by the air conditioning system is transported through the air duct to the air inlet interface on the side of the air supply outlet.
After the air enters the air supply box, the airflow is organized inside the box, and then passes through the HEPA high-efficiency filter for terminal filtration. The filtered air enters the clean area through the air supply surface.
Air treatment → Duct transportation → Side air inlet → Static pressure box → HEPA filtration → Terminal air supply
The side air inlet high-efficiency air supply outlet is mainly responsible for terminal filtration and air supply functions.
The final air cleanliness of a clean room is also related to factors such as the air conditioning system, air supply volume, number of air changes, air flow organization, filter performance, indoor equipment and operation and maintenance.
The side air inlet high-efficiency air supply outlet can be equipped with corresponding high-efficiency filters according to the cleanliness requirements of the project.
Common configurations can include H13, H14, etc. The specific filter grade needs to be determined based on the clean room design parameters, design air volume and project requirements.
Configuration items |
Main considerations |
|---|---|
Filter level |
Clean room design requirements |
filter size |
Air supply volume and box size |
filter thickness |
Filter structure and system resistance |
Rated air volume |
System design air volume |
initial resistance |
Air conditioning system static pressure and fan capacity |
Sealing method |
Filter and box structure |
Replacement method |
Project maintenance plan |
The filter specifications should match the air supply box and system air volume.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Aili industrial side air inlet high-efficiency air supply vents can be configured according to different filter specifications and designed air volumes.
model |
Static plenum size (mm) |
Filter size (mm) |
Reference air volume (m³/h) |
Side air inlet |
|---|---|---|---|---|
AILIGY-320 |
370×370×530 |
320×320×320 |
500 |
200×200 |
AILIGY-484 |
534×534×530 |
484×484×220 |
1000 |
320×200 |
AILIGY-610 |
660×660×460 |
610×610×150 |
1000 |
320×250 |
AILIGY-630 |
680×680×530 |
630×630×220 |
1500 |
320×250 |
AILIGY-915 |
965×660×460 |
915×610×150 |
1500 |
500×250 |
AILIGY-1260 |
1310×680×530 |
1260×630×220 |
3000 |
600×250 |
Parameter description: The above are reference specifications. The actual product size, filter parameters, air inlet size and design air volume should be determined based on the final product configuration and project technical requirements.
The selection of high-efficiency side air supply outlets requires consideration of cleanliness, air volume, filters, ceiling size and side air duct conditions.
Cleanliness level → Design air volume → Filter specification → Ceiling size → Air supply outlet size → Side air inlet → Air duct connection
Determine the required air supply volume based on the clean room design parameters.
Select the filter grade, size and thickness according to the design air volume and cleanliness requirements.
Confirm the installation position of the air supply vent and the size of the ceiling module.
Confirm whether there is enough space on the side of the air supply box to connect the air duct.
Determine the size and connection method of the side air inlet according to the specifications of the upstream air duct.
Confirm the equipment space above the ceiling and the side air duct connection space.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
The side air inlet high-efficiency air supply outlet can be used in different clean environments according to the clean room system design.
Semiconductor manufacturing |
Electronic manufacturing |
Pharmaceutical production |
biology laboratory |
|---|---|---|---|
Clean workshop, clean production area |
Electronic product production environment |
Clean production area |
Laboratory clean environment |
Optical manufacturing |
Precision manufacturing |
medical related environment |
Clean room renovation |
|---|---|---|---|
Optical product production area |
Precision machining clean area |
Configure according to project air treatment requirements |
Renovation of the original clean system |
The specific application needs to be determined based on the project cleanliness level, design air volume and on-site installation conditions.
Clean environments such as semiconductor and electronic manufacturing need to configure terminal filtration and air supply equipment according to the clean room design requirements.
The side air inlet high-efficiency air supply outlet can be installed on the ceiling of the clean room and connected to the clean air duct through the side interface.
MAU/AHU → Clean air duct → Side air inlet HEPA air supply outlet → HEPA filtration → Clean room
For projects where the air duct is arranged from the side of the air supply outlet, product configuration can be made based on the position of the air duct, ceiling module and installation space.
Terminal air supply equipment in clean environments such as pharmaceuticals and laboratories needs to be configured based on the cleanliness level, design air volume and air treatment system.
The side air inlet high-efficiency air supply outlet can be equipped with a HEPA filter according to project requirements, and is connected to the clean air duct through the side air inlet interface.
