AIR MOVEMENT · MOTORS & DRIVES

Purification equipment fans
and motors

Selection and customization of EC centrifugal fans, impellers, motors and drive controls.

Aili Industry provides power components for FFU, EFU, air showers, clean workbench and air treatment equipment, and supports component procurement, replacement of existing fans and OEM matching.

Determine the working point based on the required air volume and pressure, and then select the configuration based on the installation space, power supply and speed adjustment method. When it is necessary to design the filter, box and control together, in-house R&D and manufacturing personnel can participate.

If there are no drawings, parameters or technical information, you are welcome to explain the purpose and usage environment first. We can assist in selection and design with our rich experience.

Aili Industrial EC190 metal volute centrifugal fan and motor product form display
Aili Industrial EC190 volute centrifugal fan (product form display)

EC centrifugal fans and power components series

Volute fans and impeller motor assemblies are installed differently. You can first understand the corresponding series according to the equipment air duct and structural space, and then determine the specific model.

Product form display of Aili Industrial EC143 volute centrifugal fan in two viewing directions
Aili Industrial EC143 volute centrifugal fan (form display)

EC143 volute centrifugal fan

The volute integrates the centrifugal impeller and motor, which is suitable for selection in combination with the internal air duct of the equipment. Focus on confirming the exit direction, mounting bracket and drive configuration.

Compact equipment air ducts, local air supply and replacement packages

Consult the EC143 series configuration of
Aili Industrial EC190 metal volute centrifugal fan and motor product form display
Aili Industrial EC190 volute centrifugal fan (form display)

EC190 volute centrifugal fan

The metal volute and air outlet flange are matched with the motor. Different suffixes correspond to different motor and drive configurations, which need to be identified with the complete model number.

Equipment air supply, flange connection and PWM supporting requirements

Consult the EC190 series configuration of
Product form display of Aili Industrial EC315 centrifugal impeller, inlet guide ring and independent motor
Aili Industrial EC315 centrifugal impeller and motor (form display)

EC315 centrifugal impeller and motor

The combination of impeller, motor and controller can be selected around the space, filter resistance and operating speed of FFU and other purification equipment.

FFU power components, equipment boxes and filtration accessories

Consult EC315 series configuration of
Product form display of Aili Industrial EC400 series impeller, motor, mounting plate and controller component combinations
Aili Industrial EC400 series power components (form display)

EC400 series power components

The impeller, motor, mounting plate and controller are combined according to the specific model. The mounting plate, guide structure and box air path should be considered together.

Purification air supply unit, power components and complete machine research and development supporting equipment

Consult EC400 series configuration

The series name is used to find the product, and the full model number and its suffix are used to identify the configuration. The display diagram illustrates the product or component form, and the actual scope of supply is determined by the confirmed drawings and configuration orders.

Common models and electronic control configuration reference

The following table lists some existing sample configurations to facilitate identification of series and model suffixes. The air volume and pressure need to be selected separately based on the corresponding curve and the actual working point.

Series complete model sample power supply sample power (W) matching controller speed regulation mode
EC143AILIGY-EC143H103N8P1A-1220V/50Hz75YJ-19AStepless speed regulation
EC190AILIGY-EC190H86N8P1A-2220V/50Hz90XF-19-40SPWM
EC190AILIGY-EC190H86N8P1A-2B220V/50Hz35XF-12-20SPWM
EC315AILIGY-EC315H68N8P1A-1A220V/50Hz55EC315-1300Stepless speed regulation
EC315AILIGY-EC315H68N8P1A-1F220V/50Hz118EC315-1500Stepless speed regulation
EC400AILIGY-EC400H68N8P1A-1220V/50Hz100EC400-1100Stepless speed regulation

The power column follows the sample label value and does not infer the equipment power consumption or motor shaft output based on this. When ordering, Aili Industrial will provide confirmation information of the corresponding model, and clearly define the power supply, power caliber, drive and terminals.

The selection is based on the operating point, not the two maximum values

After the fan is installed in the equipment, the actual air volume depends on the combination of fan performance and system resistance. Restricted air intake, elbows, filters and internal shielding will all cause changes in operating conditions.

