news

Why is the V-shaped high-efficiency filter without partitions suitable for large air volume systems? Ai Li Industrial

Number of views: 2931     Author: Editor of this site Release time: 2026-08-29 Source: This site

Inquiry

['facebook','twitter','linkedin','pinterest','whatsapp']

Why is the V-shaped high-efficiency filter without partitions suitable for large air volume systems?

1. Core requirements for filters in large air volume systems

In large air volume application scenarios such as large HVAC systems, air conditioning unit (AHU) terminals, and clean factory ventilation systems, filters face completely different working conditions from those at the terminal end of ordinary clean rooms:

The air volume of systems with large air
volume is usually tens of thousands to hundreds of thousands m³/h, which requires a single filter to have a high air volume carrying capacity.

The space inside the air conditioning box is limited
and the internal space is tight, so it is required to achieve the largest possible filtration area within the limited volume.

The operating cost-sensitive
fan operates 24 hours a day, and the filter resistance directly determines the energy consumption level.

Consider maintenance frequency.
Filter replacement requires shutdown operations, and replacement frequency directly affects system availability and maintenance costs.

Although ordinary flat-plate high-efficiency filters without partitions have high filtration efficiency, they have obvious limitations in the above dimensions - the filtering area is limited by the projected area of ​​the frame, the air volume carrying capacity of a single unit is limited, and the resistance is relatively high. The V-shaped high-efficiency filter without partitions is a solution designed to address these pain points.

2. Core technical advantages of V-type partitionless high-efficiency filter

The reason why V-shaped high-efficiency filter without partitions (also known as V-Bank filter and combined high-efficiency filter) has become the first choice for large air volume systems is mainly based on the following technical features:

(1) The filtration area is greatly increased

The V-type filter uses multiple filter elements without partitions to form a V-shaped (or W-shaped) structure. Under the same external dimensions, the filtering area can reach 3 to 5 times that of ordinary filters . Taking the common specification of 610×610×292mm as an example, the V-shaped structure folds the filter material into multiple V-shaped units, and the effective filtration area is far greater than that of a flat filter of the same size.

A larger filter area means that under the same air volume, the speed of air flowing through the filter material is lower, the resistance is smaller, and the dust holding capacity is higher.

(2) Outstanding large air volume carrying capacity

Due to the substantial increase in filtration area, the rated air volume of the V-type filter is significantly higher than that of ordinary high-efficiency filters. The rated air volume of standard size products can reach 2400-4200m³/h . This means that for the same air volume demand, fewer filters are required and the installation space is smaller.

(3) Low resistance operation

The initial resistance of the V-type filter can be as low as ≤200Pa . Taking the common H14 grade V-type filter with 592×592×296mm specifications as an example, the initial resistance is about 250Pa when the rated air volume is 3000m³/h. Compared with traditional high-efficiency filters with partitions, the resistance can be reduced by about 30%.

Low resistance directly brings about a reduction in fan energy consumption. For HVAC systems that operate all year round, the long-term benefits brought by energy consumption savings are very considerable.

(4) High dust holding capacity and long service life

The partition-less design of the V-shaped filter combined with the V-shaped structure makes full use of the depth direction of the filter material, significantly increasing the dust holding capacity. Higher dust holding capacity means longer replacement intervals and less frequent maintenance.

(5) Adapt to variable air volume system

V-type filters are suitable for both constant air flow and variable air flow (VAV) systems. Its rugged construction ensures stable performance in high wind speeds and turbulent conditions. Under the initial resistance condition of 250Pa, the wind speed can reach 2.5m/s.

3. Specific advantages of V-type filters in large air volume systems

Compared with ordinary high-efficiency filters, V-shaped high-efficiency filters without partitions have the following specific advantages in large air volume systems:

1. Reduce the number of filters

Under the same air volume, the number of installations required for V-type filters is significantly less than that of ordinary flat-type filters. Taking a system with a total air volume of 10000m³/h as an example, if ordinary 610×610×70mm partitionless filters (rated air volume ~1000m³/h) are used, 10 units are needed; if V-type filters (rated air volume up to 3000m³/h) are used, only 3-4 units are needed.

2. Save installation space

Reducing the number of filters directly leads to savings in installation space. The compact design of the V-shaped filter gives it a clear advantage in equipment with limited space such as air conditioning boxes.

