FFU is a kind of clean air equipment that combines fans, air filters, boxes and control functions . It is mainly used to continuously deliver filtered air to clean rooms, clean sheds, production equipment or local clean areas.
When FFU is running, the fan sucks air into the box and establishes air flow and pressure. After the air passes through the HEPA or ULPA filter, the particles in it are filtered, and then sent to the target clean area from the air outlet surface.
FFU basic workflow: air enters → fan establishes air flow → HEPA/ULPA filtration → clean air is sent out → enters the target clean area
FFU can be used as a single device or as a system composed of dozens, hundreds or even more devices. Different projects need to be configured according to the cleanliness level, installation space, air volume and speed, filtration efficiency and control method.
The main function of FFU is to continuously provide filtered air to designated areas and cooperate with clean rooms or production equipment to form the required clean environment.
Application location |
Main function |
Application location |
Main function |
|---|---|---|---|
Clean room top |
Provide filtered air |
Clean shed top |
Establish a local clean space |
semiconductor environment |
With particle control |
Top of production equipment |
Provide clean air at equipment end |
SMT/PCB equipment |
Establish a local clean environment |
Precision manufacturing |
Reduce the impact of particulate matter |
biomedicine |
Clean production air treatment |
laboratory |
Overall or partial cleaning |
Therefore, FFU is not just a 'fan + filter', but an air handling unit in the clean air system.
The working principle of FFU is not complicated.
After the equipment is started, the motor drives the fan to run, and air enters the box from the FFU air inlet area. The fan powers the air flow, allowing the air to overcome filter and system resistance.
The air then passes through a HEPA or ULPA filter, which filters out particulate matter in the air.
The filtered air is sent from the FFU outlet surface to the clean area.
The whole process can be summarized as:
The motor drives the fan → the fan establishes air volume and pressure → the air passes through the filter → particles are filtered → clean air is sent out
When a large number of FFUs are installed on the top of the clean room, they can jointly provide filtered air to the clean area through reasonable system configuration.
Common FFU mainly include cabinets, motors, fans, filters, control systems and air inlet and outlet structures.
FFU composition |
Main function |
FFU composition |
Main function |
|---|---|---|---|
cabinet |
Carrying components and forming air ducts |
Motor |
Drive fan operation |
fan |
Provide air volume and pressure |
HEPA/ULPA |
Filter air particles |
control system |
Start, stop, speed adjustment and management |
Air inlet structure |
air entering equipment |
Air outlet structure |
Output filtered air |
Electrical components |
Power supply, communication and control |
There is a direct relationship between these components.
The filter generates resistance → the fan overcomes the resistance and provides air volume → the motor drives the fan → the control system adjusts the operating status → the box forms an internal air channel
Therefore, FFU selection should be considered from the perspective of the entire machine, rather than just looking at one of its components.
FFU and HEPA are not the same product.
FFU is an air filtration device with a power system, and HEPA is an air filter used for particle filtration.
It can be simply understood as:
FFU = fan system + cabinet + control system + HEPA/ULPA filter
Among them, the fan is responsible for the continuous flow of air, the filter is responsible for filtering particulate matter, and the control system is responsible for equipment operation management.
Therefore, whether the FFU can achieve the designed air volume cannot only depend on the fan, nor can it only depend on the filter.
The fan air volume, air pressure and filter resistance need to be reasonably matched.
FFU can configure different levels of filters according to clean environment and process requirements.
Filter type |
Common grades |
Main selection direction |
Common applications |
|---|---|---|---|
HEPA |
H13,H14 |
Conventional high efficiency filtration |
Clean room, clean equipment |
ULPA |
U15,U16,U17 |
Higher particle filtration requirements |
Semiconductor and high clean applications |
Which one to choose requires comprehensive consideration:
Cleanliness level → Process requirements → Particle control requirements → Filter resistance → Target air volume → FFU fan capacity
It should be noted that higher filtration efficiency is not suitable for all projects.
After the filtration level and filter structure change, parameters such as resistance may also change, so the matching between the fan and filter needs to be reconsidered.
In FFU selection, air volume and wind speed are two parameters that often appear.
Air volume represents the volume of air passing through the equipment per unit time.