Air volume and corresponding pressure are confirmed in pairs

First explain the target air volume and the pressure conditions that need to be overcome at this air volume. The maximum air volume and maximum pressure usually correspond to different states and cannot be combined into a rated operating point.

The pressure caliber is consistent with the test boundary

Static pressure, total pressure and static pressure available outside the whole machine should be stated separately. The pressure data on the curve needs to correspond to the equipment's air inlet and outlet connections, measurement location and test status.

The influence of the conditions that need to be explained on the selection of Aili Industrial Support Confirmation
of Filtration and Air PathThe actual air volume is affected by resistance, air duct and box structure during the initial and maintenance stages of the filter.Select the power configuration based on the target operating point, and consider
the operation and measurement range of the operating adjustment range.Power supply, speed or control settings, air conditions and test boundaries affect data comparabilityPerformance curves, input power and noise data provide
replacement and modification according to corresponding models and conditions.The same size and power do not mean the same performance. Existing equipment may also have local air intake restrictions.Evaluate replacement direction based on legacy model, field structure, and usage issues

If there is no air volume or pressure data for the time being, you can first explain the purpose of the equipment, the existing fans and the problems you want to solve. Aili Industry will assist in sorting out the selection criteria.

Motors and drives are matched according to the operation mode of the equipment.

Fan speed regulation involves not only the motor and drive, but also the control logic of the customer's equipment. When confirming an interface, you should also look at the power supply, signal definitions, and actual operation.

Motor, impeller and drive matching

Impeller load, target speed, start-stop method and operating period all influence motor selection. The motor rated parameters, drive capacity and operating point input power should be confirmed separately.

Look at the power supply and EC name separately

EC describes the electronic commutation method, and it cannot be judged based on this that the input must be low-voltage DC. The sample configuration listed on this page indicates 220V, 50Hz, and the actual input is based on the driver and wiring information of the model.

Aili industrial motor manufacturing process
Aili industrial motor R&D and manufacturing (actual manufacturing photos)
Interface requirement confirmation content
PWM or analog speed regulationControl voltage, PWM frequency and duty cycle range, signal common terminal, speed response and signal loss status
start, stop and running feedbackStart/stop logic, form of operation or fault feedback, electrical ratings, and handling of equipment master control
RS485 communication with equipmentInterface electrical definition, protocol, address, baud rate and data table; the same connector appearance does not mean compatibility with
single machine, group or whole machine controlAili Industrial evaluates the controller, wiring harness and software matching scope based on the number of equipment and usage methods.

When 0–10V, PWM, RS485 or other interfaces are required, please describe the device control requirements. Functions and interfaces are evaluated based on the selected model and are not considered standard for every fan.

Installation drawings should cover air inlet and outlet, fixing and maintenance conditions

Overall dimensions are only part of the installation conditions. If the fan is too close to the box, the diversion structure is inappropriate, or the fixing method is changed, air supply, noise and vibration may be affected.

parts Points of concern when installing and replacing
: the air inlet and guide ringMaintain an appropriate space on the air inlet side; the guide ring matches the impeller inlet, and the position and clearance are determined according to the drawings to confirm
the air outlet and connection.The air outlet direction, flange, air duct section and adjacent turns of the volute, together with the actual equipment air path, are used to evaluate
the connection between the motor and the impeller.The shaft end, mounting hole, fastening, rotation direction and rotation clearance are corresponding to avoid selecting based only on appearance.
supports and vibrations Support stiffness, fixed points, vibration damping parts and transportation fixation are designed according to the equipment structure. After trial installation, check the operating status
of the drive heat dissipation and wiring harness.Reserve space for heat dissipation, wiring, fixation and maintenance of the controller, and
arrange maintenance and subsequent replacement of power supply and control lines according to corresponding data.Confirm the removal direction, tool space, cable disconnection position and replacement model identification method

Size, air path and control changes are handled in the same configuration

Aili Industrial can carry out non-standard assessments focusing on equipment installation, operation objectives and procurement scope, and support the matching of fans, motors and related control components.

