Top-inlet high-efficiency air supply outlet

Aili industrial top-inlet high-efficiency air supply vent is a HEPA high-efficiency filtered air supply equipment used at the end of the clean air system. Compared with the side air inlet structure, the top air inlet design sets the air duct connection port at the top of the air supply box, which can be configured according to the clean room ceiling, air duct direction and installation space.

The product consists of a static pressure box, a high-efficiency filter, an air supply surface and an air inlet connection structure. It can be selected according to the project design air volume, filter specifications and ceiling modules.

Status:
Quantity:
Aili industrial top air inlet high-efficiency air supply outlet

1. What is a high-efficiency top air supply outlet?

The top-inlet high-efficiency air supply outlet is a high-efficiency filtering air supply equipment installed on the ceiling of a clean room or at the end of a clean air system.


Its main structural feature is that the air inlet is located at the top of the air supply box. The upstream air enters the static pressure box through the top air duct, is filtered by the HEPA high-efficiency filter, and is finally supplied to the clean area through the air supply.


Clean air conditioning system → air duct → top air inlet → static pressure box → HEPA filter → clean room


The top air inlet structure is suitable for clean room projects that require air ducts to be connected from above the suspended ceiling. The specifications can also be adjusted according to the on-site installation space and air duct layout.

2. Top-intake high-efficiency air supply outlet structure

The top-inlet high-efficiency air supply outlet mainly consists of the following structures:

Structural composition

Main function

Configuration method

Selection basis

Air supply box

Hosts filters and related components

Standard or customized

Ceiling size, filter size

Top air inlet

Connect upstream air duct

Square or round etc.

Air duct specifications

static pressure box

Organize the incoming air

Configure according to product structure

System air volume

HEPA filter

Highly efficient filtration of terminal air

H13, H14, etc. optional

Cleanliness level and project requirements

Air supply side

Send filtered air to clean areas

According to product configuration

Air supply method

fixed structure

Fixed box and filter

Configure according to model

ceiling structure

3. What are the characteristics of the top air intake structure?

Air ducts are connected from the top

The air inlet interface is set on the top, which is suitable for installation in clean rooms where the air duct is located above the suspended ceiling.

Suitable for ceiling installation

The air supply box is installed in the clean room ceiling area, and the bottom is used as the terminal air supply surface to facilitate matching with the clean room ceiling system.

Terminal HEPA filtration

Configure corresponding HEPA high-efficiency filters according to project requirements to perform terminal filtration of the air entering the clean area.

Convenient for air duct layout

The top air inlet method can be connected according to the clean room air duct layout, which can reduce the impact of side interfaces on the installation space in some projects.

Various size configurations

The box size, filter size, air inlet size and air supply module can be configured according to project parameters.

Support non-standard customization

For clean room renovation, special ceilings and non-standard installation spaces, product design can be carried out according to on-site dimensions.

4. What is the difference between top air inlet and side air inlet high-efficiency air supply vents?

The main difference between top air inlet and side air inlet is the connection position of the air duct。

Compare items

Top-inlet high-efficiency air supply outlet

Side air inlet efficient air supply outlet

Air inlet position

Top of air supply box

Side of air supply box

Duct direction

Connect from above

Connect from the side

Air duct above suspended ceiling

Suitable

Determine based on on-site conditions

Lateral installation space

Occupy less

Need to consider side interface space

Duct layout

Suitable for top air duct layout

Suitable for side air duct layout

Common applications

Clean rooms, laboratories, electronic manufacturing, etc.

Clean room and other terminal air supply systems

custom made

support

support

The actual choice mainly depends on the clean room ceiling structure, air duct direction, installation height and on-site space.

5. Working principle of top-inlet high-efficiency air supply outlet

The air processed by the air conditioning system is transported to the top of the air supply outlet through the clean air conditioning duct.

After the air enters the static pressure box, the airflow is organized, and then passes through the HEPA high-efficiency filter for terminal filtration. The filtered air enters the clean area through the air supply surface.

Air treatment → Duct transportation → Top air inlet → Static pressure box → HEPA filtration → Terminal air supply

The air supply outlet is mainly responsible for terminal filtration and air supply functions.

The final cleanliness of a clean room is also related to factors such as air conditioning system, air supply volume, air changes, air flow organization, filter performance, indoor equipment and maintenance management.

6. HEPA high efficiency filter configuration

The top-inlet high-efficiency air supply outlet can be equipped with high-efficiency filters of different specifications according to the design requirements of the clean room.

Common configurations can include H13, H14, etc. The specific level should be determined based on clean room cleanliness requirements, filter performance parameters and project design.

