Cleanrooms require continuous control of airborne dust particles, particulates, and other contaminants that may affect the production or experimental environment.
Merely sending air into the clean room does not guarantee that the air meets the corresponding clean requirements.
Usually you need to go through:
Air treatment → Duct transportation → High-efficiency air supply outlet → HEPA/ULPA filter → Clean room
High-efficiency air supply vents are usually installed on the ceiling or end air supply position of the clean room, and are responsible for filtering and supplying air before it enters the clean area.
Therefore, the main purpose of using high-efficiency air supply vents in clean rooms is to allow the treated air to pass through high-efficiency filters and then enter the clean space in an appropriate manner.
The high-efficiency air supply vent is not a separate device, but a part of the clean room air supply system.
Its main functions can be summarized as:
effect |
Specific content |
|---|---|
end filter |
Configure HEPA or ULPA filters to filter the air entering the clean room |
air transport |
Deliver air from the duct system into the clean area |
airflow organization |
Organize terminal airflow through structures such as diffusers |
static pressure transition |
Complete the air transition between the air duct and the filter through structures such as static pressure boxes |
sealed installation |
Install and seal filters to reduce risk of bypass leaks |
maintain |
Filter inspection and replacement based on structural design |
Therefore, the function of high-efficiency air supply vents can be understood as:
The air in the clean room air supply system is filtered, connected and supplied at the end.
Ordinary air supply outlets are mainly responsible for air transportation and air flow organization functions, and are not equivalent to high-efficiency filter air supply equipment.
Clean rooms often require further filtration of the air entering the room, so a HEPA or ULPA filter is installed at the end.
A typical structure is:
Air conditioning box/air treatment equipment→Air duct→Static pressure box→HEPA/ULPA→Diffusion device→Clean room
The high-efficiency air supply port can integrate the filter installation structure, static pressure box, air supply panel, etc. into one terminal device.
This facilitates engineering installation, filter maintenance and terminal air supply organization.
High-efficiency air supply vents themselves are not equivalent toHEPA filter。
The two are different components.
Simply put:
High-efficiency air supply outlet = terminal air supply structure
HEPA/ULPA = air filter element
High-efficiency air supply vents usually need to be designed to the specifications of the filter so that the filter can be installed, sealed and maintained.
After air enters the high-efficiency air supply vent, it usually passes through:
Air inlet interface → Static pressure box → HEPA/ULPA filter → Diffusion device → Clean room
Therefore, when selecting a high-efficiency air supply outlet, it is necessary to determine the specifications, filtration efficiency, resistance and installation method of the filter at the same time.
The air cleanliness of a clean room is not determined solely by efficient air supply vents.
Typically the entire system is required to work together, including:
air handling equipment
Fresh air system
Duct system
Efficient air outlet
HEPA/ULPA filter
Return air system
airflow organization
Differential pressure control
Clean room enclosure
Among them, the high-efficiency air supply outlet is located at the end position where air enters the clean room.
If the high-efficiency filter is properly installed, sealed and maintained, the air entering the clean room can be filtered at the end before entering the room.
One of the common air supply methods in clean rooms is to supply air downward from the top.
This arrangement can make the filtered air enter the clean area from above according to the air flow organization requirements of the clean room, and then cooperate with the return air system to form the designed air circulation.
A typical layout is:
High-efficiency air supply outlet at the top → clean area → lower/side return air → air treatment system
The specific air supply and return methods need to be designed according to the cleanliness level, room size, equipment layout and process requirements of the clean room.
Not all clean rooms are organized in exactly the same way.
no.
The number of efficient air supply outlets needs to be determined based on the design air supply volume and air flow organization of the clean room.
Common calculation ideas are:
Total air supply volume of the clean room ÷ Design air volume of a single air supply outlet = Theoretical number of air supply outlets
For example:
The total designed air supply volume of the clean room is 6000m³/h, and the designed air volume of a single air supply outlet is 500m³/h.
Theoretical quantity:
6000 ÷ 500 = 12
However, the actual project still needs to adjust the quantity according to the ceiling size, equipment location, return air outlet location and air flow organization.