3. Reduce installation costs

Fewer filters means fewer installation hours, fewer seals and lower shipping costs.

4. Reduce operating energy consumption

The low resistance feature significantly reduces fan energy consumption. For HVAC systems that operate year-round, the long-term benefits from energy savings are considerable.

5. Extend the replacement cycle

The high dust holding capacity design makes the V-type filter have a longer service life than ordinary filters, reducing the frequency of downtime replacement and maintenance labor costs.

4. Typical application scenarios

V-shaped high-efficiency filters without partitions are mainly used in the following large air volume scenarios:

The air conditioning unit (AHU) end filtration
is a high-efficiency filtration at the end of the air conditioning system, achieving large air volume purification with low resistance.

the electronics and semiconductor industry .
Large air volume ventilation system for electronic clean workshops and semiconductor manufacturing plants in

Pharmaceutical and medical industries,
pharmaceutical GMP workshops, hospital operating rooms and other places that have strict requirements on air cleanliness.

Industrial ventilation such as power plants
and ventilation facilities requiring large air volumes.

Commercial Building HVAC
Central air conditioning systems for large commercial buildings.

5. Key points for selection

When choosing a V-shaped high-efficiency filter without partitions, it is recommended to pay attention to the following parameters:

Selection parameters

reference range

illustrate

efficiency level

H13/H14 (EN1822)

Choose according to cleanliness level requirements

Rated air volume

2400-4200m³/h

Match according to system air volume

initial resistance

≤200-250Pa

The lower the energy saving

Overall dimensions

Standard or customized

Need to match the installation space

Frame material

Galvanized steel plate/aluminum alloy/ABS

Choose according to environment

Selection steps:

Step 1: Determine the total air volume requirement
Calculate the total air supply volume of the HVAC system or clean room.

Step 2: Determine the air volume of a single filter
. Determine the rated air volume of each filter based on the installation space and budget. Under the same total air volume, the greater the air volume of a single unit, the smaller the required quantity.

Step 3: Select the efficiency level and
select H13 or H14 level according to the cleanliness requirements.

Step 4: Check the resistance to
confirm that the initial resistance is within the tolerable range of the system fan, and reserve a margin for the final resistance (usually 2 times the initial resistance).

Step 5: Confirm the installation dimensions.
Measure the available space in the air conditioning box or installation location to ensure that the filter dimensions match.

6. Product features of Aili Industrial V-shaped high-efficiency filter without partitions

Aili Industry has the following characteristics in the field of V-type partitionless high-efficiency filters:

Independent production of the entire industry chain
Aili Industry has been deeply involved in the field of purification equipment for more than 20 years, and has built a closed loop of the entire industry chain from fan research and development, control system development to high-efficiency filter production. The key components required for the V-type high-efficiency filter are independently developed, produced and tested by the company to ensure the matching between the components and the overall performance of the system.

Strictly following international standards
, Aili Industrial V-type partitionless high-efficiency filters strictly comply with EN 1822 standards. The filtration efficiency levels cover H13 and H14, and the filtration efficiency for 0.3μm particles can reach 99.97%-99.99%.

The rated air volume of large air volume design
products covers the range of 2400-4200m³/h, adapting to the terminal needs of various large air volume HVAC systems and air conditioning boxes.

Low resistance and high dust holding capacity
adopts a V-shaped structure design combined with a partition-less layout. The initial resistance can be as low as ≤200Pa, the filtration area can be 3-5 times that of ordinary filters, and the dust holding capacity is significantly increased.

Multi-material outer frame Optional
outer frame materials include galvanized steel plate, aluminum alloy, ABS plastic and other choices to adapt to different installation environments and budget needs.

.
Each V-type high-efficiency filter undergoes strict scanning and leak detection testing before leaving the factory to ensure that the efficiency and resistance indicators meet the requirements

If you want to know more about the selection details of V-type partitionless high-efficiency filters, you can contact the Aili industrial engineering technical team to obtain selection suggestions for specific application scenarios.