Wind speed represents the speed of air passing through a specified section.
Under simplified conditions:
Air volume = effective air outlet area × average wind speed
Therefore, for FFU with the same air outlet area, when the average wind speed changes, the corresponding air volume will also change.
Actual projects also need to consider filter resistance, box structure, system resistance and measurement methods.
Therefore, when purchasing FFU, it is not recommended to just ask 'What is the wind speed?', you should also confirm:
Air volume related |
Wind pressure related |
Filter related |
System related |
|---|---|---|---|
Rated air volume |
External residual pressure |
filter level |
actual system resistance |
average wind speed |
Fan working point |
filter resistance |
Installation conditions |
According to different motor and drive solutions, FFU commonly has AC, DC, EC and other forms.
Different solutions have differences in speed regulation methods, control methods, input power, operating characteristics, and project costs.
For projects that require long-term operation or air volume adjustment according to production status, you can focus on fan efficiency and control methods.
For example, some DC or EC solutions can adjust the speed according to actual working conditions:
Normal production → Working speed | Reduced demand → Reduce operating speed | Maintenance status → Shut down or designated equipment operation
When the fan speed changes, the air volume, wind pressure and input power will also change with the operating point.
The actual energy-saving effect is related to fan characteristics, system resistance, operating time and control strategy, and should be calculated or tested based on specific projects.
Can.
A small number of FFU can be controlled in a relatively simple way.
When dozens, hundreds or even more FFUs are installed in a clean room, centralized control can be adopted depending on the project scale.
The group control system can be implemented according to configuration:
Partition management → Start and stop control → Fan speed setting → Working mode → Duty mode → Single machine status management
Aili Industrial can configure corresponding control solutions based on the number of FFU and project scale.
Small projects can use corresponding controllers; larger projects can be configured with computer group control according to the system design to facilitate the unified operation and management of a large number of FFUs.
Both FFU and EFU can be used for clean air filtration, but the product structure and application direction are different.
Traditional FFU is widely used in clean room ceilings and larger clean areas.
EFU is designed more based on the local cleaning requirements of the equipment.
FFU common applications |
Common applications of EFU |
FFU attention direction |
EFU focus direction |
|---|---|---|---|
clean room |
Semiconductor equipment |
clean coverage |
device space |
Clean shed |
EFEM |
Air volume and speed |
Ultra-thin structure |
production area |
Automation equipment |
Group control |
Non-standard size |
Large area clean |
SMT equipment |
System configuration |
Equipment adaptation |
Therefore it can be simply understood as:
The overall cleanliness of the clean room → Focus on FFU | Partial cleanliness on the equipment side → EFU can be further considered
The final decision still needs to be made based on the installation space, target air volume, filtration level and equipment structure.
FFU has been used in a variety of production and experimental environments that require air cleanliness.
semiconductor |
FPD/LCD/OLED |
Lithium battery |
photovoltaic |
|---|---|---|---|
SMT/PCB electronics |
precision optics |
Precision instruments |
biomedicine |
medical device |
laboratory |
food |
cosmetic |
Different industries may have different requirements for the cleanliness level, air volume, wind speed, filtration efficiency, size, material and control method of FFU.
Therefore, FFU should be configured according to the specific application, rather than using the exact same product parameters for all industries.
It is recommended to confirm at least the following 10 parameters when selecting FFU.
Selection parameters |
Need confirmation |
Selection parameters |
Need confirmation |
|---|---|---|---|
Installation dimensions |
Installation space and opening size |
Air volume |
Target air volume of a single unit |
wind speed |
average wind speed |
Filtration efficiency |
H13/H14/U15 etc. |
Residual pressure |
additional system resistance |
power supply |
Voltage and power supply conditions |
Drive mode |
AC/DC/EC |
Speed regulation method |
Multi-speed or continuous speed adjustment |
Control method |
Single machine/centralized/group control |
Box structure |
Material and installation method |
If it is a semiconductor equipment or automation equipment application, you also need to confirm:
Equipment internal space → Allowable installation height → Inlet and outlet air direction → Equipment structure → Target clean area → Actual operating conditions
Then decide whether to use regular FFU or device-side EFU.