Therefore, whether the clean room design is reasonable cannot be judged simply by increasing the number of air supply outlets.
It is recommended to confirm from the following aspects:
Selection items |
Main confirmation content |
|---|---|
Cleanliness level |
ISO level and project design requirements |
room size |
length, width, height |
Total air supply volume |
m³/h |
Air volume of a single air outlet |
Determined based on system design |
filter |
HEPA or ULPA |
Filtration efficiency |
Choose according to cleanliness requirements |
filter size |
Match the box structure |
filter resistance |
Matches system static pressure |
Air intake method |
Top air intake, side air intake, etc. |
Installation method |
Ceiling structure and opening dimensions |
Maintenance method |
Filter inspection and replacement |
High-efficiency air supply outlets can be used in a variety of places that require high-efficiency filtered air supply at the end, such as:
semiconductor |
Electronic manufacturing |
medicine |
laboratory |
|---|---|---|---|
Clean factory |
SMT workshop |
Preparation area |
Clean laboratory |
Wafer related area |
Electronic assembly |
pharmaceutical production |
biology laboratory |
Precision manufacturing |
Precision assembly |
Medical related areas |
Testing laboratory |
In addition, it can also be used in photoelectric, food, cosmetics, medical equipment and other areas that require air cleanliness according to project needs.
Efficient air supply vents andBoth FFU can be used for clean room air treatment, but the system forms are different.
Compare items |
Efficient air outlet |
FFU |
|---|---|---|
Does it bring its own fan? |
Usually not brought |
With fan |
Power source |
Rely on centralized air supply system |
Built-in fan provides power |
Typical system |
Air conditioning box + air duct |
FFU modular system |
end filter |
HEPA/ULPA |
HEPA/ULPA |
Control method |
controlled by central system |
Can be controlled individually or in groups |
Applicable features |
Centralized air supply |
Modular clean air supply |
Therefore, if the project already uses centralized air conditioning and ductwork, high-efficiency air vents are often easier to match with the existing system.
If modular air supply is required, you can consider equipment such as FFU.
Aili Industry focuses on clean room air treatment equipment, providing high-efficiency air supply vents, high-efficiency filters, HEPA/ULPA filters, FFU, EFU, fans, motors and control systems and other products.
In the high-efficiency air supply vent project, we can provide:
Cleanliness level → Room size → Design air volume → Filter requirements → Ceiling size → Air intake method → Maintenance method
Perform corresponding product matching.
For clean rooms that use centralized air duct air supply, high-efficiency air supply outlets can be selected based on the terminal air supply volume and filter specifications; for areas that require modular clean air supply, FFU or EFU can be considered based on project conditions.
Aili Industrial has the manufacturing capabilities of fans, motors, filters, sheet metal and control systems, and can provide matching equipment around clean air treatment equipment.
Whether to use high-efficiency air supply outlets needs to be determined based on the overall air supply system of the clean room. Projects that use centralized air ducts for air supply and require high-efficiency filtration at the end can use high-efficiency air supply outlets.
It cannot be understood this way alone. The cleanliness of clean rooms is affected by many factors such as air treatment, filtration, air flow organization, pressure difference, envelope structure and operation and maintenance.
It needs to be determined according to the project design requirements. If high-efficiency filtration is required at the end, a HEPA or ULPA filter is usually configured.
The common installation location is the ceiling of a clean room, but the specific location needs to be determined based on the airflow organization, room layout and return air method.
need. The main maintenance content includes checking the filter status, sealing condition, air volume and operating status, and arranging replacement according to the actual use of the filter.
Clean rooms use high-efficiency air supply outlets mainly to complete terminal filtration, air connection and air flow organization before the air enters the clean area.
Its typical working process is:
Air treatment → Air duct → High-efficiency air supply outlet → HEPA/ULPA filter → Clean room
The high-efficiency air supply outlet is not a device that independently determines the cleanliness of the clean room, but is an end component of the clean room air treatment system. The actual selection needs to be comprehensively determined based on the cleanliness level, design air volume, filter specifications, installation dimensions and air flow organization.