It is recommended to confirm when selecting:
project |
What needs to be confirmed |
|---|---|
Cleanliness level |
ISO level or project requirements |
filter |
HEPA rating and size |
Air volume |
Design air volume |
suspended ceiling |
Module size |
air duct |
Side duct size |
Installation space |
Ceiling and side space |
quantity |
Room and system configuration |
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Clean room renovation projects usually require the use of original ceilings, air ducts and equipment installation spaces.
The side air inlet high-efficiency air supply outlet can be designed according to the lateral connection conditions of the original air duct.
It is recommended to confirm before modification:
Original air supply outlet→ Ceiling size→ Side air duct position→ Installation height→ Design air volume→ Filter size→ New air supply outlet specifications
If the original air supply outlet size, filter size or air duct interface is different from the standard specifications, non-standard design can be carried out according to site conditions.
Before installation, you need to confirm the size of the air supply outlet, filter specifications, position of the side air inlet, ceiling module and air duct connection method.
Basic installation process:
Confirm the installation position → Fix the air supply box → Connect the side air duct → Install the HEPA filter → Check the connections and seals → System debugging → Air volume detection
The specific installation method should be carried out in accordance with the product structure, on-site construction conditions and project installation drawings.
During the operation of the equipment, inspections need to be carried out based on the actual operating status of the clean room.
Check items |
Check content |
|---|---|
Filter pressure difference |
Observe changes in operating pressure difference |
Air supply volume |
Check the actual air volume of the system |
filter status |
Check contamination and usage status |
Duct connection |
Check side interface connections |
Cabinet status |
Check the box and fixed structure |
sealed state |
Check filter installation seal |
Air supply side |
Check surface cleanliness and integrity |
The filter replacement cycle should be determined based on the actual pressure difference, air volume, clean room test results and project maintenance system.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Aili Industrial can customize the side air inlet high-efficiency air supply vents according to the clean room's ceiling size, design air volume, filter specifications and air duct conditions.
Customized items |
Configurable content |
Main basis |
|---|---|---|
Cabinet size |
Length×width×height |
Ceiling and filter dimensions |
filter size |
According to project configuration |
Design air volume |
Side air inlet |
Dimensions and connection methods |
Air duct specifications |
Air inlet location |
Configure according to site conditions |
Duct layout |
Cabinet material |
According to project requirements |
Usage environment |
Air supply side |
Configure according to product structure |
Air supply requirements |
product specifications |
Standard or non-standard |
Installation space |
OEM |
Design according to customer requirements |
Project requirements |
ODM |
Product design according to technical requirements |
Project plan |
Aili Industrial is engaged in the R&D and manufacturing of purification equipment and clean air treatment products. Its products cover high-efficiency air outlets, HEPA BOX, HEPA high-efficiency filters, ULPA filters, FFU, EFU, BFU, fans, motors and control systems, etc.
The side air inlet high-efficiency air supply outlet can be configured by combining filters, air volume, ceiling size and side air duct specifications.
Aili Industry has a production plant of approximately 30,000 square meters, and has formed a production system for fans, motors, control systems, sheet metal structures, filters, purification equipment and other products, and can provide equipment matching according to clean room projects.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
If Aili Industrial needs to select products, it is recommended to provide the following parameters:
project |
Information required |
Selection effect |
|---|---|---|
Usage scenarios |
Clean room, laboratory, pharmaceutical, electronics, etc. |
Determine product application |
Cleanliness level |
ISO level or project requirements |
Determine filtering plan |
Design air volume |
m³/h |
Determine product specifications |
Filter level |
H13, H14, etc. |
Determine filtering configuration |
filter size |
Length×width×height |
Determine cabinet size |
Ceiling size |
length×width |
Determine installation specifications |
Installation height |
mm |
Confirm device space |
Side duct |
Size and location |
Determine the air inlet interface |
Product quantity |
tower |
Confirm project supply |
Installation method |
New construction or renovation |
Determine product structure |
Aili Industry can provide a variety of terminal purification equipment according to different clean room systems.
product |
main structure |
Typical applications |
|---|---|---|
Side air inlet efficient air supply outlet |
Side air intake, terminal HEPA filtration |
Clean room terminal air supply |
Top-inlet high-efficiency air supply outlet |
Top air intake, terminal HEPA filtration |
Top duct connection project |
Ordinary high-efficiency air supply vent |
Static pressure box + high efficiency filter |
Conventional clean air conditioning system |
Liquid tank sealed high-efficiency air supply port |
Liquid tank sealing structure |
Clean environment with requirements for sealing method |
Disposable high-efficiency air outlet |
Disposable terminal air supply design |
Temporary and partial renovation projects |
FFU |
Fan + filter integration |
Clean room ceiling air supply |
EFU |
Compact fan filter unit |
Clean environment inside the equipment and local areas |
BFU |
Fan filter unit |
Local cleaning and equipment matching |
Different products have different structures and usage methods, and should be selected according to the cleanliness level, air supply method, installation space and system design of the project.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━
The side-intake high-efficiency air supply outlet is a terminal high-efficiency filtration air supply device with the air duct connection port set on the side of the air supply box. The air enters the box from the side and passes through the HEPA filter before being sent to the clean area.
