Number of views: 921 Author: Editor of this site Release time: 2026-09-09 Source: This site
When selecting an efficient air supply outlet , you usually need to focus on the following parameters:
Design air volume, filter grade, filter size, box size, system static pressure, air inlet method, ceiling size, installation height, maintenance space and sealing structure.
The most core parameters can be summarized as:
The air volume determines how much air is sent, the filter determines the filtration configuration, the size determines whether it can be installed, the static pressure determines whether the system matches, and the air inlet method determines how to connect the air duct.
Therefore, when purchasing high-efficiency air supply vents, you should not just ask:
'How much does this air outlet cost?'
You should first determine:
'Does the air volume, filter, size and interface of this air supply vent match my clean room system?'
Design air volume is an important parameter for selecting efficient air supply vents.
The efficient air supply outlet ultimately needs to meet the end air supply needs of the clean room, so it needs to be determined first:
Total air supply volume of clean room
Then according to:
Total air supply volume ÷ number of air supply outlets
Obtain the average design air volume of a single air supply outlet.
For example:
Total air supply volume 6000m³/h ÷ 12 air supply outlets = 500m³/h/each
Then a single air supply outlet can use approximately 500m³/h as a preliminary selection reference.
The actual product also needs to be combined with:
Filter resistance + system static pressure + air flow organization + air supply speed
to confirm.
High-efficiency air supply vents are usually equipped with HEPA or ULPA filters.
Common filtering levels include:
H13, H14, U15, U16, U17
Things to consider when choosing:
Cleanliness level
Process requirements
target particle size
Filtration efficiency
filter resistance
Project acceptance requirements
therefore:
The filter grade should be determined based on actual cleanliness requirements, rather than simply assuming that a higher grade is more suitable for all projects.
The size of the filter directly affects the structure of the air supply box.
Need to confirm:
Length × Width × Thickness
as well as:
Installation frame size + sealing structure + compression method
For example, HEPA filters of different sizes will have different sizes of matching air outlet boxes.
Therefore, it is best to provide:
Filter specifications + air outlet dimensions + ceiling opening dimensions
Avoid size mismatches on site.
Common requirements for high-efficiency air supply vents include:
Length×width×height
in:
Main impact:
ceiling module
filter size
Opening size
Main impact:
Space above suspended ceiling
Static plenum space
Duct connection
Filter maintenance
If the height of the technical mezzanine is relatively limited, the height of the cabinet needs to be confirmed carefully.
High-efficiency air supply vents are part of the overall air handling system.
Typical system:
MAU/AHU → Main air duct → Branch air duct → High-efficiency air supply outlet → HEPA/ULPA → Clean room
Therefore, the air supply outlet selection needs to match the system static pressure.
Need to consider:
Duct resistance + air supply outlet resistance + filter resistance + other system resistance
If the system static pressure is insufficient, the design air volume may not be achieved.
therefore:
High-efficiency air supply outlets cannot determine the air volume independently of the entire air duct system.
Mainly divided into:
Head into the wind
and
Side air intake
Air duct → Top interface → Static pressure box → HEPA/ULPA → Clean room
Suitable for air ducts connected from the top.
Air duct → Side interface → Static pressure box → HEPA/ULPA → Clean room
Suitable for air ducts connected from the side.
The main basis for selection is:
Air duct location + ceiling structure + technical mezzanine space
Sure.
If the high-efficiency air supply vent is installed on the clean room ceiling, the ceiling module must be confirmed.
Need to check:
Ceiling board size → Air supply outlet size → Opening size → Fixing method
Especially for modular clean rooms, the air supply vents and ceiling panels need to be matched in size.
The installation height mainly includes:
Cabinet height + ceiling space + air duct connection space
If the technical mezzanine height is relatively small, you need to focus on:
Cabinet height
Duct height
Filter replacement space
Inspection space
Electrical or other pipelines
After the high-efficiency air supply vent is installed, the HEPA or ULPA filter needs to be maintained and replaced.
Therefore, you need to confirm in advance:
Filter disassembly and assembly direction + maintenance space + inspection channel
If a structure is used for maintenance from below, it is necessary to confirm whether there is sufficient operating space inside the clean room.
If maintenance is performed from above, it is necessary to confirm whether the technical mezzanine above the suspended ceiling can be operated.
Sealing needs to be considered between the high-efficiency air supply outlet and the clean room ceiling, and between the filter and the installation frame.
Need attention:
Box flange
sealing material
Filter sealing structure
compression structure
Ceiling seams
During model selection, if the project has high sealing requirements, the sealing structure and installation method of the product should be confirmed in advance.
From a procurement and engineering perspective, parameters can be divided into five categories:
Parameter category |
Main parameters |
Main function |
|---|---|---|
Air parameters |
Air volume, static pressure, air supply speed |
Determine air supply capacity |
Filter parameters |
H13/H14/U15/U16/U17, filter size |
Determine filtering configuration |
Structural parameters |
Length, width, height, box material |
Determine product structure |
Installation parameters |
Top air inlet, side air inlet, interface size, ceiling opening |
Confirm on-site installation |
Maintenance parameters |
Filter replacement direction and maintenance space |
Determine subsequent maintenance |
This makes it easier to judge whether the product is suitable for the project than simply looking at a product parameter table.