6. Related FAQs

  • How to install HEPA high efficiency filter?
    HEPA installation should be carried out according to the airflow direction and installation drawing confirmed on site: first check the filter and frame, then clean the installation surface, press the seal evenly, and finally verify the air volume and seal under specified operating conditions.
    HEPA installation, construction and maintenance
  • What should I do if the high-efficiency filter is installed backwards?
    When it is found that the HEPA installation direction is inconsistent with the product or box identification, the acceptance of this position should be suspended, the supplier's drawings and airflow arrows should be checked, and then adjusted according to the allowed installation method. Just because the filter fits into the frame doesn't mean the orientation is correct.
    HEPA installation, construction and maintenance
  • What parameters need to be provided when purchasing HEPA high-efficiency filters?
    When purchasing HEPA, you should at least clarify the outer frame size, efficiency level and applicable standards, rated air volume, resistance, structure, sealing method, use environment and testing data requirements. The old filter element replacement project also requires installation frame and disassembly and assembly path information.
    HEPA procurement selection and application
  • Why are the prices of high-efficiency filters so different?
    Differences in high-efficiency filter quotations may come from efficiency levels, filter materials, structural dimensions, resistance requirements, sealing methods, detection range and order quantity. When comparing prices, you should first confirm whether each quotation corresponds to the same technical conditions.
    HEPA procurement selection and application
  • What should you pay attention to when installing a liquid tank high-efficiency filter? Installation steps and key points
    The installation quality of the liquid tank high-efficiency filter directly affects the sealing effect and cleanliness. Before installation, it is necessary to check that the appearance of the filter is not deformed or damaged, that the liquid tank is intact, and that the box knife edge is flat and free of burrs. During installation, pay attention to controlling the injection amount of sealant to 70%-80% of the depth of the liquid tank, and inject glue evenly and continuously along the periphery of the liquid tank. The filter must be vertically embedded in the knife edge and pushed into place; after installation, it is recommended to conduct a visual inspection, a PAO leak test and an initial resistance record. Common problems include sealant overflow (too much glue), insufficient sealant (too little glue), difficulty in pushing the filter (skew or size mismatch), and PAO leak detection frame leakage (insufficient insertion depth or missing glue). Aili industrial liquid tank high-efficiency filter is provided with polyurethane sealant and installation guidance materials, and the engineering technical team can provide installation technical guidance support.
    HEPA installation, construction and maintenance
  • Which clean rooms are suitable for liquid tank sealed high-efficiency filters? Detailed explanation of application scenarios and level requirements
    The liquid tank high-efficiency filter and the ordinary non-partition high-efficiency filter belong to the non-partition filter category. The core difference lies in the frame structure and sealing method. The liquid tank filter frame has a liquid tank groove, and liquid sealant is injected to achieve sealing. The sealant flows and fills all irregular gaps. It has high long-term reliability and is suitable for ISO class 5 and above clean rooms. Ordinary filters without partitions are sealed by sealing tape extrusion, with a simple structure and low cost, and are suitable for ISO class 5 and below scenarios. The filtration area of ​​the tank filter of the same size is slightly smaller (about 5%-10% less), the price is higher, and the replacement operation is cleaner. When selecting a model, a comprehensive judgment must be made based on the cleanliness level, leak detection requirements, replacement frequency and budget. Aili Industrial produces two types of filters at the same time, with efficiency levels covering H13, H14 and U15-U17. Each unit has been tested and a test report has been issued.
    HEPA procurement selection and application
  • What is the difference between a liquid tank high-efficiency filter and an ordinary high-efficiency filter without partitions?
    The liquid tank high-efficiency filter and the ordinary non-partition high-efficiency filter belong to the non-partition filter category. The core difference lies in the frame structure and sealing method. The liquid tank filter frame has a liquid tank groove, and liquid sealant is injected to achieve sealing. The sealant flows and fills all irregular gaps. It has high long-term reliability and is suitable for ISO class 5 and above clean rooms. Ordinary filters without partitions are sealed by sealing tape extrusion, with a simple structure and low cost, and are suitable for ISO class 5 and below scenarios. The filtration area of ​​the tank filter of the same size is slightly smaller (about 5%-10% less), the price is higher, and the replacement operation is cleaner. When selecting a model, a comprehensive judgment must be made based on the cleanliness level, leak detection requirements, replacement frequency and budget. Aili Industrial produces two types of filters at the same time, with efficiency levels covering H13, H14 and U15-U17. Each unit has been tested and a test report has been issued.