The main difference is where the ducts connect. The side air inlet is connected to the air duct from the side of the air supply box, and the top air inlet is connected to the air duct from the top of the air supply box.
HEPA filters and corresponding air volumes can be configured according to the clean room design requirements and used for terminal filtration and air supply of the clean air system.
It is usually necessary to configure corresponding high-efficiency filters according to the product structure, and the specific filter grade and specifications are determined according to project requirements.
It can be configured according to the product structure and project requirements, and the actual filter specifications and technical parameters shall prevail.
It is suitable for clean rooms, laboratories, electronic manufacturing, pharmaceuticals and other clean air processing environments that require air ducts to be connected from the side of the air supply box.
Can. The size, location and connection method of the air inlet can be designed according to the on-site air duct conditions.
Can. Box size, filter size, side air inlets and other structures can be customized according to project conditions.
Can. Renovation projects need to provide the original air supply vents, ceilings, air ducts, installation space and other parameters.
Can. Aili Industrial also provides HEPA, ULPA and other air filtration products, which can be matched with filters according to the specifications of the air supply outlet.
Aili industrial products cover multiple links in the clean air treatment system.
Fan → Motor → Control system → Air filter → HEPA/ULPA → FFU → EFU → BFU → HEPA BOX → High-efficiency air supply outlet → Clean room supporting equipment
For projects that require multiple purification equipment, product combinations can be made based on project design parameters.
For example:
Clean air conditioner → Air duct → Side air inlet high-efficiency air supply outlet → HEPA filter → Clean room
It can also be adopted according to the project design:
MAU/AHU → Clean air duct → FFU → HEPA/ULPA filtration → Clean room
The specific system form needs to be determined based on the clean room area, cleanliness level, design air volume, equipment layout and project design plan.
Aili Industrial not only provides side-intake high-efficiency air supply vents, but also HEPA high-efficiency filters, ULPA filters, FFU, EFU, BFU, HEPA BOX, fans, motors and control systems.
For projects that require multiple clean equipment, they can be matched according to the specifications and parameters of different equipment.
Aili Industry has the production capacity of fans, motors, control systems, sheet metal structures, filters and purification equipment. It can configure products according to project size, air volume, filter specifications and installation conditions.
Recommendations for new clean room projects include:
Clean room use → Cleanliness level → Design air volume → Filter level → Filter size → Ceiling size → Installation height → Side duct size → Product quantity
If it is a renovation project, we can also provide:
Original air outlet size → Original filter size → Air duct size → Ceiling photo → Side installation space → Original system air volume
This can more accurately determine the specifications of the side air inlet high-efficiency air supply vents.
Aili industrial side air inlet high-efficiency air supply vents adopt a side air inlet structure and are suitable for clean air systems that require air ducts to be connected from the side of the air supply box.
Products can be configured based on HEPA filter size, design air volume, ceiling module, air duct specifications and installation space.
Standard specifications cover different sizes and air volume requirements, while supporting non-standard sizes, OEM and ODM customization.
For clean room construction, renovation, laboratories, electronic manufacturing, pharmaceuticals and other clean air treatment projects, the cleanliness level, design air volume, filter specifications, ceiling dimensions and side air duct parameters can be provided to Aili Industrial, and engineers will match products according to project conditions.
Side air inlet → HEPA high-efficiency filtration → Clean air terminal air supply
Aili Industrial provides:
Side air inlet high-efficiency air supply outlet→ Top air inlet high-efficiency air supply outlet→ Liquid tank sealed high-efficiency air supply outlet→ Disposable high-efficiency air supply outlet→ HEPA BOX → HEPA high-efficiency filter→ FFU → EFU → BFU
Provide project parameters → Confirm filter specifications → Confirm design air volume → Confirm ceiling size → Confirm side air duct → Confirm product model → Obtain product configuration plan