Matching can be performed according to the following logic:
Clean room known conditions |
Corresponding product parameters |
|---|---|
Cleanliness level |
HEPA/ULPA filter |
Room area |
Total air supply volume |
room height |
Number of air supply outlets and installation conditions |
total air volume |
Air volume of a single air outlet |
Ceiling size |
Air supply vent shape and opening |
Duct location |
Top air intake/side air intake |
Technical mezzanine height |
Cabinet height |
System static pressure |
Filter and air outlet resistance matching |
Maintenance method |
Filter disassembly and assembly space |
Usage environment |
Cabinet material |
It cannot simply be said that only one is most important.
For actual projects, it is recommended to give priority to:
① Design air volume
② Filter level
③ Filter size
④ Air outlet size
⑤ System static pressure
⑥ Air intake method
⑦ Ceiling size
⑧ Maintenance space
These parameters are related to each other.
For example:
Air volume → affects filter and air outlet selection
Filter size → affects box size
Box size → affects ceiling and installation space
The position of the air duct → affects the top air inlet/side air inlet
Therefore, comprehensive selection is still required in the end.
If the manufacturer produces a product parameter sheet, it is recommended to include at least:
parameter |
Suggested annotations |
Is project confirmation required? |
|---|---|---|
Product name |
Efficient air outlet |
yes |
English name |
High Efficiency Air Supply Outlet |
no |
Overall dimensions |
L×W×H |
yes |
Design air volume |
m³/h |
yes |
Filter level |
H13/H14/U15/U16/U17 |
yes |
filter size |
L×W×H |
yes |
Air intake method |
Top air intake/side air intake |
yes |
Interface size |
Determine based on product |
yes |
Cabinet material |
Determine according to project |
yes |
Sealing method |
Determine based on structure |
yes |
Installation method |
Suspended ceiling/other |
yes |
Maintenance method |
above/below etc. |
yes |
Aili industrial high-efficiency air supply vents can match product parameters according to the actual conditions of the project.
When selecting, you can choose from:
Cleanliness level → Design air volume → Filter → Box size → Air inlet direction → Air duct interface → Ceiling size → Maintenance space
Confirm item by item.
Aili Industrial also has:
Sheet metal structure, HEPA/ULPA filters, fans, motors, FFU, EFU and control systems
and other products and supporting capabilities.
Therefore, if a project requires not only efficient air supply vents, but also:
HEPA/ULPA filter + FFU + EFU + fan + control system
Can be combined and configured according to the project air handling system.
For equipment-level clean applications, you can further compare products such as EFU.
You can directly confirm according to the form below before purchasing:
project |
Confirmed content |
|---|---|
Cleanliness level |
______ |
Room area |
______ |
Room height |
______ |
total design air volume |
______ |
Number of air outlets |
______ |
Air volume of a single air outlet |
______ |
Filter level |
______ |
filter size |
______ |
Cabinet size |
______ |
Air intake method |
Top air inlet / side air inlet |
Air duct interface |
______ |
Ceiling size |
______ |
Technical mezzanine height |
______ |
Maintenance direction |
______ |
Cabinet material |
______ |
Sealing requirements |
______ |
It mainly depends on the design air volume, filter grade, filter size, box size, system static pressure, air inlet method, ceiling size, installation height and maintenance space.
need. The air supply vents and filters both create resistance and need to match the static pressure conditions of the entire duct system.
need. Air volume is an important parameter in determining the size and quantity of air supply outlets.
Different HEPA or ULPA levels can be configured according to project requirements, such as H13, H14, U15, U16, and U17.
Filter size, ceiling modules, installation openings, box structure and duct connections need to be considered simultaneously.
The main difference lies in the duct connection direction and installation conditions. The top air inlet is connected to the air duct from the top of the box, and the side air inlet is connected to the air duct from the side of the box.
There is no fixed size that applies to all products. It needs to be determined based on the filter size, disassembly and assembly methods, box structure and on-site maintenance conditions.
no. The air volume needs to match the clean room design, number of air supply outlets, airflow organization, filter resistance and system static pressure.
uncertain. HEPA Box is usually used to describe the box or filter terminal structure with a HEPA filter. The specific meaning needs to be judged based on the product structure. It is more suitable to use High Efficiency Air Supply Outlet as a universal English expression.
is recommended High Efficiency Air Supply Outlet . If you emphasize HEPA filtration function, you can use HEPA Air Supply Outlet or HEPA Filtered Air Supply Outlet。
The selection of efficient air supply outlets mainly focuses on five types of parameters:
Air parameters → Filtration parameters → Structural parameters → Installation parameters → Maintenance parameters
The core can be summarized as:
Air volume + filter + size + static pressure + air intake method + ceiling + maintenance space
in:
Air volume determines air supply demand
Filter determines filtering configuration
Size determines whether the product can match the suspended ceiling
Static pressure determines system operating conditions
The air inlet method determines the air duct connection
Maintenance space determines whether the filter can be easily replaced later
Therefore, a complete selection of high-efficiency air supply outlets cannot only look at a certain parameter in the product catalog, but should be determined in conjunction with the overall air treatment system of the clean room.
Aili Industrial can cleanliness level, design air volume, ceiling size, air duct location, filter requirements and installation space .further match products such as high-efficiency air supply vents and HEPA/ULPA filters based on the project's
If you are selecting a high-efficiency air supply outlet for a clean room, we can provide:
Cleanliness level + room area + room height + total air supply volume + number of air supply outlets + ceiling size + air duct location + HEPA/ULPA requirements
Aili Industry can further confirm based on this:
Air volume of a single air supply outlet + filter specification + box size + air inlet method + interface size + installation conditions
And configure efficient air supply outlet products according to actual project conditions.