Two FFUs with the same external dimensions do not mean that the internal configuration and overall machine parameters are exactly the same.
possible differences |
Impact on the whole machine |
possible differences |
Impact on the whole machine |
|---|---|---|---|
fan |
Air volume, wind pressure |
filter |
efficiency, resistance |
Motor |
drive, speed regulation |
control system |
Operation management |
Box structure |
Installation, air duct |
Material |
Adaptation to usage environment |
Therefore, when purchasing FFU, a more reasonable comparison method is:
Size + air volume + wind speed + filtration level + residual pressure + power + control method + material + installation method
By comparing different solutions under the same project requirements and technical conditions, it is easier to judge whether FFU is truly suitable for the project.
Aili Industry focuses on R&D and manufacturing of FFU, EFU and clean air equipment.
In the FFU product system, it covers:
Motor→Fan→Control system→HEPA/ULPA filter→Sheet metal→Complete machine assembly and testing
This product system is conducive to collaborative matching of different components according to the operation requirements of the FFU machine.
Project requirements |
Configuration direction |
Project requirements |
Configuration direction |
|---|---|---|---|
Standard clean room |
FFU size and air volume matching |
Semiconductor equipment |
FFU/EFU device adaptation |
height restricted |
Ultra-thin structure |
higher wind speed |
Fan and filter matching |
Centralized operation of multiple units |
FFU group control |
High cleanliness requirements |
HEPA/ULPA matching |
Non-standard equipment |
Size and structure customization |
special environment |
Material and structure matching |
For standard and non-standard projects, product configuration can be carried out based on the installation size, target air volume, wind speed, filtration level, control method and actual use environment.
FFU is a kind of clean air equipment that combines a fan, air filter, box and control functions. The fan drives the air through the HEPA or ULPA filter, and then sends the filtered air into the target clean area.
FFU is mainly used to continuously provide filtered air to clean rooms, clean sheds, production equipment and local clean areas.
Common FFU can be configured with HEPA according to project requirements, and some high-cleaning applications can also be configured with ULPA. The specific filtration level needs to be determined based on cleanliness requirements and process conditions.
FFU is an air filtration device with fan power, while HEPA is an air filter and can be used as a filter component in FFU.
FFU is widely used in clean rooms and clean areas. EFU is more structurally designed based on the local cleanliness requirements of the equipment end. The final decision needs to be based on the installation space, air volume and equipment structure.
Some FFUs can achieve speed adjustment through corresponding fans and control systems. The specific speed adjustment method needs to be determined according to the product configuration.
Can. Multiple FFUs can use centralized control or computer group control according to the project scale to achieve partition, start-stop, speed and operating status management.
There is no fixed period that applies to all projects. The service life of the filter is related to factors such as ambient particle concentration, operating time, air volume, resistance changes, and maintenance management, and should be judged based on the actual operating status.
no. The wind speed needs to be determined comprehensively based on the cleanliness level, production process, equipment requirements, noise, energy consumption and system design.
Non-standard size matching can be carried out according to the project installation space, air volume, filter and structural requirements. The specific plan needs to be determined based on the actual project parameters.
If you need to quickly determine how to choose FFU, you can follow the following sequence:
Application scenario → Cleanliness requirements → Installation dimensions → Air volume and wind speed → HEPA/ULPA filtration level → System resistance → Fan matching → Drive mode → Control mode → Material and installation structure → Confirmation of complete machine parameters
For clean rooms, semiconductor equipment, electronic manufacturing, lithium batteries, photovoltaics, and other clean air projects, FFU needs to be configured based on actual working conditions, rather than determining products based only on one size or wind speed parameter.
Aili Industrial can focus on FFU, EFU, HEPA/ULPA filters and control systems, and match products according to the installation space, air volume, wind speed, filtration level, system resistance, control method and usage environment of the project.
FFU fan filter unit | EFU equipment side fan filter unit | HEPA/ULPA high efficiency filter | FFU group control system
What are the main components of FFU? Detailed explanation of fans, filters and control systems | How to choose FFU? What parameters are recommended to confirm before purchasing | What is the relationship between FFU air volume and wind speed | Should FFU choose AC, DC or EC | What is the difference between FFU and EFU