Filter configuration

Main considerations

Filter level

Clean room design requirements

filter size

Air supply volume and box size

filter thickness

Filter structure and resistance

Rated air volume

System design air volume

initial resistance

Air conditioning system static pressure and fan capacity

Sealing method

Filter structure and project requirements

Replacement method

Project maintenance plan

The filter cannot be selected based solely on the air supply outlet model, but should be matched based on the actual system parameters.

7. Product specifications of top-intake high-efficiency air supply vents

Aili industrial ceiling-intake high-efficiency air supply vents can be configured according to filter size, design air volume and ceiling modules.

It is recommended that the website parameter table adopt the following structure:

model

Static plenum size (mm)

Filter size (mm)

Reference air volume (m³/h)

Top air inlet

AILIGY-320

370×370×530

320×320×320

500

200×200

AILIGY-484

534×534×530

484×484×220

1000

320×200

AILIGY-610

660×660×460

610×610×150

1000

320×250

AILIGY-630

680×680×530

630×630×220

1500

320×250

AILIGY-915

965×660×460

915×610×150

1500

500×250

AILIGY-1260

1310×680×530

1260×630×220

3000

600×250

Note: The above model names adopt the AILIGY brand naming method. The specific box size, filter size, air inlet size and design air volume should be based on the final product drawings and project technical parameters. Non-standard sizes can be customized according to project requirements.

8. How to choose a high-efficiency top air supply outlet?

When selecting, you should not just look at the external dimensions of the air supply outlet, but also consider the clean room design air volume, filter specifications and ceiling space.

Cleanliness level → Design air volume → Filter specification → Ceiling size → Air supply outlet size → Top air inlet → Air duct connection

① Determine the cleanliness level

First confirm the required cleanliness level of the clean room and the project's requirements for terminal filters.

② Determine the design air volume

Determine the required air supply volume based on the clean room area, number of air changes and system design parameters.

③ Determine the filter

Determine HEPA filter specifications based on design air volume and cleanliness requirements.

④ Confirm the ceiling size

Confirm the installation location of the air supply vent and the size of the ceiling module.

⑤ Confirm the top air inlet

Determine the specifications of the top air inlet interface based on the size of the upstream air duct.

⑥ Confirm the installation height

Check the equipment space, air duct height and other pipelines above the suspended ceiling to ensure that the equipment can be installed normally.

9. Applicable scenarios for top-intake high-efficiency air supply vents

The top-inlet high-efficiency air supply outlet is suitable for the terminal filtered air supply of the clean air system and can be used in different clean environments according to project requirements.

Semiconductor manufacturing

Electronic manufacturing

Pharmaceutical production

biology laboratory

Clean workshop, clean production area

Electronic product production environment

Clean production area

Laboratory clean environment

Optical manufacturing

Precision manufacturing

medical related environment

Clean room renovation

Optical product production area

Precision machining clean area

Configure according to project air treatment requirements

Renovation of the original clean system

The actual application needs to be configured according to the project cleanliness level, air volume, filter specifications and installation conditions.

10. Semiconductor and electronic manufacturing applications

Semiconductor and electronics manufacturing clean environments often require filtration control of terminal air supply.

The top-inlet high-efficiency air supply outlet can be installed on the ceiling of the clean room and connected to the upstream air treatment system through the top air duct.

MAU/AHU → Clean air duct → Top air HEPA air supply outlet → Clean room

For projects with centralized layout of air ducts above the ceiling, product configuration can be made based on the equipment installation location, ceiling modules and air duct interfaces.

11. Pharmaceutical and laboratory applications

In clean environments such as pharmaceuticals and laboratories, the configuration of terminal air supply equipment usually needs to be combined with the cleanliness level, air treatment system and project design requirements.

The top-inlet high-efficiency air supply outlet can be configured according to the filter specifications and designed air volume, and serves as the terminal filtering air supply equipment of the clean air conditioning system.

In actual projects, you need to consider at the same time:

project

Main confirmation content

Cleanliness level

ISO level or project requirements

filter

HEPA rating and size

Air volume

Design air volume

suspended ceiling

Module size

air duct

Top duct size

Installation space

Height above suspended ceiling

quantity

Room and system configuration

12. Clean room renovation application

Cleanroom renovation projects usually require the addition or replacement of terminal air supply equipment under the original ceiling and air duct conditions.

The top air inlet structure can be configured according to the location of the top air duct on site.

It is recommended to confirm before modification:

Original air supply outlet→ Ceiling size→ Air duct location→ Installation height→ Design air volume→ Filter size→ New air supply outlet specifications

If the size of the original equipment is inconsistent with the standard product, non-standard design can be made based on the on-site size.