    HEPA procurement selection and application
  • Can V-type high-efficiency filters be made into H13 and H14 grades? Efficiency standards and selection reference
    V-type high-efficiency filters can reach H13 and H14 levels of EN1822:2009 standards. The total MPPS efficiency of H13 is ≥99.95%, and the local penetration rate is ≤0.25%; the total MPPS efficiency of H14 is ≥99.995%, and the local penetration rate is ≤0.025%. H13 is suitable for ISO7-8 clean rooms, electronic assembly, food processing and other scenarios; H14 is suitable for ISO5-6 clean rooms, pharmaceutical GMP, hospital operating rooms, semiconductor manufacturing and other key places. The V-shaped filter is designed with a V-shaped structure and can achieve large air volume carrying and controllable resistance in both H13 and H14 grades. When selecting, a comprehensive judgment must be made based on cleanliness level requirements, industry specifications and system air volume. Aili industrial V-type high-efficiency filters strictly comply with the EN1822 standard, and the efficiency levels cover H13 and H14. H14-level products are scanned and tested for leaks one by one, and test reports are provided.
    HEPA procurement selection and application
  • How should the initial resistance of the V-type high-efficiency filter be viewed? Interpretation of resistance parameters and reference for selection
    The initial resistance is the pressure difference value of the new V-type high-efficiency filter under the rated air volume, in Pa, which is the basic parameter for selection, operation and maintenance. The initial resistance of V-type filter H13 grade is usually ≤200Pa, and the initial resistance of H14 grade is usually ≤250Pa. Under the same conditions, the resistance of H14 is slightly higher than H13. The initial resistance is used for fan head calculation and energy consumption assessment during selection, and is used as a basis for replacement judgment during operation - the final resistance is usually set to twice the initial resistance. When the actual measured initial resistance is high, it is necessary to check whether the actual air volume matches the rated air volume, and check whether the installation is standardized. Initial resistance is an important parameter affecting operating costs. Aili Industrial V-type high-efficiency filter is designed with low resistance. The initial resistance of H13 is ≤200Pa, and the initial resistance of H14 is ≤250Pa. Each unit has been tested for resistance and a test report has been issued.
    HEPA high efficiency filter parameters
  • Can V-type high-efficiency filters be used in constant air volume and variable air volume systems? CAV and VAV compatibility analysis
    V-type high-efficiency filters are suitable for both constant air volume (CAV) and variable air volume (VAV) HVAC systems. The air volume of the CAV system is constant and the working conditions are stable. The V-shaped filter can take advantage of low resistance and high efficiency when selected according to the designed air volume. The air volume of the VAV system is dynamically adjusted as the load changes. The V-shaped filter has a strong structure and good adaptability to wide wind speeds. The wind speed can reach 2.5m/s under the initial resistance condition of 250Pa, adapting to wind speed fluctuation conditions. When selecting the VAV system, the maximum design air volume should be used as the basis, and a 20%-30% fan pressure head margin should be reserved. It is also recommended to configure a differential pressure transmitter to monitor the resistance in real time. V-type filter efficiency grade (H13/H14) does not affect the adaptability of the air volume system. Aili Industrial V-type high-efficiency filter has a solid structure, rated air volume covering 2400-4200m³/h, and is suitable for CAV and VAV systems. Each unit has been scanned and tested for leaks one by one and a test report has been issued.
    HEPA procurement selection and application
  • How to choose the size and air volume of large air volume V-type high-efficiency filter? Detailed explanation of selection parameters and steps
    The selection of large air volume V-type high-efficiency filter requires comprehensive consideration of four core parameters: rated air volume, overall size, initial resistance and efficiency level. Common specifications include rated air volume covering 850-4200m³/h, external dimensions ranging from 287×592×292mm to 1220×610×292mm, and initial resistance as low as ≤200Pa. The selection steps include calculating the total air volume of the system, determining the air volume requirement of a single unit, selecting the overall dimensions according to the parameter table, checking the installation space (especially the depth direction, the standard is 292mm), selecting the efficiency level (H13 or H14), checking the initial resistance and evaluating the replacement cycle. It is recommended to reserve 10%-20% air volume margin when selecting a model to avoid neglecting the depth size, the impact of efficiency level on air volume, and the difference between initial resistance and final resistance. Aili Industrial provides a variety of dimensions and V-shaped configurations, with rated air volume covering 850-4200m³/h. It strictly complies with the EN1822 standard. Each unit has been scanned and tested for leaks one by one and a test report has been issued.