Structure and installation

Discuss the supporting structure around the equipment opening, volute outlet, mounting plate, fixing method and wiring harness path, taking into account assembly and subsequent disassembly.

Motor and performance

Evaluate the impeller, motor, speed and drive combination based on the target air volume, pressure and operating mode, and review the performance simultaneously when the structure changes.

Control and linkage

Correlate speed regulation, start-stop, and operation feedback with main equipment signals, and clarify the interfaces between fans, controllers, wiring harnesses, and customer equipment.

Samples and batches

Discuss prototypes, trial assembly and verification arrangements as needed, and use confirmed drawings, configurations, markings and inspection requirements for subsequent manufacturing.

When you need to purchase motors, impellers or control components separately, you are also welcome to contact Aili Industrial to explain the scope of supply. There are no drawing parameters, so you can start with the actual use.

Aili Industrial's motor, fan and complete machine manufacturing capabilities

Aili Industrial has a manufacturing base of 30,000 square meters. Its R&D and manufacturing cover motors, fans, control system software and hardware, air filters, sheet metal processing, complete machine assembly and testing. For power component matching, these links can work together around the same equipment requirements.

In-house R&D and manufacturing of motors and fans

The selection of motor and impeller revolves around the same operating point. When changes in speed, drive or structure occur, the impact on performance and installation can be directly assessed.

Filtration, air duct and box are designed together

When matching FFU, EFU or air treatment equipment, the filter resistance, air supply area, fan position and maintenance structure are jointly determined to reduce the number of components and then adjust the interface after each component is selected.

Direct connection between control software and hardware

Equipment and control personnel jointly confirm speed control signals, operating logic, fault feedback and communication requirements to facilitate the implementation of prototype adjustments into actual components and software.

Changes link manufacturing and cost accounting

Using the same set of validation data internally for part, sheet metal, and assembly changes helps reduce turnaround waits and retests. Configuration comparisons take into account component procurement, assembly man-hours and ongoing maintenance.

Aili industrial motor manufacturing process
Aili Industrial Motor R&D and Manufacturing
Aili industrial fan inspection station
Aili Industrial Fan Inspection
Aili industrial control system operation and detection interface
Aili Industrial Control System Inspection
Aili industrial air filter production equipment and workshop
Aili Industrial Air Filter Production
Aili Industrial sheet metal bending production station
Aili Industrial Sheet Metal Processing
Aili industrial purification equipment assembly production line
Aili Industrial Purification Equipment Assembly

According to the purpose of the equipment, determine the supporting points of power and control

The same series of fans installed in different equipment may have different air paths, filter resistance, operating settings and maintenance conditions. Selection needs to be based on specific equipment conditions.

FFU and clean air supply

The working point is determined based on the filter resistance, box air path and air supply area, and then connected to single machine or group operation.

EFU and equipment internal air supply

Pay attention to the installation height, equipment openings, internal shielding, key air supply locations and main equipment control interfaces.

Air shower room and clean workbench

According to the corresponding air duct, work area air supply and start-stop operation requirements, noise, maintenance and structural installation are assessed respectively.

Fan box and air handling equipment

The selection is based on filtration and other functional sections, pipeline connections, equipment space and external requirements, and the overall machine performance is confirmed based on the complete configuration.

Parts procurement and complete machine matching, communication according to required scope

This page focuses on fans, motors and drive components. When you need a complete clean air supply or air treatment equipment, you can learn more about the corresponding products and confirm the supply boundary with Aili Industrial.

From purpose to confirmation information

Understand usage requirements Evaluate models and interfaces Trial installation and verification on demand Confirm specifications and delivery

There is no need to prepare all the information before starting a consultation. Existing labels, photos, curves or drawings can be sent via WeChat 905745196 or email nancy@ailigy.com ; Ailigy Industry will provide feedback on selection or design suggestions based on the actual environment and needs.

Frequently Asked Questions about Fans and Motors

The following instructions are for preliminary selection and communication. When it comes to specific wiring, size and performance, please refer to the confirmation information of the corresponding model.

Can the fan, motor or impeller be purchased separately?