13. Installation of top-intake high-efficiency air supply vents

Before installation, you need to confirm the product size, filter specifications, top air inlet interface, ceiling module and air duct connection method.

Basic installation process:

Confirm the installation position → Fix the air supply box → Connect the top air duct → Install the HEPA filter → Check the seal → System debugging → Air volume detection

The specific installation method should be implemented in accordance with the product structure, on-site construction conditions and project installation drawings.

14. Maintenance of high-efficiency air supply vents for top air inlet

During the operation of the top-intake high-efficiency air supply outlet, inspection should be carried out based on the actual operation conditions of the clean room.

It is recommended to focus on:

Check items

Check content

Filter pressure difference

Observe changes in operating pressure difference

Air supply volume

Check the actual air volume of the system

filter status

Check filter contamination

Box connection

Check the air duct and box connections

sealed state

Check filter installation seal

Air supply side

Check surface cleanliness and integrity

The filter replacement time should not be judged based on a fixed time alone, but should be determined in combination with pressure difference, air volume, clean room test results and project maintenance systems.

15. Customization of top-intake high-efficiency air supply vents

Aili Industrial can customize the top-intake high-efficiency air supply outlet according to the project's filter specifications, ceiling size, design air volume and air duct interface.

Customizable items

Customized items

Configurable content

Main basis

Cabinet size

Length×width×height

Ceiling and filter dimensions

filter size

According to project configuration

Design air volume

Top air inlet

Square, round, etc.

Air duct specifications

Air inlet location

Configure according to product structure

Duct layout

Cabinet material

According to project requirements

Usage environment

Air supply side

Configure according to product structure

Air supply requirements

Product size

Standard or non-standard

Installation space

OEM

Design according to customer requirements

Project requirements

ODM

Product design according to technical requirements

Project plan

16. Aili Industrial Top Inlet High-efficiency Air Supply Inlet Manufacturing Capacity

Aili Industrial is engaged in the R&D and manufacturing of purification equipment and clean air treatment products. Its products cover high-efficiency air outlets, HEPA BOX, HEPA filters, FFU, EFU, BFU, fans, motors and control systems, etc.

The top-inlet high-efficiency air supply outlet can be configured based on the project's filter, air volume, ceiling size and air duct specifications.

Aili Industrial has a production plant of approximately 30,000 square meters, and has formed a production system from fans, motors, control systems, sheet metal structures to filters and purification equipment. It can provide equipment matching according to different clean room projects.

17. Selection information for high-efficiency top air supply vents

If Aili Industrial needs to select products, it is recommended to provide the following parameters:

project

Information required

effect

Usage scenarios

Clean room, laboratory, pharmaceutical, electronics, etc.

Determine product application

Cleanliness level

ISO level or project requirements

Determine filtering plan

Design air volume

m³/h

Determine product specifications

Filter level

H13, H14, etc.

Determine filtering configuration

filter size

Length×width×height

Determine cabinet size

Ceiling size

length×width

Determine installation specifications

Installation height

mm

Confirm device space

Top duct

Size and location

Determine the air inlet interface

Product quantity

tower

Confirm project supply

Installation method

New construction or renovation

Determine product structure

18. Top-intake high-efficiency air supply vents and other purification equipment of Aili Industrial

Aili Industry can provide a variety of purification equipment according to different air treatment methods in clean rooms.

product

main structure

Typical applications

Top-inlet high-efficiency air supply outlet

Top air intake, terminal HEPA filtration

Clean room terminal air supply

Ordinary high-efficiency air supply vent

Static pressure box + high efficiency filter

Conventional clean air conditioning system

Liquid tank sealed high-efficiency air supply port

Liquid tank sealing structure

Clean environment with requirements for sealing method

Disposable high-efficiency air outlet

Disposable terminal air supply design

Temporary and partial renovation projects

FFU

Fan + filter integration

Clean room ceiling air supply

EFU

Compact fan filter unit

Clean environment inside the equipment and local areas

BFU

Fan filter unit

Local cleaning and equipment matching

Different products have different structures and working methods. The selection should be based on the cleanliness level, air supply method, installation space and system design of the project.

19. Frequently Asked Questions about Top Inlet High-efficiency Air Supply Vent

What is a top-intake high-efficiency air supply vent?

The top-inlet high-efficiency air supply outlet is a terminal high-efficiency filtration air supply device with an air duct connection port on the top. The air enters from the top of the air supply box and is sent to the clean area after passing through the HEPA filter.

What is the difference between top air intake and side air intake?