    HEPA procurement selection and application
  • How to increase the filtration area of ​​V-type high-efficiency filter in a limited space? Structural principles and key points for selection
    The V-type high-efficiency filter is arranged in a V-shape with multiple filter elements without partitions, which increases the filtration area to 3-5 times that of ordinary flat-plate filters under the same external dimensions. Its core principle is to expand the filter material from a two-dimensional plane to a three-dimensional space, making full use of the depth direction of the frame. The increased filtration area brings practical advantages such as low resistance (initial resistance can be as low as ≤200Pa), large air volume (rated air volume can reach 2400-4200m³/h), high dust holding capacity and reduced number of filters. V-type filters are suitable for large air volume scenarios in limited spaces such as the end of air-conditioning boxes, compact HVAC systems, return air ducts in clean factories, and upgrades of existing systems. When selecting, you need to confirm the installation depth, select a V-shaped configuration according to the air volume, and check the system resistance. Aili industrial V-type high-efficiency filters strictly comply with the EN1822 standard and are available in 3V, 4V, and 5V specifications. Each unit has been scanned and tested for leaks one by one and a test report has been issued.
    HEPA procurement selection and application
  • Which HVAC air handling systems are suitable for V-Bank high-efficiency filters?
    V-Bank high-efficiency filter (V-type combined high-efficiency filter) uses multiple filter elements without partitions to form a V-shaped structure. The rated air volume can reach 2400-4200m³/h. It is suitable for constant air volume (CAV) and variable air volume (VAV) HVAC systems. Typical application scenarios include hospital operating rooms and ICUs, pharmaceutical GMP workshops, electronic and semiconductor clean workshops, food processing plants, data centers, hotels and schools and other commercial buildings, as well as industrial ventilation facilities such as power plants. V-Bank filters can be used as high-efficiency filtration or ULPA pre-protection at the end of air conditioning boxes in HVAC systems. They have technical advantages such as large air volume carrying capacity, low operating resistance, high dust holding capacity, and saving installation space. Aili Industrial V-Bank high-efficiency filters strictly comply with EN1822 standards, with efficiency levels covering H13 and H14, adapting to the needs of various HVAC air treatment systems. Each unit has been scanned and tested for leaks one by one and a test report has been issued.
    HEPA procurement selection and application
  • Why is the V-shaped high-efficiency filter without partitions suitable for large air volume systems? Ai Li Industrial
    The V-type partitionless high-efficiency filter uses multiple partition-less filter elements to form a V-shaped structure. The filtration area can reach 3-5 times that of ordinary filters, the rated air volume can reach 2400-4200m³/h, and the initial resistance can be as low as ≤200Pa. In large air volume systems, compared with ordinary high-efficiency filters, V-type filters have the advantages of reducing the number of filters, saving installation space, reducing installation costs, reducing operating energy consumption, and extending the replacement cycle. The efficiency level covers H13 and H14, and is suitable for large air volume scenarios such as terminal filtration of air-conditioning boxes, electronic semiconductors, pharmaceuticals and medical care, and power plants. When selecting, you need to pay attention to parameters such as rated air volume, initial resistance, efficiency level, and overall dimensions. Aili Industrial V-type partitionless high-efficiency filter strictly complies with the EN1822 standard and provides large air volume design, low resistance and high dust holding capacity, optional multi-material frames and unit-by-unit inspection services.
    HEPA procurement selection and application
  • What is a V-type high-efficiency filter, and what is the difference between it and an ordinary high-efficiency filter?
    The V-type high-efficiency filter (V-Bank) uses multiple filter elements without partitions to form a V-shaped structure. The filtration area can reach 3-5 times that of ordinary filters. The designed air volume is more than 2 times higher than that of high-efficiency filters with partitions. The initial resistance can be as low as ≤200Pa. Compared with ordinary high-efficiency filters, V-type filters require fewer installations, smaller installation space, lower operating resistance, higher dust holding capacity and longer service life under the same air volume. The efficiency level covers H13 and H14, and is mainly used in scenarios such as terminal filtration of air-conditioning boxes, large air volume HVAC systems, electronic semiconductors, pharmaceuticals, medical and power plants. Aili industrial V-type high-efficiency filters strictly comply with the EN1822 standard, provide multiple specifications and are tested one by one, and support customized production.