You can contact Aili Industrial to explain the required parts and usage. Independent components need to be evaluated based on conditions such as shaft end, fixation method, load, power supply and drive, and can also be matched with the controller and installation structure.

Are all EC fans connected to low voltage DC?

EC describes the electronic commutation method, and the input power depends on the specific drive configuration. The samples listed on this page are 220V, 50Hz. The wiring should be confirmed according to the corresponding model information. You cannot judge based on the name 'DC' or 'EC' alone.

If the model suffix is ​​different, will it affect replacement?

May correspond to motor, speed, power, drive or other configuration changes. When replacing, it is recommended to use complete model identification and judge based on curves, installation diagrams and interface data. Do not just compare series names such as EC143 and EC315.

Can the air volume and pressure on the fan sample be reached at the same time?

It depends on whether they belong to the same working point on the same curve. The maximum air volume and maximum pressure usually correspond to different states, and the model should be selected based on the corresponding pressure under the target air volume and actual test conditions.

Will the air volume necessarily increase if I switch to a more powerful motor?

The air volume also depends on the impeller, rotation speed, air path and system resistance. After changing the motor or drive, you need to re-evaluate the connection structure, working point and operating status. You cannot judge based on the power alone.

Can PWM, 0–10V or RS485 interfaces be used?

You can explain the signal and operation requirements of the main equipment to Aili Industrial, and we will evaluate the controller and wiring harness according to the specific model. Signal voltage, PWM frequency, communication protocol, terminal definition and feedback logic need to be confirmed separately and are not uniformly standard for all models.

The connectors have the same appearance, can they be directly connected to the original controller?

Electrical definitions and control logic need to be checked. Pins, signal levels, protocols, power and loss of signal status may be different, and the same connector appearance does not mean direct compatibility.

I already have a fan but do not have a complete model number. How can I inquire about replacement?

You can first send photos of the label, appearance, installation location and wiring, and describe the current usage. If you don’t have these information, you can contact us first and Aili Industrial will help sort out the conditions you need to know later.

How to obtain fan curves and installation drawings?

Contact Aili Industrial to explain the proposed series or equipment usage. We will provide corresponding information based on the specific configuration and confirm the model suffix, curve conditions, installation interface and wiring version. WeChat 905745196, email nancy@ailigy.com .

Can Aili Industrial cooperate with non-standard design of equipment?

The evaluation can be carried out based on the working point, installation space, air path, power supply and control requirements. Motor, fan, control, filter and structural personnel can participate together to discuss samples, trial assembly and batch matching as needed.

Can I contact you if I don’t have drawings, parameters or technical information?

sure. Just talk about where the equipment is used, the actual environment and the problems you want to solve. Aili Industry will combine its rich R&D and manufacturing experience to help sort out power configuration and interface requirements, and assist in selection and design.

What conditions are needed to compare the energy consumption of two types of fans?

The electrical input power should be compared under the same target air volume, pressure caliber and corresponding operating conditions, and the speed adjustment method and operating period should be considered. Nameplate power or no-load status cannot alone represent the power consumption of the equipment during use.

Welcome to contact Aili Industry to inquire about fans, motors and equipment matching

You can contact us for the purchase of standard products, replacement of existing parts, non-standard design and OEM batch matching.

Even if there are no drawings, parameters or technical information, you can first introduce the actual use environment and requirements. Aili Industry will rely on its rich R&D and manufacturing experience to help sort out the selection conditions and provide feedback on model, installation or control supporting suggestions.

to WeChat
905745196
mailbox
nancy@ailigy.com
factory
0563-6915989 / 6915859
Suzhou contact number
0512-63211760 / 61698502
mobile phone
13646258112
18913703898
Aili Industrial develops and manufactures FFU, EFU, HEPA/ULPA air filters, high-efficiency air supply vents, fan boxes and other clean air equipment. Relying on motors, fans, control systems, filters and complete machine supporting capabilities, we provide selection and customization support for clean room and production equipment projects.

Join a global perspective

Get the latest industry white papers and technology updates.
© Suzhou Aili Industrial Co., Ltd. All rights reserved.