The main difference is where the ducts connect. The top air inlet is connected to the air duct from the top of the air supply box, and the side air inlet is connected to the air duct from the side of the box.

Are top-intake high-efficiency air supply vents suitable for clean rooms?

HEPA filters and corresponding air volumes can be configured according to the clean room design requirements and used for terminal filtration and air supply of the clean air conditioning system.

Do top-inlet high-efficiency air supply vents need to be equipped with HEPA filters?

Products usually need to be equipped with corresponding high-efficiency filters according to project requirements, and the specific grades and specifications should be determined according to the clean room design parameters.

Can H13 and H14 filters be configured?

It can be configured according to the product structure and project requirements, and the actual filter specifications and technical parameters shall prevail.

What kind of ceiling is suitable for top air supply vent?

It is suitable for clean room ceiling systems that require air ducts to be connected from above the ceiling. The details need to be confirmed based on the ceiling module and installation height.

Can non-standard sizes be made?

Can. Box size, filter size, top air inlet and other structures can be customized according to project conditions.

Can the top air inlet be resized?

It can be configured according to the size of the upstream air duct. The specific interface size needs to be confirmed during the product design stage.

Can overhead high-efficiency air supply vents be used in retrofit projects?

Can. Renovation projects need to provide parameters such as the original ceiling, air ducts, installation space, and designed air volume for product matching.

Can Aili Industrial provide matching filters?

Can. Aili Industrial also produces HEPA, ULPA and other air filtration products, which can be matched with filters according to the specifications of the air supply outlet.

20. Aili Industrial Whole Industry Chain Purification Equipment Supporting System

Aili Industrial's products cover multiple aspects of the clean air treatment system.

Fan → Motor → Control system → Air filter → HEPA/ULPA → FFU → EFU → BFU → HEPA BOX → High-efficiency air supply outlet → Clean room supporting equipment

For clean room projects that require multiple purification equipment, product combinations can be made based on project parameters.

For example:

Clean air conditioner → Air duct → Top-inlet high-efficiency air supply outlet → HEPA filter → Clean room

It can also be adopted according to project requirements:

MAU/AHU → Air Duct → FFU → HEPA/ULPA Filtration → Clean Room

The specific system form should be determined based on the clean room area, cleanliness level, design air volume, equipment layout and project design plan.

21. Why choose Aili Industrial Top Inlet High-efficiency Air Supply Vent?

Aili Industrial not only provides top-intake high-efficiency air supply vents, but also has products such as HEPA high-efficiency filters, ULPA filters, FFU, EFU, BFU, HEPA BOX, fans, motors and control systems.

For clean room projects, matching can be carried out according to the parameter relationship between different products.

Aili Industrial uses self-developed fans, motors and control systems, and has the production capacity of sheet metal, filters and purification equipment. It can configure products according to the size, air volume, filter specifications and installation conditions of the project.

22. What information is required for the top-intake high-efficiency air supply outlet project?

Recommendations for new clean room projects include:

Clean room use → Cleanliness level → Design air volume → Filter level → Filter size → Ceiling size → Installation height → Top air duct size → Product quantity

If it is a renovation project, we can also provide:

Original air outlet size → Original filter size → Air duct size → Ceiling photo → Installation space → Original system air volume

This can more accurately determine the specifications of the top-inlet high-efficiency air supply outlet.

23. Aili industrial top air inlet high-efficiency air supply outlet

Aili industrial ceiling-intake high-efficiency air supply vents adopt a top-intake structure and are suitable for clean air systems that require air ducts to be connected from above the ceiling.

Products can be configured based on HEPA filter size, design air volume, ceiling module, air duct specifications and installation space.

Standard specifications cover different sizes and air volume requirements, while supporting non-standard sizes, OEM and ODM customization.

For clean room construction, renovation, laboratories, electronic manufacturing, pharmaceuticals and other clean air treatment projects, the cleanliness level, design air volume, filter specifications, ceiling dimensions and top air duct parameters can be provided to Aili Industrial, and engineers will match products according to project conditions.

24. Contact Aili Industrial

Top air inlet → HEPA high-efficiency filtration → Clean air terminal air supply

Aili Industrial provides:

Top-inlet high-efficiency air supply outlet → Ordinary high-efficiency air supply outlet → Liquid tank sealed high-efficiency air supply outlet → Disposable high-efficiency air supply outlet → HEPA BOX → HEPA high-efficiency filter → FFU → EFU → BFU

Provide project parameters → Confirm filter specifications → Confirm design air volume → Confirm ceiling size → Confirm top air duct → Confirm product model → Obtain product configuration plan

Previous article: 
Next article: 
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.