    HEPA procurement selection and application
  • How to choose the thickness and filtration area of ​​a high-efficiency filter without partitions?
    The thickness (50mm, 70mm, 90mm, 120mm) and filter area of ​​the high-efficiency filter without partitions directly affect the air volume carrying capacity, initial pressure difference, dust holding capacity and service life. 70mm is the standard configuration of FFU, which strikes a balance between space occupation and performance; 90mm and 120mm are suitable for equipment with ample space such as air-conditioning boxes, with larger filter area and longer replacement cycle. When selecting, a comprehensive judgment must be made based on the size of the installation space, system air volume, fan head margin and full life cycle cost. If space allows, choosing a thicker filter, lower energy consumption and longer replacement intervals can usually pay back the cost difference within 1-2 years. Aili Industrial provides multiple thickness specifications of 50-120mm and non-standard customization services. Each unit is scanned and tested for leaks one by one and a test report is issued. The engineering and technical team can assist in air volume calculation and resistance calculation.
    HEPA procurement selection and application
  • Can high-efficiency filters without partitions be made into H13, H14 and ULPA grades?
    The partition-less high-efficiency filter uses ultra-fine glass fiber filter paper and hot-melt adhesive line separation technology, and can cover the full range of efficiency levels of H13, H14 and ULPA U15, U16, and U17. According to the EN1822 standard, H13 efficiency ≥ 99.95%, H14 ≥ 99.995%, U15 ≥ 99.9995%, U16 ≥ 99.99995%, U17 ≥ 99.999995%. Different levels correspond to different cleanliness requirements - H13 is suitable for ISO 7-8 clean rooms, H14 is suitable for ISO 5-6 clean rooms, and the local penetration rates of H13 and H14 differ by ten times. ULPA conducts efficiency assessments in the particle size range of 0.1-0.2μm and is suitable for high cleanliness environments of ISO level 4 and above. When selecting a model, a comprehensive balance must be made based on the cleanliness level, industry standards, system air volume and budget. Aili Industrial has independent production capabilities across the entire industry chain and strictly follows the EN1822 standard. Each filter is scanned and tested for leaks one by one and a test report is provided. It supports full series customization of H13, H14 and U15-U17.
    HEPA procurement selection and application
  • Should you choose a high-efficiency filter without partitions when space is limited?
    When the installation space of FFU, EFU, clean shed or other clean equipment is limited, high-efficiency filters without partitions can be considered. The partition-less structure uses glue lines to fix the fold distance of the filter material, and has a certain design space in terms of filter thickness, filter area and internal structure. The actual selection should not only focus on the thickness of the filter, but also need to comprehensively consider the filtration efficiency, target air volume, initial resistance, fan static pressure, sealing method and later replacement space. Aili Industry can match the specifications of high-efficiency filters without partitions based on the equipment installation dimensions and operating parameters.
    HEPA procurement selection and application
  • Which electronic, semiconductor and pharmaceutical clean rooms are suitable for partitionless high-efficiency filters?
    Partitionless high-efficiency filters can be used in clean environments such as semiconductors, electronic manufacturing, photovoltaics, pharmaceuticals, laboratories and precision manufacturing according to different specifications, and are often used in conjunction with FFU, EFU, clean sheds and clean room terminal air supply equipment. Different applications have different requirements for filtration efficiency, air volume, resistance, size, thickness and sealing methods, so selection needs to be based on specific equipment and clean environments. Aili Industry can match the specifications of high-efficiency filters without partitions based on industry applications, equipment structures and project parameters.
    HEPA procurement selection and application
  • What are the common structures and specifications of high-efficiency filters without partitions?
    High-efficiency filters without partitions usually adopt filter material folding, glue line separation and outer frame sealing structure, without using traditional paper partitions or aluminum partitions. Its specifications mainly include overall dimensions, thickness, filtration efficiency, air volume, initial resistance, outer frame material and sealing method, etc. When used in FFU, EFU, clean sheds and clean room terminal air supply equipment, it needs to be matched based on the installation space, fan performance and target air volume. Aili Industry can provide corresponding specifications and configurations of high-efficiency filters without partitions based on equipment size, air volume, filtration efficiency and usage environment.
    HEPA filter structure

Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.